Method for improving the spatial resolution of narrow x-ray beam-based x-ray luminescence computed tomography imaging.
medical optics instrumentation
tomography
x-ray luminescence
Journal
Journal of biomedical optics
ISSN: 1560-2281
Titre abrégé: J Biomed Opt
Pays: United States
ID NLM: 9605853
Informations de publication
Date de publication:
08 2019
08 2019
Historique:
received:
13
05
2019
accepted:
30
07
2019
entrez:
21
8
2019
pubmed:
21
8
2019
medline:
27
10
2020
Statut:
ppublish
Résumé
X-ray luminescence computed tomography (XLCT) is an emerging hybrid imaging modality which has the potential for achieving both high sensitivity and spatial resolution simultaneously. For the narrow x-ray beam-based XLCT imaging, based on previous work, a spatial resolution of about double the x-ray beam size can be achieved using a translate/rotate scanning scheme, taking step sizes equal to the x-ray beam width. To break the current spatial resolution limit, we propose a scanning strategy achieved by reducing the scanning step size to be smaller than the x-ray beam size. We performed four sets of numerical simulations and a phantom experiment using cylindrical phantoms and have demonstrated that our proposed scanning method can greatly improve the XLCT-reconstructed image quality compared with the traditional scanning approach. In our simulations, by using a fixed x-ray beam size of 0.8 mm, we were able to successfully reconstruct six embedded targets as small as 0.5 mm in diameter and with the same edge-to-edge distances by using a scanning step as small as 0.2 mm which is a 1.6 times improvement in the spatial resolution compared with the traditional approach. Lastly, the phantom experiment further demonstrated the efficacy of our proposed method in improving the XLCT image quality, with all image quality metrics improving as the step size decreased.
Identifiants
pubmed: 31429215
pii: JBO-190153RR
doi: 10.1117/1.JBO.24.8.086002
pmc: PMC6698719
doi:
Types de publication
Journal Article
Research Support, N.I.H., Extramural
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
1-11Subventions
Organisme : NIBIB NIH HHS
ID : R01 EB026646
Pays : United States
Références
Appl Opt. 2014 Sep 1;53(25):5672-6
pubmed: 25321362
ACS Appl Mater Interfaces. 2017 Nov 22;9(46):39985-39993
pubmed: 29063752
Appl Opt. 2017 Apr 10;56(11):3010-3019
pubmed: 28414356
J Biomed Opt. 2011 Jun;16(6):066014
pubmed: 21721815
IEEE Trans Biomed Eng. 2018 Aug;65(8):1892-1895
pubmed: 29989958
Chem Mater. 2014 Mar 11;26(5):1881-1888
pubmed: 24803724
Opt Express. 2018 Sep 3;26(18):23233-23250
pubmed: 30184978
Proc SPIE Int Soc Opt Eng. 2019 Feb;10871:
pubmed: 32231401
J Biomed Opt. 2014 Apr;19(4):046002
pubmed: 24695846
IEEE Trans Med Imaging. 2017 Jan;36(1):225-235
pubmed: 27576245
Biomed Opt Express. 2015 Jun 23;6(7):2649-63
pubmed: 26203388
Med Phys. 2010 Aug;37(8):4011-8
pubmed: 20879562
Biomed Opt Express. 2014 Nov 12;5(12):4249-59
pubmed: 26623173
IEEE Trans Med Imaging. 2010 Dec;29(12):1992-9
pubmed: 20615807
J Xray Sci Technol. 2017;25(6):945-957
pubmed: 28598861
Med Phys. 2013 Mar;40(3):031111
pubmed: 23464291
Phys Med Biol. 2014 Jun 21;59(12):2901-12
pubmed: 24828748
Nanoscale. 2018 Jan 25;10(4):1607-1612
pubmed: 29323363
Opt Lett. 2010 Oct 15;35(20):3345-7
pubmed: 20967061
J Biomed Opt. 2017 Nov;22(11):1-11
pubmed: 29127693
Opt Lett. 2009 Oct 1;34(19):2933-5
pubmed: 19794772
Chem Commun (Camb). 2013 May 14;49(39):4319-21
pubmed: 23320256
Biomed Opt Express. 2016 Jun 03;7(7):2506-23
pubmed: 27446686
IEEE Trans Biomed Eng. 2018 Sep;65(9):2130-2133
pubmed: 29989945