Comparison of specimen adequacy and diagnostic accuracy of a 25-gauge and 22-gauge needle in endobronchial ultrasound-guided transbronchial needle aspiration.

Bronchoscopy endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) lymph node

Journal

Journal of thoracic disease
ISSN: 2072-1439
Titre abrégé: J Thorac Dis
Pays: China
ID NLM: 101533916

Informations de publication

Date de publication:
Aug 2019
Historique:
entrez: 28 9 2019
pubmed: 29 9 2019
medline: 29 9 2019
Statut: ppublish

Résumé

Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the preferred diagnostic modality for sampling mediastinal and hilar lymph nodes (LNs). The conventional needle used for sampling is either a 21-gauge (21G) or 22-gauge (22G). A 25-gauge (25G) needle has recently been introduced with little known regarding its efficacy. A retrospective study was conducted on patients referred for EBUS-TBNA who had LNs sampled using a 25G or 22G needle. A propensity score matching analysis was performed. After matching the groups, each LN was assessed for adequacy and final diagnosis. Non-diagnostic and benign lymphoid specimens were compared with repeat biopsy findings or long-term clinical and radiological follow-up. A total of 158 LNs were included. An adequate sample was obtained in 92.4% (73/79) in the 25G group and 92.4% (73/79) in the 22G group (P=1). The 25G group diagnosed benign lymphoid tissue in 82.3% (65/79), granuloma in 7.6% (6/79) and malignancy in 2.5% (2/79). Six lymph nodes in the 25G group were non-diagnostic (7.6%). The 22G group diagnosed benign lymphoid tissue in 83.5% (66/79), granuloma in 3.8% (3/79) and malignancy in 5.1% (4/79). Six lymph nodes in the 22G group were non-diagnostic (7.6%). The sensitivity, specificity, negative predictive value (NPV) and diagnostic accuracy in the 25G group was 88.9% (95% CI, 51.8-99.7%), 100% (95% CI, 92.1-100%), 97.8% (95% CI, 87.6-99.7%) and 98.2% (95% CI, 90.1-100%), respectively. The sensitivity, specificity, NPV and diagnostic accuracy in the 22G group was 77.8% (95% CI, 40-97.2%), 100% (95% CI, 86.8-100%), 92.9% (95% CI, 79.3-97.8%) and 94.3% (95% CI, 80.8-99.3%), respectively. The 25G and 22G group were comparable in diagnostic accuracy (P=0.7). The 25G and 22G needle achieve comparable specimen adequacy and diagnostic accuracy in EBUS-TBNA.

Sections du résumé

BACKGROUND BACKGROUND
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the preferred diagnostic modality for sampling mediastinal and hilar lymph nodes (LNs). The conventional needle used for sampling is either a 21-gauge (21G) or 22-gauge (22G). A 25-gauge (25G) needle has recently been introduced with little known regarding its efficacy.
METHODS METHODS
A retrospective study was conducted on patients referred for EBUS-TBNA who had LNs sampled using a 25G or 22G needle. A propensity score matching analysis was performed. After matching the groups, each LN was assessed for adequacy and final diagnosis. Non-diagnostic and benign lymphoid specimens were compared with repeat biopsy findings or long-term clinical and radiological follow-up.
RESULTS RESULTS
A total of 158 LNs were included. An adequate sample was obtained in 92.4% (73/79) in the 25G group and 92.4% (73/79) in the 22G group (P=1). The 25G group diagnosed benign lymphoid tissue in 82.3% (65/79), granuloma in 7.6% (6/79) and malignancy in 2.5% (2/79). Six lymph nodes in the 25G group were non-diagnostic (7.6%). The 22G group diagnosed benign lymphoid tissue in 83.5% (66/79), granuloma in 3.8% (3/79) and malignancy in 5.1% (4/79). Six lymph nodes in the 22G group were non-diagnostic (7.6%). The sensitivity, specificity, negative predictive value (NPV) and diagnostic accuracy in the 25G group was 88.9% (95% CI, 51.8-99.7%), 100% (95% CI, 92.1-100%), 97.8% (95% CI, 87.6-99.7%) and 98.2% (95% CI, 90.1-100%), respectively. The sensitivity, specificity, NPV and diagnostic accuracy in the 22G group was 77.8% (95% CI, 40-97.2%), 100% (95% CI, 86.8-100%), 92.9% (95% CI, 79.3-97.8%) and 94.3% (95% CI, 80.8-99.3%), respectively. The 25G and 22G group were comparable in diagnostic accuracy (P=0.7).
CONCLUSIONS CONCLUSIONS
The 25G and 22G needle achieve comparable specimen adequacy and diagnostic accuracy in EBUS-TBNA.

Identifiants

pubmed: 31559072
doi: 10.21037/jtd.2019.04.20
pii: jtd-11-08-3643
pmc: PMC6753430
doi:

Types de publication

Journal Article

Langues

eng

Pagination

3643-3649

Déclaration de conflit d'intérêts

Conflicts of Interest: B Young is a consultant for Pinnacle Biologics, Auris Surgical Robotics and ProVation. The other authors have no conflicts of interest to declare.

Références

J Clin Oncol. 2008 Jul 10;26(20):3346-50
pubmed: 18519953
J Gastroenterol Hepatol. 2009 Mar;24(3):384-90
pubmed: 19032453
Endoscopy. 2009 May;41(5):445-8
pubmed: 19418399
Ultrasound Med Biol. 2009 Aug;35(8):1271-7
pubmed: 19540652
Respir Med. 2009 Dec;103(12):1796-800
pubmed: 19674882
Gastroenterol Res Pract. 2009;2009:546390
pubmed: 19997511
Chest. 2010 Oct;138(4):790-4
pubmed: 20154073
Respirology. 2011 Jan;16(1):90-4
pubmed: 20920141
Ann Thorac Surg. 2011 Aug;92(2):428-32; discussion 433
pubmed: 21592456
Chest. 2011 Dec;140(6):1550-1556
pubmed: 21636663
Am J Respir Crit Care Med. 2012 Jun 15;185(12):1316-22
pubmed: 22505743
Endoscopy. 2013;45(2):86-92
pubmed: 23307148
Ann Nucl Med. 2013 May;27(4):400-5
pubmed: 23400394
Chest. 2013 Apr;143(4):1036-1043
pubmed: 23632441
Chest. 2013 May;143(5 Suppl):e211S-e250S
pubmed: 23649440
Gastroenterol Hepatol (N Y). 2013 Jun;9(6):352-63
pubmed: 23935542
J Thorac Oncol. 2013 Nov;8(11):1438-1444
pubmed: 24128714
Eur J Cardiothorac Surg. 2014 May;45(5):787-98
pubmed: 24578407
Cancer Cytopathol. 2015 Feb;123(2):92-7
pubmed: 25186645
BMJ Open Respir Res. 2014 May 31;1(1):e000040
pubmed: 25478187
Cancer Cytopathol. 2015 Jun;123(6):362-72
pubmed: 25931443
Chest. 2016 Mar;149(3):816-35
pubmed: 26402427
Respir Investig. 2016 Jan;54(1):29-34
pubmed: 26718142
Endosc Ultrasound. 2016 Jan-Feb;5(1):43-8
pubmed: 26879166
Clin Lung Cancer. 2018 May;19(3):230-238.e2
pubmed: 29277564
J Bronchology Interv Pulmonol. 2018 Oct;25(4):264-268
pubmed: 29771776

Auteurs

Christopher Di Felice (C)

University Hospitals Cleveland Medical Center, Department of Pulmonary, Critical Care and Sleep Medicine, Cleveland, Ohio, USA.

Benjamin Young (B)

University Hospitals Cleveland Medical Center, Department of Pulmonary, Critical Care and Sleep Medicine, Cleveland, Ohio, USA.

Maroun Matta (M)

University Hospitals Cleveland Medical Center, Department of Pulmonary, Critical Care and Sleep Medicine, Cleveland, Ohio, USA.

Classifications MeSH