Establishment of a Therapeutic Ratio for Gamma Knife Radiosurgery of Trigeminal Neuralgia: The Critical Importance of Biologically Effective Dose Versus Physical Dose.
BED
Biologically effective dose
Radiation dose
Radiosurgery
Therapeutic ratio
Trigeminal neuralgia
Journal
World neurosurgery
ISSN: 1878-8769
Titre abrégé: World Neurosurg
Pays: United States
ID NLM: 101528275
Informations de publication
Date de publication:
Feb 2020
Feb 2020
Historique:
received:
28
06
2019
revised:
01
10
2019
accepted:
03
10
2019
pubmed:
14
10
2019
medline:
5
3
2020
entrez:
14
10
2019
Statut:
ppublish
Résumé
How variations of treatment time affect the safety and efficacy of Gamma Knife (GK) radiosurgery is a matter of considerable debate. With the relative simplicity of treatment planning for trigeminal neuralgia (TN), this question has been addressed in a group of these patients. Using the concept of the biologically effective dose (BED), the effect of the two key variables, dose and treatment time, were considered. A retrospective analysis was performed of 408 TN cases treated from 1997 to 2010. Treatment involved the use of a single 4 mm isocenter. If conditions allowed, the isocenter was placed at a median distance of 7.5 mm from the emergence of the trigeminal nerve from the brain stem. The effects were assessed in terms of the incidence of the complication, hypoesthesia, and in terms of efficacy using the incidence of pain free after 30 days and 1 and 2 years. These responses were evaluated with respect to both the physical dose and the BED, the latter using a bi-exponential repair model. RE-evaluation showed that the prescription doses, at the 100% isodose, varied from 75 to 97.9 Gy, delivered in 25-135 minutes. The relationship between the physical dose and the incidence of hypoesthesia was not significant; the overall incidence was ∼20%. However, a clear relationship was found between the BED and the incidence of hypoesthesia, with the incidence increasing from <5% after a BED of ∼1800 Gy These results strongly suggest that safety and efficacy might be better achieved by prescribing a specific BED instead of a physical dose. A dose and time to BED conversion table has been prepared to enable iso-BED prescriptions. This finding could dramatically change dose-planning strategies in the future. However, this concept requires validation for other indications for which more complex dose planning is required.
Identifiants
pubmed: 31606504
pii: S1878-8750(19)32636-1
doi: 10.1016/j.wneu.2019.10.021
pii:
doi:
Types de publication
Comparative Study
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e204-e213Informations de copyright
Copyright © 2019 Elsevier Inc. All rights reserved.