Compact Grating-Coupled Biosensor for the Analysis of Thrombin.

antifouling brushes aptamer biosensor blood plasma grating-coupled surface plasmon resonance point of care surface plasmon resonance thrombin

Journal

ACS sensors
ISSN: 2379-3694
Titre abrégé: ACS Sens
Pays: United States
ID NLM: 101669031

Informations de publication

Date de publication:
23 08 2019
Historique:
pubmed: 1 8 2019
medline: 30 7 2020
entrez: 1 8 2019
Statut: ppublish

Résumé

A compact optical biosensor for direct detection of thrombin in human blood plasma (HBP) is reported. This biosensor platform is based on wavelength spectroscopy of diffraction-coupled surface plasmons on a chip with a periodically corrugated gold film that carries an antifouling thin polymer layer consisting of poly[(

Identifiants

pubmed: 31364363
doi: 10.1021/acssensors.9b00827
doi:

Substances chimiques

Ligands 0
Polymers 0
Thrombin EC 3.4.21.5

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

2109-2116

Auteurs

Daria Kotlarek (D)

Biosensor Technologies , AIT-Austrian Institute of Technology GmbH , Konrad-Lorenz-Straße 24 , 3430 Tulln an der Donau , Austria.

Mariia Vorobii (M)

DWI - Leibniz Institute for Interactive Materials and Institute of Technical and Macromolecular Chemistry , RWTH Aachen University , Forckenbeckstraße 50 , 52074 Aachen , Germany.

Wojciech Ogieglo (W)

DWI - Leibniz Institute for Interactive Materials and Institute of Technical and Macromolecular Chemistry , RWTH Aachen University , Forckenbeckstraße 50 , 52074 Aachen , Germany.

Wolfgang Knoll (W)

Biosensor Technologies , AIT-Austrian Institute of Technology GmbH , Konrad-Lorenz-Straße 24 , 3430 Tulln an der Donau , Austria.

Cesar Rodriguez-Emmenegger (C)

DWI - Leibniz Institute for Interactive Materials and Institute of Technical and Macromolecular Chemistry , RWTH Aachen University , Forckenbeckstraße 50 , 52074 Aachen , Germany.

Jakub Dostálek (J)

Biosensor Technologies , AIT-Austrian Institute of Technology GmbH , Konrad-Lorenz-Straße 24 , 3430 Tulln an der Donau , Austria.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH