Optimizing HR-pQCT workflow: a comparison of bias and precision error for quantitative bone analysis.

Bone microarchitecture Bone mineral density Endocortical contour Error bias High-resolution peripheral quantitative computed tomography Precision

Journal

Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA
ISSN: 1433-2965
Titre abrégé: Osteoporos Int
Pays: England
ID NLM: 9100105

Informations de publication

Date de publication:
Mar 2020
Historique:
received: 25 07 2019
accepted: 28 10 2019
pubmed: 1 12 2019
medline: 4 3 2021
entrez: 1 12 2019
Statut: ppublish

Résumé

Manual correction of automatically generated contours for high-resolution peripheral quantitative computed tomography can be time consuming and introduces precision error. However, bias related to the automated protocol is unknown. This study provides insight into error bias that is present when using uncorrected contours and inter-operator precision error based on operator training. High-resolution peripheral quantitative computed tomography workflow includes manually correcting contours generated by the manufacturer's automated protocol. There is interest in minimizing corrections to save time and reduce precision error; however, bias related to the automated protocol is unknown. This study quantifies error bias when contours are uncorrected and identifies the impact of operator training on bias and precision error. Forty-five radii and tibiae scans across a representative range of bone density were analyzed using the automated and manually corrected contours of three operators, with training ranging from beginner to expert, and compared with a "ground truth" to estimate bias. Inter-operator precision was measured across operators. The tibia had greater error bias than the radius when contours were uncorrected, with compartmental bone mineral densities and cortical microarchitecture having greatest biases, which could have significant implications for interpretation of studies using this skeletal site. Bias and precision error were greatest when contours were corrected by the beginner operator; however, when this operator was removed, bias was no longer present and inter-operator precision was between 0.01 and 3.74% for all parameters except cortical porosity. These findings establish the need for manual correction and provide guidance on operator training needed to maximize workflow efficiency.

Identifiants

pubmed: 31784787
doi: 10.1007/s00198-019-05214-0
pii: 10.1007/s00198-019-05214-0
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

567-576

Références

IEEE Trans Med Imaging. 2004 Jul;23(7):903-21
pubmed: 15250643
J Bone Miner Res. 2017 Oct;32(10):2001-2009
pubmed: 28608571
Med Image Anal. 2015 Aug;24(1):205-219
pubmed: 26201875
J Clin Densitom. 2018 Apr - Jun;21(2):295-302
pubmed: 28256308
J Bone Miner Res. 2011 Jan;26(1):50-62
pubmed: 20593413
J Bone Miner Res. 2017 Jul;32(7):1514-1524
pubmed: 28294415
Calcif Tissue Int. 2018 Sep;103(3):252-265
pubmed: 29594493
Osteoporos Int. 1995;5(4):262-70
pubmed: 7492865
Bone. 2012 Jun;50(6):1304-10
pubmed: 22445540
Bone. 2015 Oct;79:213-21
pubmed: 26079995
Phys Med Biol. 2015 Jun 7;60(11):4429-47
pubmed: 25988718
J Bone Miner Res. 2017 Jun;32(6):1243-1251
pubmed: 28276092
J Bone Miner Res. 2016 Nov;31(11):2041-2047
pubmed: 27192388
J Bone Miner Res. 2017 Jul;32(7):1525-1536
pubmed: 28326606
Bone. 2007 Oct;41(4):505-15
pubmed: 17693147
Osteoporos Int. 2009 Oct;20(10):1683-94
pubmed: 19152051
Osteoporos Int. 2016 Feb;27(2):789-96
pubmed: 26252976

Auteurs

D E Whittier (DE)

McCaig Institute for Bone and Joint Health and Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.

A N Mudryk (AN)

McCaig Institute for Bone and Joint Health and Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.

I D Vandergaag (ID)

McCaig Institute for Bone and Joint Health and Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.

L A Burt (LA)

McCaig Institute for Bone and Joint Health and Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.

S K Boyd (SK)

McCaig Institute for Bone and Joint Health and Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada. skboyd@ucalgary.ca.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH