Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise?
Journal
PloS one
ISSN: 1932-6203
Titre abrégé: PLoS One
Pays: United States
ID NLM: 101285081
Informations de publication
Date de publication:
2019
2019
Historique:
received:
02
03
2019
accepted:
02
08
2019
entrez:
23
8
2019
pubmed:
23
8
2019
medline:
5
3
2020
Statut:
epublish
Résumé
The aim of the present study was to assess the accuracy of heart rate to estimate energy cost during eight resistance exercises performed at low intensities: half squat, 45° inclined leg press, leg extension, horizontal bench press, 45° inclined bench press, lat pull down, triceps extension and biceps curl. 56 males (27.5 ± 4.9 years, 1.78 ± 0.06 m height, 78.67 ± 10.7 kg body mass and 11.4 ± 4.1% estimated body fat) were randomly divided into four groups of 14 subjects each. Two exercises were randomly assigned to each group and subjects performed four bouts of 4-min constant-intensity at each assigned exercise: 12%, 16%, 20% and 24% 1-RM. Exercise and intensity order were random. Each subject performed no more than 2 bouts in the same testing session. A minimum recovery of 24h was kept between sessions. During testing VO2 was measured with Cosmed K4b2 and heart rate was measured with Polar V800 monitor. Energy cost was calculated from mean VO2 during the last 30-s of each bout by using the energy equivalent 1 ml O2 = 5 calorie. Linear regressions with heart rate as predictor and energy cost as dependent variable were build using mean data from all subjects. Robustness of the regression lines was given by the scatter around the regression line (Sy.x) and Bland-Altman plots confirmed the agreement between measured and estimated energy costs. Significance level was set at p≤0.05. The regressions between heart rate and energy cost in the eight exercises were significant (p<0.01) and robustness was: half squat (Sy.x = 0,48 kcal·min-1), 45° inclined leg press (Sy.x = 0,54 kcal·min-1), leg extension (Sy.x = 0,59 kcal·min-1), horizontal bench press (Sy.x = 0,47 kcal·min-1), 45° inclined bench press (Sy.x = 0,54 kcal·min-1), lat pull down (Sy.x = 0,28 kcal·min-1), triceps extension (Sy.x = 0,08 kcal·min-1) and biceps curl (Sy.x = 0,13 kcal·min-1). We conclude that during low-intensity resistance exercises it is possible to estimate aerobic energy cost by wearable heart rate monitors with errors below 10% in healthy young trained males.
Identifiants
pubmed: 31437191
doi: 10.1371/journal.pone.0221284
pii: PONE-D-19-06143
pmc: PMC6705857
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
e0221284Commentaires et corrections
Type : ErratumIn
Déclaration de conflit d'intérêts
The authors have declared that no competing interests exist.
Références
Ergonomics. 2000 Oct;43(10):1578-92
pubmed: 11083138
Int J Sports Med. 2001 May;22(4):280-4
pubmed: 11414671
Respir Physiol Neurobiol. 2002 Nov 19;133(3):241-50
pubmed: 12425971
Med Sci Sports Exerc. 2004 Aug;36(8):1433-9
pubmed: 15292754
Appl Physiol Nutr Metab. 2006 Aug;31(4):414-22
pubmed: 16900231
Med Sci Sports Exerc. 1991 May;23(5):636-40
pubmed: 2072844
Med Sci Sports Exerc. 2011 Jul;43(7):1334-59
pubmed: 21694556
J Strength Cond Res. 2013 Apr;27(4):1091-100
pubmed: 22692106
Int J Sports Med. 2015 May;36(5):357-64
pubmed: 25607522
Int J Sports Med. 2015 May;36(5):414-8
pubmed: 25700097
PLoS One. 2017 Jul 24;12(7):e0181311
pubmed: 28742112
Med Sci Sports Exerc. 2018 Mar;50(3):624-633
pubmed: 29189666
Br J Nutr. 1978 Nov;40(3):497-504
pubmed: 718832
Eur J Appl Physiol Occup Physiol. 1995;71(5):405-8
pubmed: 8565971