Embolization using hydrogel-coated coils for pulmonary arteriovenous malformations.
Arteriovenous malformation
Embolization
Lung
Pulmonary arteriovenous fistulas
Journal
Diagnostic and interventional imaging
ISSN: 2211-5684
Titre abrégé: Diagn Interv Imaging
Pays: France
ID NLM: 101568499
Informations de publication
Date de publication:
Mar 2020
Mar 2020
Historique:
received:
16
08
2019
revised:
14
10
2019
accepted:
22
10
2019
pubmed:
15
11
2019
medline:
5
1
2021
entrez:
15
11
2019
Statut:
ppublish
Résumé
To prospectively evaluate the efficacy and safety of embolization using hydrogel-coated coils for the treatment of pulmonary arteriovenous malformations (PAVMs). The outcomes of 21 PAVMs in 19 patients (3 men and 16 women; mean age, 58.8±15.2 [SD] years; age range 14-78 years) treated by venous sac embolization (VSE) with additional feeding artery embolization were prospectively evaluated. For VSE, using one or more 0.018-inch hydrogel-coated coils was mandatory. Recanalization and/or reperfusion were evaluated by pulmonary arteriography 1 year after embolization. The mean feeding artery and venous sac sizes were 4.0mm and 8.5mm, respectively. Embolization was successfully completed in 20/21 PAVMs, yielding a technical success rate of 95%. The feeding artery was also embolized in 17/20 successful PAVMs (85%). A technical failure occurred in one PAVM, where embolization was abandoned because of migration of one bare coil to the left ventricle. The mean numbers of hydrogel-coated coils and bare platinum detachable coils used for VSE were 3.3±2.1 (SD) (range, 1-8) and 4.4±3.9 (SD) (range, 1-17), respectively. The mean percentages of hydrogel-coated coils in number, length, and estimated volume were 42.9%, 33.3%, and 72.7% respectively. One patient with one PAVM was lost to follow-up after 3 months. Neither recanalization nor reperfusion was noted in the remaining 19 PAVMs (success rate, 19/19 [100%]). One grade 4 (coil migration) adverse event occurred, and it was treated without any sequelae. VSE using hydrogel-coated coils with additional feeding artery embolization is a safe and effective treatment for PAVM.
Identifiants
pubmed: 31722843
pii: S2211-5684(19)30237-2
doi: 10.1016/j.diii.2019.10.008
pii:
doi:
Substances chimiques
Coated Materials, Biocompatible
0
Hydrogels
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
129-135Informations de copyright
Copyright © 2019 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.