Reliability of ultrasonographic measurements of bovine sole structures in relation to sole horn thickness, measured by computed tomography, and sole horn hardness.
bovine claw
computed tomography
sole horn thickness
ultrasonography
Journal
Journal of dairy science
ISSN: 1525-3198
Titre abrégé: J Dairy Sci
Pays: United States
ID NLM: 2985126R
Informations de publication
Date de publication:
Nov 2019
Nov 2019
Historique:
received:
08
06
2018
accepted:
03
06
2019
pubmed:
16
9
2019
medline:
24
12
2019
entrez:
16
9
2019
Statut:
ppublish
Résumé
The goal of the present study was to determine the effect of sole horn thickness (SHT) and sole horn hardness (SHD) on ultrasonographic visualization of sole structures in the inner and outer claws of 150 Holstein-Friesian cows, and to evaluate different ultrasound frequencies for this purpose. Ultrasonographic views of the sole structure were considered complete when 3 echogenic lines, representing the ventral surface of the sole horn, the borders of the sole horn and soft-tissue layer, and the ventral surface of the distal phalanx, were seen. The proportion of complete ultrasonographic views of the sole structures, designated as the ultrasonographic visualization proportion (UVP), and the measurement errors of SHT were evaluated by comparing images from computed tomography (CT) and ultrasonography. The latter images were generated using 3 different probes, frequencies of 6.5 and 5.0 MHz, and 2 different ultrasound machines (#1 and #2) to assess the apex, middle, and heel regions of the claws. The UVP were 60.8 to 77.9% for the 6.5-MHz probe in ultrasound machine #1 (probe A), which were lower than those (>90%) for both the 5.0-MHz probe in ultrasound machine #1 (probe B) and the 5.0-MHz probe in ultrasound machine #2 (probe C). The UVP was significantly lower in claws with an SHD ≥50 units than in claws with an SHD <40 or 40 to <50 units (UVP: 77.1% compared with 93.7 and 91.4%, respectively) when measured with probe B. In claws with an SHT <10 mm, the UVP was significantly lower when SHD was ≥50 units compared with <40 or 40 to >50 units; the values were 69.0% versus 91.3 and 85.9%, respectively, for probe A, and 89.7% versus 100 and 100%, respectively, for probe B. When SHT were measured by either probes A or B in ultrasound machine #1, the proportions of claws in which ultrasonographic values were within a ±1 mm range compared with the values obtained by CT were 84.9 to 91.3% for CT-determined SHT <5 mm, 66.7 to 71.9% for CT-determined SHT 5 to <7 mm, 28.9 to 51.2% for CT-determined SHT 7 to <10 mm, and 6.2 to 19.7% for CT-determined SHT ≥10 mm. The data indicated that increased SHT was associated with a decrease in ultrasonographic measurement accuracy. In claws with an SHT <5 mm, the high proportion of ultrasonographic values that were accurate within a ±1 mm range suggests that this imaging modality would be useful in cows with thin soles.
Identifiants
pubmed: 31521343
pii: S0022-0302(19)30788-X
doi: 10.3168/jds.2018-15175
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
10105-10118Informations de copyright
Copyright © 2019 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.