A real-time Monte Carlo tool for individualized dose estimations in clinical CT.
Journal
Physics in medicine and biology
ISSN: 1361-6560
Titre abrégé: Phys Med Biol
Pays: England
ID NLM: 0401220
Informations de publication
Date de publication:
04 11 2019
04 11 2019
Historique:
pubmed:
21
9
2019
medline:
14
5
2020
entrez:
21
9
2019
Statut:
epublish
Résumé
The increasing awareness of the adverse effects associated with radiation exposure in computed tomography (CT) has necessesitated the quantification of dose delivered to patients for better risk assessment in the clinic. The current methods for dose quantification used in the clinic are approximations, lacking realistic models for the irradiation conditions utilized in the scan and the anatomy of the patient being imaged, which limits their relevance for a particular patient. The established gold-standard technique for individualized dose quantification uses Monte Carlo (MC) simulations to obtain patient-specific estimates of organ dose in anatomically realistic computational phantoms to provide patient-specific estimates of organ dose. Although accurate, MC simulations are computationally expensive, which limits their utility for time-constrained applications in the clinic. To overcome these shortcomings, a real-time GPU-based MC tool based on FDA's MC-GPU framework was developed for patient and scanner-specific dosimetry in the clinic. The tool was validated against (1) AAPM's TG-195 reference datasets and (2) physical measurements of dose acquired using TLD chips in adult and pediatric anthropomorphic phantoms. To demonstrate its utility towards providing individualized dose estimates, it was integrated with an automatic segmentation method for generating patient-specific models, which were then used to estimate patient- and scanner-specific organ doses for a select population of 50 adult patients using a clinically relevant CT protocol. The organ dose estimates were compared to corresponding dose estimates from a previously validated MC method based on Penelope. The dose estimates from our MC tool agreed within 5% for all organs (except thyroid) tabulated by TG-195 and within 10% for all TLD locations in the adult and pediactric phantoms, across all validation cases. Compared against Penelope, the organ dose estimates agreed within 3% on average for all organs in the patient population study. The average run duration for each patient was estimated at 23.79 s, representing a significant speedup (~700×) over existing non-parallelized MC methods. The accuracy of dose estimates combined with a significant improvement in execution times suggests a feasible solution utilizing the proposed MC tool for real-time individualized dosimetry in the clinic.
Identifiants
pubmed: 31539892
doi: 10.1088/1361-6560/ab467f
pmc: PMC7050822
mid: NIHMS1563832
doi:
Types de publication
Journal Article
Research Support, N.I.H., Extramural
Langues
eng
Sous-ensembles de citation
IM
Pagination
215020Subventions
Organisme : NIBIB NIH HHS
ID : R01 EB001838
Pays : United States
Références
Med Phys. 2010 Apr;37(4):1816-25
pubmed: 20443504
Med Phys. 2013 Apr;40(4):043701
pubmed: 23556927
Med Phys. 2012 Jun;39(6):2985-96
pubmed: 22755683
Radiology. 2017 Jun;283(3):739-748
pubmed: 28092496
Med Phys. 2011 Jan;38(1):397-407
pubmed: 21361208
Med Phys. 2008 May;35(5):1859-69
pubmed: 18561661
Radiology. 2012 Dec;265(3):666-8
pubmed: 23175540
Med Phys. 2012 Nov;39(11):6550-71
pubmed: 23127050
Radiology. 2017 Jun;283(3):624-627
pubmed: 28514218
Radiology. 2012 Aug;264(2):567-80
pubmed: 22692035
Phys Med Biol. 2016 May 21;61(10):3935-54
pubmed: 27119974
Med Phys. 2009 Nov;36(11):4878-80
pubmed: 19994495
Phys Med Biol. 2013 Dec 21;58(24):8755-68
pubmed: 24301136
Med Phys. 2015 Oct;42(10):5679-91
pubmed: 26429242
Br J Radiol. 2012 Dec;85(1020):e1316-7
pubmed: 23175496
AJR Am J Roentgenol. 2013 Dec;201(6):1283-90
pubmed: 24261368
Eur Radiol. 2008 Apr;18(4):759-72
pubmed: 18066555
Phys Med Biol. 2014 Aug 21;59(16):4525-48
pubmed: 25069102
Med Phys. 2010 Sep;37(9):4902-15
pubmed: 20964209
IEEE Trans Med Imaging. 2019 Jun;38(6):1457-1465
pubmed: 30561344
Conf Proc IEEE Eng Med Biol Soc. 2017 Jul;2017:560-563
pubmed: 29059934
Med Phys. 2009 Dec;36(12):5654-64
pubmed: 20095278