Randomized Trial of 2 Endoscopic Radial Artery Harvesting Devices-Immunofluorescence Assessment.


Journal

The Annals of thoracic surgery
ISSN: 1552-6259
Titre abrégé: Ann Thorac Surg
Pays: Netherlands
ID NLM: 15030100R

Informations de publication

Date de publication:
09 2020
Historique:
received: 26 05 2019
revised: 15 09 2019
accepted: 23 12 2019
pubmed: 15 2 2020
medline: 3 11 2020
entrez: 15 2 2020
Statut: ppublish

Résumé

Various devices are available for endoscopic radial artery harvesting during coronary artery bypass grafting. Thermal spread and graft damage, however, are common concerns. The aim of this study was to compare the MiFusion TLS2 system (Endotrust, Nettetal Germany) with direct heat technique and the LigaSure Maryland system (Medtronic, Dublin, Ireland) using advanced bipolar technique in a prospective randomized study. One hundred consecutive patients undergoing coronary artery bypass grafting with endoscopic radial artery harvesting were prospectively included and randomized 1:1. The proximal (brachial) ends of the grafts were analyzed using fluorescence microscopy with focus on graft integrity. In addition, harvesting time, graft sealing, residual bleeding, and incidence of neurological disorders were compared. Patient age was 67 ± 8 years. Mean harvesting time was 26.5 ± 9 minutes for the TLS2 and 23.2 ± 8 minutes for the LigaSure (P = .049). Overall graft integrity was good in both groups. A significantly better graft integrity was observed in the LigaSure group (scale 0 to 3; 3 = best) with 2.5 ± 0.6 for TLS2 and 2.8 ± 0.4 for LigaSure (P = .031). LigaSure provided significantly better graft sealing (scale 0 to 2; 0 = best) with 0.6 ± 0.7 vs 1.0 ± 0.6 (TLS2) (P = .006) and less residual bleeding (scale 1 to 5; 1 = best) with 1.4 ± 0.6 vs 2.0 ± 0.9 (TLS2) (P < .001). Transient sensibility disorders were less frequently observed with LigaSure (2% vs 16%, P = .015). Endoscopic radial artery harvesting can be performed with excellent results and good graft integrity using both devices. Compared with the MiFusion TLS2, the LigaSure device led to faster procedural times and resulted in better graft integrity. Along with providing a better seal, LigaSure was associated with less sensibility disorders.

Sections du résumé

BACKGROUND
Various devices are available for endoscopic radial artery harvesting during coronary artery bypass grafting. Thermal spread and graft damage, however, are common concerns. The aim of this study was to compare the MiFusion TLS2 system (Endotrust, Nettetal Germany) with direct heat technique and the LigaSure Maryland system (Medtronic, Dublin, Ireland) using advanced bipolar technique in a prospective randomized study.
METHODS
One hundred consecutive patients undergoing coronary artery bypass grafting with endoscopic radial artery harvesting were prospectively included and randomized 1:1. The proximal (brachial) ends of the grafts were analyzed using fluorescence microscopy with focus on graft integrity. In addition, harvesting time, graft sealing, residual bleeding, and incidence of neurological disorders were compared.
RESULTS
Patient age was 67 ± 8 years. Mean harvesting time was 26.5 ± 9 minutes for the TLS2 and 23.2 ± 8 minutes for the LigaSure (P = .049). Overall graft integrity was good in both groups. A significantly better graft integrity was observed in the LigaSure group (scale 0 to 3; 3 = best) with 2.5 ± 0.6 for TLS2 and 2.8 ± 0.4 for LigaSure (P = .031). LigaSure provided significantly better graft sealing (scale 0 to 2; 0 = best) with 0.6 ± 0.7 vs 1.0 ± 0.6 (TLS2) (P = .006) and less residual bleeding (scale 1 to 5; 1 = best) with 1.4 ± 0.6 vs 2.0 ± 0.9 (TLS2) (P < .001). Transient sensibility disorders were less frequently observed with LigaSure (2% vs 16%, P = .015).
CONCLUSIONS
Endoscopic radial artery harvesting can be performed with excellent results and good graft integrity using both devices. Compared with the MiFusion TLS2, the LigaSure device led to faster procedural times and resulted in better graft integrity. Along with providing a better seal, LigaSure was associated with less sensibility disorders.

Identifiants

pubmed: 32057811
pii: S0003-4975(20)30182-X
doi: 10.1016/j.athoracsur.2019.12.063
pii:
doi:

Types de publication

Journal Article Randomized Controlled Trial

Langues

eng

Sous-ensembles de citation

IM

Pagination

897-902

Informations de copyright

Copyright © 2020 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Auteurs

Arnaud Van Linden (A)

Department of Cardiothoracic and Vascular Surgery, Goethe University Hospital Frankfurt, Frankfurt. Electronic address: arnaud.vanlinden@kgu.de.

Florian Hecker (F)

Department of Cardiothoracic and Vascular Surgery, Goethe University Hospital Frankfurt, Frankfurt.

Jasper Lehmann-Grube (J)

Medical School, Justus Liebig University Giessen, Giessen.

Mani Arsalan (M)

Department of Cardiothoracic and Vascular Surgery, Goethe University Hospital Frankfurt, Frankfurt.

Manfred Richter (M)

Department of Cardiac Surgery, Kerckhoff Clinic, Bad Nauheim, Germany.

Brigitte Matzke (B)

Max-Planck-Institute for Heart and Lung Research, Bad Nauheim, Germany.

Tomas Holubec (T)

Department of Cardiothoracic and Vascular Surgery, Goethe University Hospital Frankfurt, Frankfurt.

Thomas Walther (T)

Department of Cardiothoracic and Vascular Surgery, Goethe University Hospital Frankfurt, Frankfurt.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH