The biomechanics of concussive helmet-to-ground impacts in the National Football league.


Journal

Journal of biomechanics
ISSN: 1873-2380
Titre abrégé: J Biomech
Pays: United States
ID NLM: 0157375

Informations de publication

Date de publication:
23 01 2020
Historique:
received: 07 10 2019
revised: 26 11 2019
accepted: 29 11 2019
pubmed: 16 12 2019
medline: 13 11 2020
entrez: 16 12 2019
Statut: ppublish

Résumé

This paper presents a detailed characterization of helmet-to-ground impacts in the National Football League. Video analysis was performed for 16 head-to-ground impacts that caused concussions. Average resultant closing velocity was 8.3 m/s at an angle nearly 45° to the surface. Preimpact rotational velocity of the helmet ranged from negligible to as high as 54.1 rad/s. Helmet impacts were concentrated on the posterior and lateral aspects. To study the interaction in greater detail, a helmeted anthropomorphic test device (ATD) was launched over a football field and fell to the ground in various impact conditions. Substantial decoupling between the helmet and the head was observed, such that the head rebounded within the helmet and underwent changes in linear and rotational motion greater than those of the helmet. Vertical helmet rebound was also observed; the helmet underwent a change in vertical velocity on average 24% greater than the vertical component of its closing velocity. Frictional interaction between the helmet and the ground surface caused the helmet to undergo an average horizontal change in velocity of 57% of the horizontal component of its closing velocity. Finally, the duration of a helmet-to-ground impact was generally in the range of 15 - 30 ms, suggesting that the impact surface provides little ride-down. Lengthening this duration could be beneficial both by reducing the peak linear and rotational acceleration and by shifting the impact toward a time regime where brain strain is related to rotational acceleration rather than rotational velocity.

Identifiants

pubmed: 31837745
pii: S0021-9290(19)30808-5
doi: 10.1016/j.jbiomech.2019.109551
pii:
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

109551

Informations de copyright

Copyright © 2019 Elsevier Ltd. All rights reserved.

Auteurs

Richard Kent (R)

Biomechanics Consulting and Research, LLC, USA; Center for Applied Biomechanics, University of Virginia, USA. Electronic address: rwk3c@virginia.edu.

Jason Forman (J)

Center for Applied Biomechanics, University of Virginia, USA.

Ann M Bailey (AM)

Biomechanics Consulting and Research, LLC, USA.

James Funk (J)

Biomechanics Consulting and Research, LLC, USA.

Chris Sherwood (C)

Biomechanics Consulting and Research, LLC, USA.

Jeff Crandall (J)

Biomechanics Consulting and Research, LLC, USA; Center for Applied Biomechanics, University of Virginia, USA.

Kristy B Arbogast (KB)

Center for Injury Research and Prevention, The Children's Hospital of Philadelphia, Philadelphia, PA, USA.

Barry S Myers (BS)

Duke University, Biomedical Engineering, Durham, NC, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH