How Computational Modeling can Help to Predict Gas Transfer in Artificial Lungs Early in the Design Process.


Journal

ASAIO journal (American Society for Artificial Internal Organs : 1992)
ISSN: 1538-943X
Titre abrégé: ASAIO J
Pays: United States
ID NLM: 9204109

Informations de publication

Date de publication:
06 2020
Historique:
pubmed: 4 12 2019
medline: 12 1 2021
entrez: 3 12 2019
Statut: ppublish

Résumé

Wearable extracorporeal membrane oxygenation (ECMO) circuits may soon become a viable alternative to conventional ECMO treatment. Common device-induced complications, however, such as blood trauma and oxygenator thrombosis, must first be addressed to improve long-term reliability, since ambulatory patients cannot be monitored as closely as intensive care patients. Additionally, an efficient use of the membrane surface can reduce the size of the devices, priming volume, and weight to achieve portability. Both challenges are linked to the hemodynamics in the fiber bundle. While experimental test methods can often only provide global and time-averaged information, computational fluid dynamics (CFD) can give insight into local flow dynamics and gas transfer before building the first laboratory prototype. In this study, we applied our previously introduced micro-scale CFD model to the full fiber bundle of a small oxygenator for gas transfer prediction. Three randomized geometries as well as a staggered and in-line configuration were modeled and simulated with Ansys CFX. Three small laboratory oxygenator prototypes were built by stacking fiber segments unidirectionally with spacers between consecutive segments. The devices were tested in vitro for gas transfer with porcine blood in accordance with ISO 7199. The error of the predicted averaged CFD oxygen saturations of the random 1, 2, and 3 configurations relative to the averaged in-vitro data (over all samples and devices) was 2.4%, 4.6%, 3.1%, and 3.0% for blood flow rates of 100, 200, 300, and 400 ml/min, respectively. While our micro-scale CFD model was successfully applied to a small oxygenator with unidirectional fibers, the application to clinically relevant oxygenators will remain challenging due to the complex flow distribution in the fiber bundle and high computational costs. However, we will outline our future research priorities and discuss how an extended mass transfer correlation model implemented into CFD might enable an a priori prediction of gas transfer in full size oxygenators.

Identifiants

pubmed: 31789656
doi: 10.1097/MAT.0000000000001098
pii: 00002480-202006000-00017
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

683-690

Références

Bartlett RH. ECMO: the next ten years. The Egyptian journal of critical care medicine 2016.4: 7–10.
Bartlett RH, Deatrick KB. Current and future status of extracorporeal life support for respiratory failure in adults. Curr Opin Crit Care 2016.22: 80–85.
Haneya A, Philipp A, Foltan M, et al. First experience with the new portable extracorporeal membrane oxygenation system cardiohelp for severe respiratory failure in adults. Perfusion 2012.27: 150–155.
Philipp A, Arlt M, Amann M, et al. First experience with the ultra compact mobile extracorporeal membrane oxygenation system cardiohelp in interhospital transport. Interact Cardiovasc Thorac Surg 2011.12: 978–981.
Zhang T, Wei X, Bianchi G, et al. A novel wearable pump-lung device: in vitro and acute in vivo study. J Heart Lung Transplant 2012.31: 101–105.
Madhani SP, Frankowski BJ, Federspiel WJ. Fiber bundle design for an integrated wearable artificial lung. ASAIO J 2017.63: 631–636.
Taskin ME, Zhang T, Fraser KH, Griffith BP, Wu ZJ. Design optimization of a wearable artificial pump-lung device with computational modeling. Journal of Medical Devices 2012.6: 031009.
Zangrillo A, Landoni G, Biondi-Zoccai G, et al. A meta-analysis of complications and mortality of extracorporeal membrane oxygenation. Crit Care Resusc 2013.15: 172–178.
Zhang J, Taskin ME, Koert A, et al. Computational design and in vitro characterization of an integrated maglev pump-oxygenator. Artif Organs 2009.33: 805–817.
Gartner MJ, Wilhelm CR, Gage KL, Fabrizio MC, Wagner WR. Modeling flow effects on thrombotic deposition in a membrane oxygenator. Artif Organs 2000.24: 29–36.
Gage KL, Gartner MJ, Burgreen GW, Wagner WR. Predicting membrane oxygenator pressure drop using computational fluid dynamics. Artif Organs 2002.26: 600–607.
Funakubo A, Taga I, McGillicuddy JW, Fukui Y, Hirschl RB, Bartlett RH. Flow vectorial analysis in an artificial implantable lung. ASAIO J 2003.49: 383–387.
Gabelman A, Hwang ST. Hollow fiber membrane contactors. Journal of Membrane Science 1999.159: 61–106.
Zhang J, Nolan TDC, Zhang T, Griffith BP, Wu ZJ. Characterization of membrane blood oxygenation devices using computational fluid dynamics. Journal of Membrane Science 2007.288: 268–279.
Chan KY, Fujioka H, Bartlett RH, Hirschl RB, Grotberg JB. Pulsatile flow and mass transport over an array of cylinders: gas transfer in a cardiac-driven artificial lung. J Biomech Eng 2006.128: 85–96.
Zierenberg JR, Fujioka H, Cook KE, Grotberg JB. Pulsatile flow and oxygen transport past cylindrical fiber arrays for an artificial lung: computational and experimental studies. J Biomech Eng 2008.130: 031019.
Kaesler A, Rosen M, Schmitz-Rode T, Steinseifer U, Arens J. Computational modeling of oxygen transfer in artificial lungs. Artif Organs 2018.42: 786–799.
Hormes M, Borchardt R, Mager I, Rode TS, Behr M, Steinseifer U. A validated CFD model to predict O2 and CO2 transfer within hollow fiber membrane oxygenators. Int J Artif Organs 2011.34: 317–325.
Taskin ME, Fraser KH, Zhang T, Griffith BP, Wu ZJ. Micro-scale modeling of flow and oxygen transfer in hollow fiber membrane bundle. J Memb Sci 2010.362: 172–183.
Dierickx PW, de Wachter DS, Verdonck PR. Two-dimensional finite element model for oxygen transfer in cross-flow hollow fiber membrane artificial lungs. Int J Artif Organs 2001.24: 628–635.
Zhang J, Chen X, Ding J, Fraser KH, Taskin ME, Griffith BP, et al. Computational study of the blood flow in three types of 3D hollow fiber membrane bundles. J Biomech Eng. 2013.135: 121009.
Mazaheri AR, Ahmadi G. Uniformity of the fluid flow velocities within hollow fiber membranes of blood oxygenation devices. Artif Organs 2006.30: 10–15.
Low KW, van Loon R, Rolland SA, Sienz J. Pore-scale modeling of non-newtonian shear-thinning fluids in blood oxygenator design. J Biomech Eng 2016.138: 051001.
ELASTOSIL® RT 625 A/B, Wacker, data sheet, Accessed: 05/2019;. Available from: https://www.wacker.com/cms/de/products/product/product.jsp?product=13307.
Wickramasinghe S, Garcia J, Han B. Mass and momentum transfer in hollow fibre blood oxygenators. Journal of membrane science 2002.208: 247–256.
Wright J. Analysis of low reynolds number blood flow in a rectangular microchannel utilizing a two-phase eulerian-eulerian model and including a steady state oxygen-hemoglobin reaction approximation. Faculty of the Graduate School of The University of Texas at Arlington 2009.
Weissman MH, Mockros LF. Oxygen transfer to blood flowing in round tubes. Journal of the Engineering Mechanics Division 1967.93: 225–244.
Vaslef SN, Mockros LF, Cook KE, Leonard RJ, Sung JC, Anderson RW. Computer-assisted design of an implantable, intrathoracic artificial lung. Artif Organs 1994.18: 813–817.
Pacella HE, Eash HJ, Federspiel WJ. Darcy permeability of hollow fiber bundles used in blood oxygenation devices. J Memb Sci 2011.382: 238–242.
Madhani SP, D’Aloiso BD, Frankowski B, Federspiel WJ. Darcy permeability of hollow fiber membrane bundles made from membrana polymethylpentene fibers used in respiratory assist devices. ASAIO J 2016.62: 329–331.
Schlanstein PC, Limper A, Hesselmann F, Schmitz-Rode T, Steinseifer U, Arens J. Experimental method to determine anisotropic permeability of hollow fiber membrane bundles. Journal of Membrane Science 2018.546: 70–81.
Engelking, Larry R. Textbook of veterinary physiological chemistry. 2015. Burlington, MA: Academic Press/Elsevier, Print.

Auteurs

Andreas Kaesler (A)

From the Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH