Study on the Flexural Performance of Hybrid-Reinforced Concrete Beams with a New Cathodic Protection System Subjected to Corrosion.

CFRP SFCB flexural performance hybrid-reinforced concrete beam impressed current cathodic protection

Journal

Materials (Basel, Switzerland)
ISSN: 1996-1944
Titre abrégé: Materials (Basel)
Pays: Switzerland
ID NLM: 101555929

Informations de publication

Date de publication:
05 Jan 2020
Historique:
received: 29 11 2019
revised: 26 12 2019
accepted: 03 01 2020
entrez: 18 1 2020
pubmed: 18 1 2020
medline: 18 1 2020
Statut: epublish

Résumé

Steel corrosion is considered as the main factor for the insufficient durability of concrete structures, especially in the marine environment. In this paper, to further inhibit steel corrosion in a high chloride environment and take advantage of the dual-functional carbon fiber reinforced polymer (CFRP), the impressed current cathodic protection (ICCP) technique was applied to the hybrid-reinforced concrete beam with internally embedded CFRP bars and steel fiber reinforced polymer composite bar (SFCB) as the anode material while the steel bar was compelled to the cathode. The effect of the new ICCP system on the flexural performance of the hybrid-reinforced concrete beam subjected to corrosion was verified experimentally. First, the electricity-accelerated precorrosion test was performed for the steel bar in the hybrid-reinforced beams with a target corrosion ratio of 5%. Then, the dry-wet cycles corrosion was conducted and the ICCP system was activated simultaneously for the hybrid-reinforced concrete beam for 180 days. Finally, the three-point bending experiment was carried out for the hybrid-reinforced concrete beams. The steel bars were taken out from the concrete to quantitatively measure the corrosion ratio after flexural tests. Results showed that the further corrosion of steel bars could be inhibited effectively by the ICCP treatment with the CFRP bar and the SFCB as the anode. Additionally, the ICCP system showed an obvious effect on the flexural behavior of the hybrid-reinforced concrete beams: The crack load and ultimate load, as well as the stiffness, were enhanced notably compared with the beam without ICCP treatment. Compared with the SFCB anode, the ICCP system with the CFRP bar as the anode material was more effective for the hybrid-reinforced concrete beam to prevent the steel corrosion.

Identifiants

pubmed: 31948090
pii: ma13010234
doi: 10.3390/ma13010234
pmc: PMC6982293
pii:
doi:

Types de publication

Journal Article

Langues

eng

Subventions

Organisme : National Natural Science Foundation of China
ID : 51622808, 51778371, 51908372
Organisme : Shenzhen Basic Research Project
ID : GJHZ20170314105503899

Références

Materials (Basel). 2018 May 07;11(5):null
pubmed: 29735911
Materials (Basel). 2019 Jan 02;12(1):null
pubmed: 30609741

Auteurs

Yingwu Zhou (Y)

Guangdong Provincial Key Laboratory of Durability for Marine Civil Engineering, Shenzhen University, Shenzhen 518060, China.

Yaowei Zheng (Y)

Guangdong Provincial Key Laboratory of Durability for Marine Civil Engineering, Shenzhen University, Shenzhen 518060, China.

Lili Sui (L)

Guangdong Provincial Key Laboratory of Durability for Marine Civil Engineering, Shenzhen University, Shenzhen 518060, China.

Biao Hu (B)

Guangdong Provincial Key Laboratory of Durability for Marine Civil Engineering, Shenzhen University, Shenzhen 518060, China.

Xiaoxu Huang (X)

Guangdong Provincial Key Laboratory of Durability for Marine Civil Engineering, Shenzhen University, Shenzhen 518060, China.

Classifications MeSH