Accuracy of noncycloplegic photorefraction using Spot photoscreener in detecting amblyopia risk factors in preschool children in an Indian eye clinic.
Amblyopia
/ diagnosis
Child, Preschool
Cross-Sectional Studies
Equipment Design
Female
Humans
India
/ epidemiology
Infant
Male
Prevalence
Referral and Consultation
Refraction, Ocular
/ physiology
Reproducibility of Results
Retrospective Studies
Risk Assessment
/ methods
Risk Factors
Vision Screening
/ instrumentation
Amblyopia
cyclorefraction
photoscreener
Journal
Indian journal of ophthalmology
ISSN: 1998-3689
Titre abrégé: Indian J Ophthalmol
Pays: India
ID NLM: 0405376
Informations de publication
Date de publication:
03 2020
03 2020
Historique:
entrez:
15
2
2020
pubmed:
15
2
2020
medline:
26
2
2021
Statut:
ppublish
Résumé
To evaluate the accuracy of Spot photoscreener (PS) as a noncycloplegic photorefractor in detecting amblyopia risk factors (ARFs) in preschool children in an Indian eye clinic setting. Also, to derive appropriate cutoff values for screening to obtain maximum sensitivity and specificity of the device in detecting ARF. This was a cross-sectional study conducted in the outpatient pediatric eye clinic at a tertiary eye care institute. A Spot PS was used to screen all the children between the ages of 6 months and 5 years that presented to the eye clinic from August 2018 to October 2018. This screening was followed by a complete eye examination, including cycloplegic refraction by a masked examiner. The 2013 American Association for Pediatric Ophthalmology and Strabismus (AAPOS) guidelines were considered the standard cutoff values for clinically significant refractive error in children younger than 5 years of age. The study comprised of 219 children. The Spot PS diagnosed 135 (61.64%) children with ARF as compared with 124 (56.62%) children detected by clinic examination. For ARF detection, the Spot photoscreeneer had 85.48% sensitivity, 69.47% specificity, 78.52% positive predictive value and 78.57% negative predictive value. The sensitivity for detection of strabismus and hypermetropia was very low (42% and 36%, respectively). The 95% limits of agreement ranged from -5.48 to +5.59 diopters (D) with a bias of 0.06 D for spherical equivalent between noncycloplegic photorefraction and cycloplegic refraction. The Spot PS may be used as a screening tool to detect ARF in children younger than 5 years of age keeping its limitations in consideration. However, the performance can be improved by modifying the cutoff values for the referral.
Identifiants
pubmed: 32057013
pii: IndianJOphthalmol_2020_68_3_504_278370
doi: 10.4103/ijo.IJO_701_19
pmc: PMC7043179
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
504-509Déclaration de conflit d'intérêts
None
Références
BMJ. 2002 Jun 29;324(7353):1549
pubmed: 12089090
Transl Vis Sci Technol. 2018 Jun 4;7(3):12
pubmed: 29881649
Br J Ophthalmol. 2019 Apr;103(4):517-522
pubmed: 29986946
Graefes Arch Clin Exp Ophthalmol. 2005 Jul;243(7):637-45
pubmed: 15650858
J AAPOS. 2014 Oct;18(5):476-80
pubmed: 25266832
PLoS One. 2016 Feb 16;11(2):e0149561
pubmed: 26882106
Ophthalmology. 2008 Jul;115(7):1229-1236.e1
pubmed: 17953989
J AAPOS. 2013 Feb;17(1):4-8
pubmed: 23360915
Can J Ophthalmol. 2017 Oct;52(5):480-485
pubmed: 28985808
J AAPOS. 2014 Apr;18(2):169-72
pubmed: 24698615
Pediatrics. 2011 Feb;127(2):340-6
pubmed: 21282267
J AAPOS. 2015 Dec;19(6):512-4
pubmed: 26691029
Am J Ophthalmol. 2017 Jun;178:79-83
pubmed: 28336401
Ophthalmology. 2014 Mar;121(3):622-9.e1
pubmed: 24140117
Community Eye Health. 2000;13(33):3-5
pubmed: 17491943