Mechanical Energy Dissipation Through the Ossicular Chain and Inner Ear Using Laser Doppler Vibrometer Measurement of Round Window Velocity.


Journal

Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
ISSN: 1537-4505
Titre abrégé: Otol Neurotol
Pays: United States
ID NLM: 100961504

Informations de publication

Date de publication:
03 2020
Historique:
pubmed: 11 12 2019
medline: 15 4 2021
entrez: 11 12 2019
Statut: ppublish

Résumé

Round window velocity measurements should correlate closely with vibration measurements taken at proximal points along an intact chain over a set frequency range. These round window vibration measurements should be similar to the vibration measurements taken of the ossicles if mechanical energy is conserved through the vestibular organ. To date there has not been a study which compares vibratory velocity measurements through an intact ossicular chain to the level of the round window. This study attempted to quantify the degree of mechanical energy transmission and suspected dissipation through the ossicular chain and vestibular organ through incus, stapes, and round window velocity measurements in response to sound stimulus. Five thawed human temporal bones with intact ossicular chain and tympanic membrane underwent complete mastoidectomy and a facial recess approach. A laser Doppler vibrometer (LDV) was mounted on the operating microscope to measure vibration of incus, stapes, and round window in response to a sound stimulus within the external auditory canal. Sound stimulus frequencies ranged from 0.5 to 4 kHz at 90 dB SPL. Vibration velocity was measured across the frequency range for each incus, stapes, and round window. Vibration velocity curves obtained over the frequency range were similar for each of the bones with a notable resonant frequency around 2 kHz. The incus and stapes curve amplitudes were nearly identical with similar maximum velocity and frequency at which this maximal velocity was noted. Round window vibration velocity demonstrated a unique peak velocity. Transfer function measurements of the stapes and round window demonstrated markedly similar curves. The variation in velocity between temporal bones in response to the standardized stimulus was more dramatic in the round window measurements when compared with the incus and stapes. This study supports the concept that round window transfer function is equivalent to stapes footplate transfer function when subjected to the same acoustic stimuli. This study also demonstrates that the round window is a much more difficult target to measure when using LDV technology and improvements in experimental design are required to better understand round window physiology in relation to transfer of acoustic vibratory stimulus transferred throughout the middle ear. A complete and thorough understanding of the biophysical properties of the middle and inner ear are critical for optimal ossiculoplasty outcomes and the development of future ossicular prosthetics.

Sections du résumé

HYPOTHESIS
Round window velocity measurements should correlate closely with vibration measurements taken at proximal points along an intact chain over a set frequency range. These round window vibration measurements should be similar to the vibration measurements taken of the ossicles if mechanical energy is conserved through the vestibular organ.
BACKGROUND
To date there has not been a study which compares vibratory velocity measurements through an intact ossicular chain to the level of the round window. This study attempted to quantify the degree of mechanical energy transmission and suspected dissipation through the ossicular chain and vestibular organ through incus, stapes, and round window velocity measurements in response to sound stimulus.
METHODS
Five thawed human temporal bones with intact ossicular chain and tympanic membrane underwent complete mastoidectomy and a facial recess approach. A laser Doppler vibrometer (LDV) was mounted on the operating microscope to measure vibration of incus, stapes, and round window in response to a sound stimulus within the external auditory canal. Sound stimulus frequencies ranged from 0.5 to 4 kHz at 90 dB SPL.
RESULTS
Vibration velocity was measured across the frequency range for each incus, stapes, and round window. Vibration velocity curves obtained over the frequency range were similar for each of the bones with a notable resonant frequency around 2 kHz. The incus and stapes curve amplitudes were nearly identical with similar maximum velocity and frequency at which this maximal velocity was noted. Round window vibration velocity demonstrated a unique peak velocity. Transfer function measurements of the stapes and round window demonstrated markedly similar curves. The variation in velocity between temporal bones in response to the standardized stimulus was more dramatic in the round window measurements when compared with the incus and stapes.
CONCLUSIONS
This study supports the concept that round window transfer function is equivalent to stapes footplate transfer function when subjected to the same acoustic stimuli. This study also demonstrates that the round window is a much more difficult target to measure when using LDV technology and improvements in experimental design are required to better understand round window physiology in relation to transfer of acoustic vibratory stimulus transferred throughout the middle ear. A complete and thorough understanding of the biophysical properties of the middle and inner ear are critical for optimal ossiculoplasty outcomes and the development of future ossicular prosthetics.

Identifiants

pubmed: 31821262
doi: 10.1097/MAO.0000000000002509
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

e387-e391

Auteurs

Matthew Ryan (M)

Uniformed Services University of the Health Sciences, Bethesda, Maryland.

John Lally (J)

Division of Otolaryngology-Head and Neck Surgery, Department of Surgery, Brooke Army Medical Center, San Antonio, Texas.

Jason K Adams (JK)

Division of Otolaryngology-Head and Neck Surgery, Department of Surgery, Brooke Army Medical Center, San Antonio, Texas.

Sophie Higgins (S)

Uniformed Services University of the Health Sciences, Bethesda, Maryland.

Mostafa Ahmed (M)

Carl R. Darnall Army Medical Center, Fort Hood, Texas.

James Aden (J)

Division of Otolaryngology-Head and Neck Surgery, Department of Surgery, Brooke Army Medical Center, San Antonio, Texas.

Carlos Esquivel (C)

Department of Defense Hearing Center of Excellence, San Antonio, Texas.

Samuel A Spear (SA)

Division of Otolaryngology-Head and Neck Surgery, Department of Surgery, Brooke Army Medical Center, San Antonio, Texas.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH