[Upper Airway Stimulation for obstructive sleep apnea-Can radiological position monitoring predict tongue motion one year after implantation? German version].

Die obere Atemwegsstimulation bei obstruktiver Schlafapnoe – Kann die radiologische Lage des Stimulation-Cuff die Zungenbewegung vorhersagen?
Hypoglossus nerve stimulation Interrater variability PAP failure Rating system Tongue protrusion

Journal

HNO
ISSN: 1433-0458
Titre abrégé: HNO
Pays: Germany
ID NLM: 2985099R

Informations de publication

Date de publication:
Sep 2019
Historique:
pubmed: 16 8 2019
medline: 29 10 2019
entrez: 16 8 2019
Statut: ppublish

Résumé

Tongue motion patterns (TMP) can influence the outcome of upper airway stimulation (UAS) in the treatment of obstructive sleep apnea (OSA). As a postoperative control the cuff position of the stimulation lead is monitored via X‑ray imaging. A multidimensional X‑ray assessment system was established and the association between these positional assessments and TMP was investigated 1 year after implantation. The study on TMP and the X‑ray assessments were carried out at a German ear nose and throat clinic as an implantation center. The TMPs were assessed under bipolar electrode configuration and were categorized according to the currently available literature as right-sided protrusion (RP), left-sided protrusion (LP), bilateral protrusion (BP) and mixed activation (MA). The X‑ray assessment was carried out in five dimensions: the position relative to the mandible and hyoid, cuff steepness in the lateral view of the neck, the cuff position based on the single electrode and the lead connection to the cuff in the anterior-posterior view. The analyses were performed by three raters with different medical backgrounds and knowledge regarding TMP. In approximately 60% of the patients the apnea-hypopnea index was reduced to below 15/h, 1 year after implantation. The most common TMPs were RP and BP (82.9%). The interrater variability of the X‑ray assessment was good except for one category. Furthermore, no relevant associations were found apart from the correlation between a favorable TMP and the cuff position with respect to the lateral position of the stimulation cable. Despite good interrater variability and convenient usage of the suggested X‑ray assessment system, this approach did not enable the identification of any associations, by which a TM and therefore a possible straightforward or complicated treatment pathway could be predicted. Attention should possibly be paid to a rotation of the cuff during implantation with a lateral position of the stimulation lead.

Sections du résumé

BACKGROUND BACKGROUND
Tongue motion patterns (TMP) can influence the outcome of upper airway stimulation (UAS) in the treatment of obstructive sleep apnea (OSA). As a postoperative control the cuff position of the stimulation lead is monitored via X‑ray imaging. A multidimensional X‑ray assessment system was established and the association between these positional assessments and TMP was investigated 1 year after implantation.
MATERIAL AND METHODS METHODS
The study on TMP and the X‑ray assessments were carried out at a German ear nose and throat clinic as an implantation center. The TMPs were assessed under bipolar electrode configuration and were categorized according to the currently available literature as right-sided protrusion (RP), left-sided protrusion (LP), bilateral protrusion (BP) and mixed activation (MA). The X‑ray assessment was carried out in five dimensions: the position relative to the mandible and hyoid, cuff steepness in the lateral view of the neck, the cuff position based on the single electrode and the lead connection to the cuff in the anterior-posterior view. The analyses were performed by three raters with different medical backgrounds and knowledge regarding TMP.
RESULTS RESULTS
In approximately 60% of the patients the apnea-hypopnea index was reduced to below 15/h, 1 year after implantation. The most common TMPs were RP and BP (82.9%). The interrater variability of the X‑ray assessment was good except for one category. Furthermore, no relevant associations were found apart from the correlation between a favorable TMP and the cuff position with respect to the lateral position of the stimulation cable.
CONCLUSION CONCLUSIONS
Despite good interrater variability and convenient usage of the suggested X‑ray assessment system, this approach did not enable the identification of any associations, by which a TM and therefore a possible straightforward or complicated treatment pathway could be predicted. Attention should possibly be paid to a rotation of the cuff during implantation with a lateral position of the stimulation lead.

Identifiants

pubmed: 31414154
doi: 10.1007/s00106-019-0715-6
pii: 10.1007/s00106-019-0715-6
doi:

Types de publication

Journal Article

Langues

ger

Sous-ensembles de citation

IM

Pagination

690-697

Références

N Engl J Med. 2014 Jan 9;370(2):139-49
pubmed: 24401051
Eur Respir J. 2015 Jan;45(1):129-38
pubmed: 25186270
Sleep Breath. 2016 May;20(2):553-60
pubmed: 26315466
Laryngoscope. 2016 Dec;126(12):2852-2858
pubmed: 27345949
Laryngoscope. 2016 Sep;126 Suppl 7:S12-6
pubmed: 27572119
Otolaryngol Head Neck Surg. 2017 Feb;156(2):378-384
pubmed: 28025918
Laryngoscope. 2017 Oct;127(10):E378-E383
pubmed: 28105667
Laryngoscope. 2018 Feb;128(2):509-515
pubmed: 28561345
Head Neck. 2017 Dec;39(12):2371-2380
pubmed: 28960569
Laryngoscope. 2018 Aug;128(8):1970-1976
pubmed: 29280488
Otolaryngol Head Neck Surg. 2018 Jul;159(1):194-202
pubmed: 29582703
Sleep. 2018 Apr 1;41(4):
pubmed: 29590480
J Thorac Dis. 2018 Sep;10(Suppl 26):S3131-S3134
pubmed: 30370096
Eur Respir J. 2019 Jan 3;53(1):null
pubmed: 30487205

Auteurs

A Steffen (A)

Klinik für Hals-Nasen- und Ohrenheilkunde, Universitätsklinikum Schleswig-Holstein, Universität zu Lübeck, Ratzeburger Allee 160, 23538, Lübeck, Deutschland. armin.steffen@uksh.de.

A S Wozny (AS)

Klinik für Hals-Nasen- und Ohrenheilkunde, Universitätsklinikum Schleswig-Holstein, Universität zu Lübeck, Ratzeburger Allee 160, 23538, Lübeck, Deutschland.

I R König (IR)

Institut für Medizinische Biometrie und Statistik, Universität zu Lübeck, Lübeck, Deutschland.

J-P Goltz (JP)

Klinik für Radiologie und Nuklearmedizin, Universitätsklinikum Schleswig-Holstein, Universität zu Lübeck, Lübeck, Deutschland.

B Wollenberg (B)

Klinik für Hals-Nasen- und Ohrenheilkunde, Universitätsklinikum Schleswig-Holstein, Universität zu Lübeck, Ratzeburger Allee 160, 23538, Lübeck, Deutschland.

K Hasselbacher (K)

Klinik für Hals-Nasen- und Ohrenheilkunde, Universitätsklinikum Schleswig-Holstein, Universität zu Lübeck, Ratzeburger Allee 160, 23538, Lübeck, Deutschland.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH