Dual-layer spectral CT improves image quality of multiphasic pancreas CT in patients with pancreatic ductal adenocarcinoma.


Journal

European radiology
ISSN: 1432-1084
Titre abrégé: Eur Radiol
Pays: Germany
ID NLM: 9114774

Informations de publication

Date de publication:
Jan 2020
Historique:
received: 17 04 2019
accepted: 21 06 2019
revised: 30 05 2019
pubmed: 18 7 2019
medline: 13 3 2020
entrez: 18 7 2019
Statut: ppublish

Résumé

To evaluate the image quality and optimal energies of virtual monoenergetic images (VMIs) from dual-layer spectral detector computed tomography (DLCT) in multiphasic pancreatic CT and investigate whether low-keV VMI at the portal venous phase (PVP) provides sufficient tumor conspicuity and arterial depiction relative to conventional pancreatic parenchymal phase (PPP) images. Forty-eight patients with pancreatic ductal adenocarcinoma (PDAC) underwent contrast-enhanced DLCT during PPP and PVP. Conventional polyenergetic images (PEIs) and VMI at 40-100 keV (VMI Image noise for VMI DLCT-VMI improved the subjective and objective image quality in multiphasic pancreatic CT for patients with PDAC. Low-keV PVP imaging may yield diagnostically adequate tumor conspicuity and arterial assessment compared with polyenergetic PPP images. • Low-keV VMI from DLCT yields better subjective and objective image quality of multiphasic pancreas CT in comparison with conventional PEI for the assessment of pancreatic ductal adenocarcinoma. • Tumor conspicuity and depiction of peripancreatic vasculature were maximized at VMI

Identifiants

pubmed: 31312889
doi: 10.1007/s00330-019-06337-y
pii: 10.1007/s00330-019-06337-y
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

394-403

Références

Siegel RL, Miller KD, Jemal A (2019) Cancer statistics, 2019. CA Cancer J Clin 69:7–34
doi: 10.3322/caac.21551
Konstantinidis IT, Warshaw AL, Allen JN et al (2013) Pancreatic ductal adenocarcinoma: is there a survival difference for R1 resections versus locally advanced unresectable tumors? What is a “true” R0 resection? Ann Surg 257:731–736
doi: 10.1097/SLA.0b013e318263da2f
Somers I, Bipat S (2017) Contrast-enhanced CT in determining resectability in patients with pancreatic carcinoma: a meta-analysis of the positive predictive values of CT. Eur Radiol 27:3408–3435
doi: 10.1007/s00330-016-4708-5
Al-Hawary MM, Francis IR, Chari ST et al (2014) Pancreatic ductal adenocarcinoma radiology reporting template: consensus statement of the Society of Abdominal Radiology and the American Pancreatic Association. Radiology 270:248–260
doi: 10.1148/radiol.13131184
Zaky AM, Wolfgang CL, Weiss MJ, Javed AA, Fishman EK, Zaheer A (2017) Tumor-vessel relationships in pancreatic ductal adenocarcinoma at multidetector CT: different classification systems and their influence on treatment planning. Radiographics 37:93–112
doi: 10.1148/rg.2017160054
Marchegiani G, Todaro V, Boninsegna E et al (2018) Surgery after FOLFIRINOX treatment for locally advanced and borderline resectable pancreatic cancer: increase in tumour attenuation on CT correlates with R0 resection. Eur Radiol 28:4265–4273
doi: 10.1007/s00330-018-5410-6
Lu DS, Vedantham S, Krasny RM, Kadell B, Berger WL, Reber HA (1996) Two-phase helical CT for pancreatic tumors: pancreatic versus hepatic phase enhancement of tumor, pancreas, and vascular structures. Radiology 199:697–701
doi: 10.1148/radiology.199.3.8637990
Ichikawa T, Erturk SM, Sou H et al (2006) MDCT of pancreatic adenocarcinoma: optimal imaging phases and multiplanar reformatted imaging. AJR Am J Roentgenol 187:1513–1520
doi: 10.2214/AJR.05.1031
Prokesch RW, Chow LC, Beaulieu CF, Bammer R, Jeffrey RB Jr (2002) Isoattenuating pancreatic adenocarcinoma at multi-detector row CT: secondary signs. Radiology 224:764–768
doi: 10.1148/radiol.2243011284
Ishigami K, Yoshimitsu K, Irie H et al (2009) Diagnostic value of the delayed phase image for iso-attenuating pancreatic carcinomas in the pancreatic parenchymal phase on multidetector computed tomography. Eur J Radiol 69:139–146
doi: 10.1016/j.ejrad.2007.09.012
Falck C, Galanski M, Shin H-o (2010) Informatics in radiology: sliding-thin-slab averaging for improved depiction of low-contrast lesions with radiation dose savings at thin-section CT. Radiographics 30:317–326
doi: 10.1148/rg.302096007
Yanaga Y, Awai K, Nakayama Y et al (2007) Pancreas: patient body weight tailored contrast material injection protocol versus fixed dose protocol at dynamic CT. Radiology 245:475–482
doi: 10.1148/radiol.2452061749
Kondo H, Kanematsu M, Goshima S et al (2007) MDCT of the pancreas: optimizing scanning delay with a bolus-tracking technique for pancreatic, peripancreatic vascular, and hepatic contrast enhancement. AJR Am J Roentgenol 188:751–756
doi: 10.2214/AJR.06.0372
Marin D, Nelson RC, Barnhart H et al (2010) Detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase: effect of a low-tube-voltage, high-tube-current CT technique--preliminary results. Radiology 256:450–459
doi: 10.1148/radiol.10091819
Loizou L, Albiin N, Leidner B et al (2016) Multidetector CT of pancreatic ductal adenocarcinoma: effect of tube voltage and iodine load on tumour conspicuity and image quality. Eur Radiol 26:4021–4029
doi: 10.1007/s00330-016-4273-y
Lin X-Z, Machida H, RT IT et al (2014) CT of the pancreas: comparison of image quality and pancreatic duct depiction among model-based iterative, adaptive statistical iterative, and filtered back projection reconstruction techniques. Abdom Imaging 39:497–505
doi: 10.1007/s00261-014-0081-5
Yamamura S, Oda S, Utsunomiya D et al (2013) Dynamic computed tomography of locally advanced pancreatic cancer: effect of low tube voltage and a hybrid iterative reconstruction algorithm on image quality. J Comput Assist Tomogr 37:790–796
doi: 10.1097/RCT.0b013e318296db2b
Patel BN, Thomas JV, Lockhart ME, Berland LL, Morgan DE (2013) Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: optimization of energy level viewing significantly increases lesion contrast. Clin Radiol 68:148–154
doi: 10.1016/j.crad.2012.06.108
Frellesen C, Fessler F, Hardie AD et al (2015) Dual-energy CT of the pancreas: improved carcinoma-to-pancreas contrast with a noise-optimized monoenergetic reconstruction algorithm. Eur J Radiol 84:2052–2058
doi: 10.1016/j.ejrad.2015.07.020
Hardie AD, Picard MM, Camp ER et al (2015) Application of an advanced image-based virtual Monoenergetic reconstruction of dual source dual-energy CT data at low keV increases image quality for routine pancreas imaging. J Comput Assist Tomogr 39:716–720
doi: 10.1097/RCT.0000000000000276
McNamara MM, Little MD, Alexander LF, Carroll LV, Beasley TM, Morgan DE (2015) Multireader evaluation of lesion conspicuity in small pancreatic adenocarcinomas: complimentary value of iodine material density and low keV simulated monoenergetic images using multiphasic rapid kVp-switching dual energy CT. Abdom Imaging 40:1230–1240
doi: 10.1007/s00261-014-0274-y
Bellini D, Gupta S, Ramirez-Giraldo JC et al (2017) Use of a noise optimized monoenergetic algorithm for patient-size independent selection of an optimal energy level during dual-energy CT of the pancreas. J Comput Assist Tomogr 41:39–47
doi: 10.1097/RCT.0000000000000492
Bhosale P, Le O, Balachandran A, Fox P, Paulson E, Tamm E (2015) Quantitative and qualitative comparison of single-source dual-energy computed tomography and 120-kVp computed tomography for the assessment of pancreatic ductal adenocarcinoma. J Comput Assist Tomogr 39:907–913
doi: 10.1097/RCT.0000000000000295
Beer L, Toepker M, Ba-Ssalamah A et al (2019) Objective and subjective comparison of virtual monoenergetic vs. polychromatic images in patients with pancreatic ductal adenocarcinoma. Eur Radiol. https://doi.org/10.1007/s00330-019-06116-9
Kalisz K, Rassouli N, Dhanantwari A, Jordan D, Rajiah P (2018) Noise characteristics of virtual monoenergetic images from a novel detector-based spectral CT scanner. Eur J Radiol 98:118–125
doi: 10.1016/j.ejrad.2017.11.005
Nagayama Y, Nakaura T, Oda S et al (2018) Dual-layer DECT for multiphasic hepatic CT with 50 percent iodine load: a matched-pair comparison with a 120 kVp protocol. Eur Radiol 28:1719–1730
doi: 10.1007/s00330-017-5114-3
Sellerer T, Noel PB, Patino M et al (2018) Dual-energy CT: a phantom comparison of different platforms for abdominal imaging. Eur Radiol 28:2745–2755
doi: 10.1007/s00330-017-5238-5
Christner JA, Braun NN, Jacobsen MC, Carter RE, Kofler JM, McCollough CH (2012) Size-specific dose estimates for adult patients at CT of the torso. Radiology 265:841–847
doi: 10.1148/radiol.12112365
Hickethier T, Iuga AI, Lennartz S et al (2018) Virtual monoenergetic images from a novel dual-layer spectral detector computed tomography scanner in portal venous phase: adjusted window settings depending on assessment focus are essential for image interpretation. J Comput Assist Tomogr 42:350–356
doi: 10.1097/RCT.0000000000000711
Almeida RR, Lo GC, Patino M, Bizzo B, Canellas R, Sahani DV (2018) Advances in pancreatic CT imaging. AJR Am J Roentgenol 211:52–66
doi: 10.2214/AJR.17.18665
Sakabe D, Funama Y, Taguchi K et al (2018) Image quality characteristics for virtual monoenergetic images using dual-layer spectral detector CT: comparison with conventional tube-voltage images. Phys Med 49:5–10
doi: 10.1016/j.ejmp.2018.04.388
Nagayama Y, Iyama A, Oda S et al (2019) Dual-layer dual-energy computed tomography for the assessment of hypovascular hepatic metastases: impact of closing k-edge on image quality and lesion detectability. Eur Radiol 29:2837–2847
doi: 10.1007/s00330-018-5789-0
Grosse Hokamp N, Obmann VC, Kessner R et al (2018) Improved visualization of hypodense liver lesions in virtual monoenergetic images from spectral detector CT: proof of concept in a 3D-printed phantom and evaluation in 74 patients. Eur J Radiol 109:114–123
doi: 10.1016/j.ejrad.2018.11.001
Nagayama Y, Nakaura T, Oda S et al (2018) Dual-layer detector CT of chest, abdomen, and pelvis with a one-third iodine dose: image quality, radiation dose, and optimal monoenergetic settings. Clin Radiol 73:1058.e1021–1058.e1029
Brook OR, Gourtsoyianni S, Brook A, Siewert B, Kent T, Raptopoulos V (2013) Split-bolus spectral multidetector CT of the pancreas: assessment of radiation dose and tumor conspicuity. Radiology 269:139–148
doi: 10.1148/radiol.13121409
Hickethier T, Byrtus J, Hauger M et al (2018) Utilization of virtual mono-energetic images (MonoE) derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans. Eur J Radiol 99:28–33
doi: 10.1016/j.ejrad.2017.12.007
Lohofer FK, Kaissis GA, Koster FL et al (2018) Improved detection rates and treatment planning of head and neck cancer using dual-layer spectral CT. Eur Radiol 28:4925–4931
doi: 10.1007/s00330-018-5511-2
Zopfs D, Lennartz S, Laukamp K et al (2018) Improved depiction of atherosclerotic carotid artery stenosis in virtual monoenergetic reconstructions of venous phase dual-layer computed tomography in comparison to polyenergetic reconstructions. Eur J Radiol 100:36–42
doi: 10.1016/j.ejrad.2018.01.008
Fletcher JG, Wiersema MJ, Farrell MA et al (2003) Pancreatic malignancy: value of arterial, pancreatic, and hepatic phase imaging with multi-detector row CT. Radiology 229:81–90
doi: 10.1148/radiol.2291020582

Auteurs

Yasunori Nagayama (Y)

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan. y.nagayama1980@gmail.com.

Shota Tanoue (S)

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan.

Taihei Inoue (T)

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan.

Seitaro Oda (S)

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan.

Takeshi Nakaura (T)

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan.

Daisuke Utsunomiya (D)

Department of Diagnostic Radiology, Yokohama City University Hospital, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan.

Yasuyuki Yamashita (Y)

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH