Outcomes of 188 Proximal Humeral Fractures Treated with a Dedicated External Fixator with Follow-up Ranging from 2 to 12 Years.
Journal
The Journal of bone and joint surgery. American volume
ISSN: 1535-1386
Titre abrégé: J Bone Joint Surg Am
Pays: United States
ID NLM: 0014030
Informations de publication
Date de publication:
18 Sep 2019
18 Sep 2019
Historique:
entrez:
1
10
2019
pubmed:
1
10
2019
medline:
18
2
2020
Statut:
ppublish
Résumé
The treatment of a displaced proximal humeral fracture is still a matter of controversy. Minimally invasive techniques are considered promising options. The purpose of this study was to report outcomes at medium to long-term follow-up after surgical treatment with pins stabilized with an external fixator. A total of 235 patients (average age, 64 years [95% confidence interval (CI), 62 to 65 years]) were treated with closed or open reduction and fixation with pins stabilized by an external fixator specifically designed for proximal humeral fractures. The pins were inserted using a "pins-crossing-fracture" or a "pins-bridging-fracture" technique. One hundred and eighty-eight patients had a minimum radiographic and clinical follow-up of 2 years. Outcomes were assessed using the Oxford Shoulder Score (OSS), the subjective shoulder value (SSV), a visual analog scale (VAS) for pain, and, for 155 patients, the Constant score. Eighty-one (43%) of the 188 patients had a 2-part fracture, 60 (32%) had a 3-part fracture, and 47 (25%) had a 4-part fracture. The reduction was performed with percutaneous maneuvers in 120 shoulders or a deltopectoral approach, in 68. The external fixator was applied using a "pins-crossing-fracture" technique in 133 shoulders and using a "pins-bridging-fracture" technique in 55. At last follow-up, mean clinical scores were as follows: OSS, 42.6 (95% CI, 42 to 44); SSV, 85.5 (95% CI, 83 to 88); and VAS for pain, 1 (95% CI, 0.7 to 1.2). The complication rate at 3 months was 16% (37 of 235). The most frequent complication was pin-track infection (19 of 235, 8%). A total of 50 patients had ≥1 complication (50 of 188, 27%) and 6 (3%) underwent revision surgery. More complications were observed with the "pins-crossing-fracture" technique. In our experience, the use of the external fixator has been a valuable option in the treatment of proximal humeral fractures. The complication and revision rates were acceptable. Most of the complications encountered were manageable without revision surgery. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Sections du résumé
BACKGROUND
BACKGROUND
The treatment of a displaced proximal humeral fracture is still a matter of controversy. Minimally invasive techniques are considered promising options. The purpose of this study was to report outcomes at medium to long-term follow-up after surgical treatment with pins stabilized with an external fixator.
METHODS
METHODS
A total of 235 patients (average age, 64 years [95% confidence interval (CI), 62 to 65 years]) were treated with closed or open reduction and fixation with pins stabilized by an external fixator specifically designed for proximal humeral fractures. The pins were inserted using a "pins-crossing-fracture" or a "pins-bridging-fracture" technique. One hundred and eighty-eight patients had a minimum radiographic and clinical follow-up of 2 years. Outcomes were assessed using the Oxford Shoulder Score (OSS), the subjective shoulder value (SSV), a visual analog scale (VAS) for pain, and, for 155 patients, the Constant score.
RESULTS
RESULTS
Eighty-one (43%) of the 188 patients had a 2-part fracture, 60 (32%) had a 3-part fracture, and 47 (25%) had a 4-part fracture. The reduction was performed with percutaneous maneuvers in 120 shoulders or a deltopectoral approach, in 68. The external fixator was applied using a "pins-crossing-fracture" technique in 133 shoulders and using a "pins-bridging-fracture" technique in 55. At last follow-up, mean clinical scores were as follows: OSS, 42.6 (95% CI, 42 to 44); SSV, 85.5 (95% CI, 83 to 88); and VAS for pain, 1 (95% CI, 0.7 to 1.2). The complication rate at 3 months was 16% (37 of 235). The most frequent complication was pin-track infection (19 of 235, 8%). A total of 50 patients had ≥1 complication (50 of 188, 27%) and 6 (3%) underwent revision surgery. More complications were observed with the "pins-crossing-fracture" technique.
CONCLUSIONS
CONCLUSIONS
In our experience, the use of the external fixator has been a valuable option in the treatment of proximal humeral fractures. The complication and revision rates were acceptable. Most of the complications encountered were manageable without revision surgery.
LEVEL OF EVIDENCE
METHODS
Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Identifiants
pubmed: 31567802
doi: 10.2106/JBJS.18.00734
pii: 00004623-201909180-00005
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1654-1661Commentaires et corrections
Type : CommentIn