Development of a total serum testosterone, androstenedione, 17-hydroxyprogesterone, 11β-hydroxyandrostenedione and 11-ketotestosterone LC-MS/MS assay and its application to evaluate pre-analytical sample stability.


Journal

Clinical chemistry and laboratory medicine
ISSN: 1437-4331
Titre abrégé: Clin Chem Lab Med
Pays: Germany
ID NLM: 9806306

Informations de publication

Date de publication:
28 04 2020
Historique:
received: 12 09 2019
accepted: 15 11 2019
pubmed: 12 1 2020
medline: 21 5 2021
entrez: 12 1 2020
Statut: ppublish

Résumé

Background Classically, serum testosterone (T) and androstenedione (A4) have been the mainstay for the biochemical assessment of hyperandrogenism. However, recent evidence suggests 11β-hydroxyandrostenedione (11OHA4) and 11-ketotestosterone (11KT) may also be important. Here, we describe the development of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for quantitation of total serum T, A4, 17-hydroxyprogesterone (17OHP), 11OHA4 and 11KT. In addition, we applied the method to assess pre-analytical stability. Methods An isotopically labelled internal standard was added to samples prior to supported liquid extraction (SLE). Extracts were analysed using LC-MS/MS to detect T/A4/17OHP/11OHA4 and 11KT along with their corresponding internal standards. Samples (n = 7) were collected from healthy volunteers (n = 14) and left incubated at 20 °C for up to 72 h. Tubes were retrieved at select time points, centrifuged, separated and frozen prior to analysis. Results The total run time was 4 min. For all analytes, intra- and inter-assay imprecision did not exceed 7.9% and 5.3%, respectively; matrix effects were negligible and mean recoveries ranged from 95.3 to 111.6%. The limits of quantitation (LOQs) were 0.25 nmol/L for T, A4 and 11OHA4, 0.50 nmol/L for 17OHP, and 0.24 nmol/L for 11KT. No significant change was observed in pre-centrifugation A4 or female T concentrations over 72 h. Significant increases (p < 0.01) in concentrations of 11KT, 17OHP, 11OHA4 and male T were observed after 2, 8, 12 and 24 h, respectively. Conclusions We developed a robust LC-MS/MS assay for the quantitation of total serum T/A4/17OHP/11OHA4 and 11KT. Applying the method to determine pre-analytical stability suggests samples requiring 11KT need separating from the cells within 2 h.

Identifiants

pubmed: 31926069
doi: 10.1515/cclm-2019-0959
pii: /j/cclm.ahead-of-print/cclm-2019-0959/cclm-2019-0959.xml
doi:
pii:

Substances chimiques

Testosterone 3XMK78S47O
Androstenedione 409J2J96VR
11-hydroxyandrostenedione 564-32-9
17-alpha-Hydroxyprogesterone 68-96-2
11-ketotestosterone KF38W1A85U

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

741-752

Auteurs

James M Hawley (JM)

Department of Clinical Biochemistry, Wythenshawe Hospital, Manchester NHS Foundation Trust, Manchester M23 9LT, UK.

Joanne E Adaway (JE)

Department of Clinical Biochemistry, Wythenshawe Hospital, Manchester NHS Foundation Trust, Manchester, UK.

Laura J Owen (LJ)

Department of Clinical Biochemistry, Salford Royal Hospital, Manchester, UK.

Brian G Keevil (BG)

Department of Clinical Biochemistry, Wythenshawe Hospital, Manchester NHS Foundation Trust, Manchester, UK.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH