The Role of 18F-Fluorodeoxyglucose Positron-Emission Tomography/Computed Tomography in the Diagnosis of Postoperative Hardware-Related Spinal Infections.
Adult
Aged
Female
Fluorodeoxyglucose F18
Humans
Male
Middle Aged
Positron Emission Tomography Computed Tomography
/ methods
Postoperative Complications
/ diagnostic imaging
Prosthesis-Related Infections
/ diagnostic imaging
Radiopharmaceuticals
Reproducibility of Results
Retrospective Studies
Sensitivity and Specificity
Spine
/ diagnostic imaging
Journal
The Israel Medical Association journal : IMAJ
ISSN: 1565-1088
Titre abrégé: Isr Med Assoc J
Pays: Israel
ID NLM: 100930740
Informations de publication
Date de publication:
Aug 2019
Aug 2019
Historique:
entrez:
2
9
2019
pubmed:
2
9
2019
medline:
11
9
2019
Statut:
ppublish
Résumé
Implant-related spinal infections are a surgical complication associated with high morbidity. Due to infection, hardware removal may be necessary, which could lead to pseudarthrosis and the loss of stability and alignment. To evaluate the accuracy and diagnostic value of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (18F-FDG PET/CT) in the workup of patients with suspected implant-related infections of the spine and to assess the clinical impact of PET/CT results on the management of these infections. The study included nine consecutive patients with a history of spinal surgery who underwent PET/CT for evaluation of suspected spinal implant related infection. All imaging studies were performed between January 2011 and December 2013. All 18F-FDG PET/CT scans were performed on an 8 slice PET/CT following an 18F-FDG injection. Images were scored both visually and semi-quantitatively by a radiology expert. Results were compared to additional imaging studies when available, which were correlated to clinical and bacteriological findings allowing calculation of sensitivity, specificity and accuracy. Among the patients, five experienced hardware-related spinal infection. 18F-FDG PET/CT sensitivity was 80%, specificity 100%, and accuracy 88.9%. One scan produced a false negative; however, a second PET/CT scan revealed an infection. PET/CT was found to be valuable for the diagnosis of postoperative hardware-related spinal infection, especially when other imaging modalities were uninformative or inconclusive. As such, PET/CT could be useful for management of infection treatment.
Sections du résumé
BACKGROUND
BACKGROUND
Implant-related spinal infections are a surgical complication associated with high morbidity. Due to infection, hardware removal may be necessary, which could lead to pseudarthrosis and the loss of stability and alignment.
OBJECTIVES
OBJECTIVE
To evaluate the accuracy and diagnostic value of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (18F-FDG PET/CT) in the workup of patients with suspected implant-related infections of the spine and to assess the clinical impact of PET/CT results on the management of these infections.
METHODS
METHODS
The study included nine consecutive patients with a history of spinal surgery who underwent PET/CT for evaluation of suspected spinal implant related infection. All imaging studies were performed between January 2011 and December 2013. All 18F-FDG PET/CT scans were performed on an 8 slice PET/CT following an 18F-FDG injection. Images were scored both visually and semi-quantitatively by a radiology expert. Results were compared to additional imaging studies when available, which were correlated to clinical and bacteriological findings allowing calculation of sensitivity, specificity and accuracy.
RESULTS
RESULTS
Among the patients, five experienced hardware-related spinal infection. 18F-FDG PET/CT sensitivity was 80%, specificity 100%, and accuracy 88.9%. One scan produced a false negative; however, a second PET/CT scan revealed an infection.
CONCLUSIONS
CONCLUSIONS
PET/CT was found to be valuable for the diagnosis of postoperative hardware-related spinal infection, especially when other imaging modalities were uninformative or inconclusive. As such, PET/CT could be useful for management of infection treatment.
Substances chimiques
Radiopharmaceuticals
0
Fluorodeoxyglucose F18
0Z5B2CJX4D
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM