The Changes of Endotracheal Tube Cuff Pressure during Manual and Intermittent Controlling in Intensive Care Units.
Cuff pressure
intratracheal
intubation
trachea
Journal
Iranian journal of nursing and midwifery research
ISSN: 1735-9066
Titre abrégé: Iran J Nurs Midwifery Res
Pays: India
ID NLM: 101558775
Informations de publication
Date de publication:
Historique:
received:
03
03
2019
revised:
02
11
2019
accepted:
11
11
2019
entrez:
21
1
2020
pubmed:
21
1
2020
medline:
21
1
2020
Statut:
epublish
Résumé
Usually, the endotracheal tube cuff pressure is controlled by cuff pressure monitoring. However, the intermittent pilot-manometer connection and disconnection may cause a change in the adjusted pressure. This study aimed to investigate changes in the endotracheal tube cuff pressure using both manual and intermittent controls. A semi-experimental within-subject design was conducted. Fifty-nine intubated patients in the Mazandaran Intensive Care Units (ICUs) participated through convenience sampling in 2018. In the control condition, first, the cuff pressure was adjusted in 25 cm H The mean and Standard Deviation (SD) change of cuff pressure after 1 minute, from 25 cm H The tracheal tube cuff pressure has been significantly reduced during manual intermittent measuring. Therefore, it is suggested that continuous cuff pressure monitoring and regulation should be used.
Sections du résumé
BACKGROUND
BACKGROUND
Usually, the endotracheal tube cuff pressure is controlled by cuff pressure monitoring. However, the intermittent pilot-manometer connection and disconnection may cause a change in the adjusted pressure. This study aimed to investigate changes in the endotracheal tube cuff pressure using both manual and intermittent controls.
MATERIALS AND METHODS
METHODS
A semi-experimental within-subject design was conducted. Fifty-nine intubated patients in the Mazandaran Intensive Care Units (ICUs) participated through convenience sampling in 2018. In the control condition, first, the cuff pressure was adjusted in 25 cm H
RESULTS
RESULTS
The mean and Standard Deviation (SD) change of cuff pressure after 1 minute, from 25 cm H
CONCLUSIONS
CONCLUSIONS
The tracheal tube cuff pressure has been significantly reduced during manual intermittent measuring. Therefore, it is suggested that continuous cuff pressure monitoring and regulation should be used.
Identifiants
pubmed: 31956601
doi: 10.4103/ijnmr.IJNMR_55_19
pii: IJNMR-25-71
pmc: PMC6952914
doi:
Types de publication
Journal Article
Langues
eng
Pagination
71-75Informations de copyright
Copyright: © 2019 Iranian Journal of Nursing and Midwifery Research.
Déclaration de conflit d'intérêts
Nothing to declare.
Références
Rev Bras Anestesiol. 2016 Mar-Apr;66(2):120-5
pubmed: 25530273
Nurs Crit Care. 2019 Mar;24(2):76-82
pubmed: 30537009
Anesthesiol Res Pract. 2017;2017:2032748
pubmed: 29463980
Crit Care. 2014 Apr 21;18(2):R77
pubmed: 24751286
Crit Care. 2007;11(5):R109
pubmed: 17915017
Respir Care. 2018 May;63(5):495-501
pubmed: 29382793
Acta Anaesthesiol Scand. 2019 Feb;63(2):277
pubmed: 30328095
Eur Respir J. 2002 Oct;20(4):1010-3
pubmed: 12412697
AACN Adv Crit Care. 2008 Apr-Jun;19(2):235-43
pubmed: 18560292
Eur J Anaesthesiol. 2014 Mar;31(3):166-71
pubmed: 24270899
Crit Care Med. 2007 Jun;35(6):1543-9
pubmed: 17452937
Rev Bras Enferm. 2017 Nov-Dec;70(6):1145-1150
pubmed: 29160473
Acta Anaesthesiol Scand. 2019 Jan;63(1):55-60
pubmed: 30132783
BMC Anesthesiol. 2017 Sep 19;17(1):129
pubmed: 28927375
Am J Crit Care. 2009 Mar;18(2):133-43
pubmed: 19255103
Trials. 2018 Apr 4;19(1):217
pubmed: 29615093
Anesthesiology. 2010 Mar;112(3):652-7
pubmed: 20179502
Anesth Pain Med. 2017 Jul 22;7(4):e57801
pubmed: 29430408
Curr Opin Crit Care. 2013 Oct;19(5):440-7
pubmed: 23856895
Eur J Anaesthesiol. 2009 Mar;26(3):229-34
pubmed: 19244697
Respir Care. 2014 Jun;59(6):933-52; discussion 952-5
pubmed: 24891200
J Perioper Pract. 2011 Nov;21(11):379-86
pubmed: 22165491
Am J Crit Care. 2011 Mar;20(2):109-17; quiz 118
pubmed: 21362715
Am J Respir Crit Care Med. 2011 Nov 1;184(9):1041-7
pubmed: 21836137