Early results of a high friction surface coated uncemented socket in revision hip arthroplasty.


Journal

Hip international : the journal of clinical and experimental research on hip pathology and therapy
ISSN: 1724-6067
Titre abrégé: Hip Int
Pays: United States
ID NLM: 9200413

Informations de publication

Date de publication:
Nov 2020
Historique:
pubmed: 6 7 2019
medline: 9 3 2021
entrez: 6 7 2019
Statut: ppublish

Résumé

Revision hip arthroplasty with high friction trabecular metal sockets has resulted in good medium-term results. Many manufacturers have therefore introduced higher friction coatings to their implants to meet a growing demand for similar implants. The Pinnacle Gription was introduced in 2007 as an evolution of the standard Pinnacle socket. This study aimed to assess the early results of this socket in a revision setting. Between August 2009 and December 2016, the Gription socket was used in 146 revision hip replacements. The mean age was 63 (19-88) years. Defects were classified as Paprosky Grade 2 in 71(2A [28], 2B [19], 2C [24]) and grade 3 in 20 (3A [18], 3B [2]). Bearing combinations were ceramic-on-ceramic in 23, metal-on-polyethylene in 71, ceramic-on-polyethylene in 52. Screws were used in 112 cases, impaction bone grafting in 34 and metal augments in 1 case. Radiographs were analysed for progressive radiolucent lines and migration. Mean follow-up was 43.5 (range 25-62) months. There were 6 re-revisions (2 for deep infection, 2 for recurrent dislocation and 2 for aseptic loosening). None of the other cases had evidence of socket migration or progressive radiolucent lines. There were no intraoperative or postoperative periprosthetic fractures. The crude survivorship for all-cause failure was 95.8% and the survivorship for aseptic loosening was 98.6%. at 43.5 months follow-up. This is the largest reported series of Gription socket use in revision arthroplasty and demonstrates encouraging early results. We therefore advocate the continued cautious use of this implant.

Sections du résumé

BACKGROUND BACKGROUND
Revision hip arthroplasty with high friction trabecular metal sockets has resulted in good medium-term results. Many manufacturers have therefore introduced higher friction coatings to their implants to meet a growing demand for similar implants. The Pinnacle Gription was introduced in 2007 as an evolution of the standard Pinnacle socket. This study aimed to assess the early results of this socket in a revision setting.
METHODS METHODS
Between August 2009 and December 2016, the Gription socket was used in 146 revision hip replacements. The mean age was 63 (19-88) years. Defects were classified as Paprosky Grade 2 in 71(2A [28], 2B [19], 2C [24]) and grade 3 in 20 (3A [18], 3B [2]). Bearing combinations were ceramic-on-ceramic in 23, metal-on-polyethylene in 71, ceramic-on-polyethylene in 52. Screws were used in 112 cases, impaction bone grafting in 34 and metal augments in 1 case. Radiographs were analysed for progressive radiolucent lines and migration.
RESULTS RESULTS
Mean follow-up was 43.5 (range 25-62) months. There were 6 re-revisions (2 for deep infection, 2 for recurrent dislocation and 2 for aseptic loosening). None of the other cases had evidence of socket migration or progressive radiolucent lines. There were no intraoperative or postoperative periprosthetic fractures. The crude survivorship for all-cause failure was 95.8% and the survivorship for aseptic loosening was 98.6%. at 43.5 months follow-up.
CONCLUSIONS CONCLUSIONS
This is the largest reported series of Gription socket use in revision arthroplasty and demonstrates encouraging early results. We therefore advocate the continued cautious use of this implant.

Identifiants

pubmed: 31272233
doi: 10.1177/1120700019863002
doi:

Substances chimiques

Polyethylene 9002-88-4

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

739-744

Auteurs

Vinay Chacko (V)

Wrightington Hospital, Wigan, UK.

Pranshu Agrawal (P)

Wrightington Hospital, Wigan, UK.

Martyn L Porter (ML)

Wrightington Hospital, Wigan, UK.

Tim N Board (TN)

Wrightington Hospital, Wigan, UK.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH