Preprocedural computed tomography before cardiac implanted electronic device lead extraction: Indication, technique, and approach to interpretation.
computed tomography
imaging
implantable cardioverter defibrillator
lead extraction
pacemaker
Journal
Journal of cardiovascular electrophysiology
ISSN: 1540-8167
Titre abrégé: J Cardiovasc Electrophysiol
Pays: United States
ID NLM: 9010756
Informations de publication
Date de publication:
03 2020
03 2020
Historique:
received:
12
08
2019
revised:
22
12
2019
accepted:
29
12
2019
pubmed:
17
1
2020
medline:
16
12
2020
entrez:
17
1
2020
Statut:
ppublish
Résumé
Cardiac implantable electronic devices (CIEDs) frequently need to be extracted due to infection, hardware failure, and other causes. The extraction of the CIED is typically performed using percutaneous methods. While these procedures are mostly performed without incident there is a small risk of significant complications. Dedicated imaging pre-CEID removal to include the central veins and heart with multidetector computed tomography (MDCT) can be utilized to evaluate the lead course and termination, the integrity of the central veins and cardiac chambers, and identify potential complications that may alter the lead extraction procedure as well as reimplantation of subsequent leads. Indications for preprocedural imaging, the technique of dedicated preprocedural lead extraction MDCT, and the approach to the interpretation of the images is discussed in this review.
Types de publication
Journal Article
Review
Langues
eng
Sous-ensembles de citation
IM
Pagination
723-732Informations de copyright
© 2020 Wiley Periodicals, Inc.
Références
Rickard J, Wilkoff BL. Extraction of implantable cardiac electronic devices. Curr Cardiol Rep. 2011;13:407-414.
Rusanov A, Spotnitz HM. A 15-year experience with permanent pacemaker and defibrillator lead and patch extractions. Ann Thorac Surg. 2010;89:44-50.
Kratz JM, Toole JM. Pacemaker and internal cardioverter defibrillator lead extraction: a safe and effective surgical approach. Ann Thorac Surg. 2010;90:1411-1417.
Grammes JA, Schulze CM, Al-Bataineh M, et al. Percutaneous pacemaker and implantable cardioverter-defibrillator lead extraction in 100 patients with intracardiac vegetations defined by transesophageal echocardiogram. J Am Coll Cardiol. 2010;55:886-894.
Meyer LT, Boll DT. Novel technique for addressing streak artifact in gated dual-source MDCT angiography utilizing ECG-editing. Eur Radiol. 2008;18:2446-2448.
Lewis RK, Pokorney SD, Greenfield RA, et al. Preprocedural ECG-gated computed tomography for prevention of complications during lead extraction. Pacing Clin Electrophysiol. 2014;37(10):1297-1305.
Banaszewski M, Stepinksa J. Right heart perforation by pacemaker leads. Arch Med Sci. 2012;8(1):11-13.
Kirsch J, Araoz PA, Steinberg FB, Feltcher JG, McCollough CH, Williamson EE. Prevalence and significance of incidental extracardiac findings at 64-multidetector coronary CTA. J Thorac Imaging. 2007;22(4):330-334.