Consumption Optimization in an Office Building Considering Flexible Loads and User Comfort.
SCADA
building energy management
demand response
load shifting
user comfort
Journal
Sensors (Basel, Switzerland)
ISSN: 1424-8220
Titre abrégé: Sensors (Basel)
Pays: Switzerland
ID NLM: 101204366
Informations de publication
Date de publication:
21 Jan 2020
21 Jan 2020
Historique:
received:
05
11
2019
revised:
16
01
2020
accepted:
17
01
2020
entrez:
25
1
2020
pubmed:
25
1
2020
medline:
25
1
2020
Statut:
epublish
Résumé
This paper presents a multiperiod optimization algorithm that is implemented in a Supervisory Control and Data Acquisition system. The algorithm controls lights and air conditioners as flexible loads to reduce the consumption and controls a dishwasher as a deferrable load to implement the load shifting. Several parameters are considered to implement the algorithm for several successive periods in a real building operation. In the proposed methodology, optimization is done regarding user comfort, which is modeled in the objective function related to the indoor temperature in each room, and in the constraints in order to prevent excessive power reduction, according to users' preferences. Additionally, the operation cycle of a dishwasher is included, and the algorithm selects the best starting point based on the appliance weights and power availability in each period. With the proposed methodology, the building energy manager can specify the moments when the optimization is run with consideration of the operational constraints. Accordingly, the main contribution of the paper is to provide and integrate a methodology to minimize the difference between the actual and the desired temperature in each room, as a measure of comfort, respecting constraints that can be easily bounded by building users and manager. The case study considers the real consumption data of an office building which contains 20 lights, 10 ACs, and one dishwasher. Three scenarios have been designed to focus on different functionalities. The outcomes of the paper include proof of the performance of the optimization algorithm and how such a system can effectively minimize electricity consumption by implementing demand response programs and using them in smart grid contexts.
Identifiants
pubmed: 31973147
pii: s20030593
doi: 10.3390/s20030593
pmc: PMC7037999
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Subventions
Organisme : Programa Operacional Temático Factores de Competitividade
ID : COLORS
Organisme : European Commission
ID : DOMINOES
Organisme : Fundação para a Ciência e a Tecnologia
ID : 760
Déclaration de conflit d'intérêts
The authors declare no conflict of interest.