Autograft-prosthesis composite use for a Vancouver type B1 periprosthetic femur fracture with pelvic acetabular component migration after bipolar hemiarthroplasty: A case report.
Acetabular prosthetic protrusion
Autograft
Bipolar hemiarthroplasty
Periprosthetic femur fracture
Reconstructive surgery
Journal
Trauma case reports
ISSN: 2352-6440
Titre abrégé: Trauma Case Rep
Pays: Netherlands
ID NLM: 101711730
Informations de publication
Date de publication:
Aug 2019
Aug 2019
Historique:
accepted:
16
06
2019
entrez:
11
7
2019
pubmed:
11
7
2019
medline:
11
7
2019
Statut:
epublish
Résumé
Bipolar hemiarthroplasty (BHA) is a commonly performed procedure for elderly patients with an intra-capsular fracture of the femoral neck. However, surgeons performing BHA worry about the rate of acetabular wear, and acetabular prosthesis protrusion can pose a challenging surgical problem. The number of periprosthetic femur fractures is expected to increase. Generally, well-fixed stems require open reduction and internal fixation (ORIF), whereas loose stems require revision arthroplasty. A 68-year-old Asian woman was admitted to our hospital. She had sustained a left displaced femoral neck fracture at the age of 58 years. BHA was performed via a posterior approach in another hospital. Ten years later, she presented with severe left hip pain following a low-energy fall. A radiograph of the hip joint demonstrated a Vancouver type B1 periprosthetic femur fracture with severe acetabular prosthetic protrusion. Single-stage reconstructive surgery was performed. A transgluteal approach was used, with distal extension to the fracture site of the femur. Acetabular reconstruction was performed using a Kerboull-type plate in combination with massive allografts for the large bone defects of the acetabulum. Regarding the femoral side, the proximal bone fragment and cementless stem that had been fixed were longitudinally opened with an osteotomy and separated. After that, the stem was changed to a cemented long stem and combined with the prior proximal bone fragments using cement and wires in an allograft-prosthesis composite technique (autograft-prosthesis composite). Although the standard treatment for Vancouver type B1 periprosthetic femur fractures is ORIF, it would have been difficult to reconstruct the hip joint solely with osteosynthesis because the femur was severely shortened by marked migration of the BHA. Single-stage reconstructive surgery using an autograft-prosthesis composite was effective treatment for a Vancouver type B1 periprosthetic femur fracture with concomitant severe acetabular prosthetic protrusion after BHA.
Identifiants
pubmed: 31289737
doi: 10.1016/j.tcr.2019.100213
pii: S2352-6440(19)30047-0
pii: 100213
pmc: PMC6593346
doi:
Types de publication
Case Reports
Langues
eng
Pagination
100213Déclaration de conflit d'intérêts
The authors declare that they have no conflicts of interest.
Références
Clin Orthop Relat Res. 2004 Mar;(420):169-75
pubmed: 15057093
J Bone Joint Surg Am. 2007 Mar;89 Suppl 2 Pt.1:68-79
pubmed: 17332126
Int Orthop. 2010 Mar;34(3):341-7
pubmed: 19418053
J Arthroplasty. 2010 Jun;25(4):594-9
pubmed: 19493654
J Arthroplasty. 2011 Jun;26(4):665.e25-8
pubmed: 20637558
Eur J Orthop Surg Traumatol. 2013 May;23(4):437-41
pubmed: 23412148
Int Orthop. 2015 Jan;39(1):1-5
pubmed: 25091328
Int Orthop. 2015 Oct;39(10):2005-10
pubmed: 26318883
J Orthop Case Rep. 2016 Jul-Aug;6(3):28-31
pubmed: 28116262
Instr Course Lect. 1995;44:293-304
pubmed: 7797866