Ballistic research techniques: visualizing gunshot wounding patterns.
CT
Gunshot
Limb
Ultrasound
Wound
X-ray
Journal
International journal of legal medicine
ISSN: 1437-1596
Titre abrégé: Int J Legal Med
Pays: Germany
ID NLM: 9101456
Informations de publication
Date de publication:
May 2020
May 2020
Historique:
received:
28
11
2019
accepted:
31
01
2020
pubmed:
16
2
2020
medline:
4
2
2021
entrez:
16
2
2020
Statut:
ppublish
Résumé
There are difficulties associated with mapping gunshot wound (GSW) patterns within opaque models. Depending on the damage measurement parameters required, there are multiple techniques that can provide methods of "seeing" the GSW pattern within an opaque model. The aim of this paper was to test several of these techniques within a cadaveric animal limb model to determine the most effective. The techniques of interest were flash X-ray, ultrasound, physical dissection, and computed-tomography (CT). Fallow deer hind limbs were chosen for the model with four limbs used for each technique tested. Quarantined 7.62 × 39 mm ammunition was used for each shot, and each limb was only shot once, on an outdoor range with shots impacting at muzzle velocity. Flash X-ray provided evidence of yaw within the limb during the projectile's flight; ultrasound though able to visualise the GSW track, was too subjective and was abandoned; dissection proved too unreliable due to the tissue being cadaveric so also too subjective; and lastly, CT with contrast provided excellent imaging in multiple viewing planes and 3D image reconstruction; this allowed versatile measurement of the GSW pattern to collect dimensions of damage as required. Of the different techniques examined in this study, CT with contrast proved the most effective to allow precise GSW pattern analysis within a cadaveric animal limb model. These findings may be beneficial to others wishing to undertake further ballistic study both within clinical and forensic fields.
Identifiants
pubmed: 32060625
doi: 10.1007/s00414-020-02265-5
pii: 10.1007/s00414-020-02265-5
pmc: PMC7181419
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1103-1114Références
Krauss M, Miller J (1960) Studies in wound ballistics temporary cavities and permanent tracts produced by high-velocity projectiles in gel. Technical Report No. CWLR 2340. Army Chemical Centre, Maryland. Reproduced by Armed Services Technical Information Agency, Arlington, Virginia
Fackler ML, Malinowski JA (1985) The wound profile: a visual method for quantifying gunshot wound components. J Trauma 25(6):522–529
doi: 10.1097/00005373-198506000-00009
Knudsen PJT, Vigsnæs JS, Rasmussen R, Nissen PS (1995) Terminal ballistics of 7.62 mm NATO bullets: experiments in ordnance gelatin. Int J Legal Med 108:62–67. https://doi.org/10.1007/BF01369906
doi: 10.1007/BF01369906
pubmed: 8547160
Jussila J (2005) Measurement of kinetic energy dissipation with gelatine fissure formation with special reference to gelatine validation. Forensic Sci Int 150(1):53–62. https://doi.org/10.1016/j.forsciint.2004.06.038
doi: 10.1016/j.forsciint.2004.06.038
pubmed: 15837008
Kneubuehl BP, Coupland RM, Rothschild MA, Thali MJ (2011) Wound ballistics: basics and applications, 3rd edn. Springer, Berlin
Kieser DC, Carr DJ, Leclair SCJ, Horsfall I, Theis J-C, Swain MV, Kieser JA (2013) Clothing increases the risk of indirect ballistic fractures. J Orthop Surg Res 8(42):1–6
Swain MV, Kieser DC, Shah S, Kieser JA (2014) Projectile penetration into ballistic gelatin. J Mech Behav Biomed Mater 29:385–392. https://doi.org/10.1016/j.jmbbm.2013.09.024
doi: 10.1016/j.jmbbm.2013.09.024
pubmed: 24184862
Mabbott A (2015) The overmatching of UK police body armour. PhD Thesis. Cranfield University, Defence Academy of the United Kingdom
Susu L, Cheng X, Yaoke W, Xiaoyun Z (2016) A new motion model of rifle bullet penetration into ballistic gelatin. Int J Impact Eng 93:1–10. https://doi.org/10.1016/j.ijimpeng.2016.02.003
doi: 10.1016/j.ijimpeng.2016.02.003
Mahoney PF, Carr DJ, Miller D, Teagle M (2017) The effect of helmet materials and simulated bone and tissue layers on bullet behaviour in a gelatine model of overmatch penetrating head injury. Int J Legal Med 131(6):1765–1776. https://doi.org/10.1007/s00414-017-1665-8
doi: 10.1007/s00414-017-1665-8
pubmed: 28815306
pmcid: 5635073
Carr DJ, Stevenson T, Mahoney P (2018) The use of gelatine in wound ballistics research. Int J Legal Med 132(6):1659–1664. https://doi.org/10.1007/s00414-0181831-7
doi: 10.1007/s00414-0181831-7
pubmed: 29696465
pmcid: 6208714
Stevenson T, Carr DJ, Stapley SA (2019) The effect of military clothing on gunshot wounds in gelatine. Int J Legal Med 133(4):1121–1131. https://doi.org/10.1007/s00414-018-1972-8
doi: 10.1007/s00414-018-1972-8
pubmed: 30488352
Humphrey C, Kumaratilake J (2016) Ballistics and anatomical modelling - a review. Legal Med 23:21–29. https://doi.org/10.1016/j.legalmed.2016.09.002
doi: 10.1016/j.legalmed.2016.09.002
pubmed: 27890098
Mabbott A, Carr DJ, Champion S, Malbon C (2016) Comparison of porcine thorax to gelatine blocks for wound ballistics studies. Int J Legal Med 130(5):1353–1362. https://doi.org/10.1007/s00414-015-1309-9
doi: 10.1007/s00414-015-1309-9
pubmed: 26846765
pmcid: 4976058
Krauss M, Miller J (1956) Comparison of permanent and temporary cavities produced by high velocity rifle bullets in soft tissue. Report No. 2144. Chemical Warfare Laboratories, Army Chemical Centre, Maryland
Amato JJ, Rich NM (1971) Temporary cavity effects in blood vessel injury by high velocity missiles. J Cardiovasc Surg 11:146–155
Amato JJ, Billy LJ, Gruber RP, Rich NM (1974) Temporary cavitation in high-velocity pulmonary missile injury. Ann Thorac Surg 18(6):565–570. https://doi.org/10.1016/s0003-4975(10)64402-5
doi: 10.1016/s0003-4975(10)64402-5
pubmed: 4433177
Amato JJ, Billy LJ, Lawson NS, Rich NM (1974) High velocity missile injury: an experimental study of the retentive forces of tissue. Am J Surg 127:454–459
doi: 10.1016/0002-9610(74)90296-7
Boyer CN, Holland GE, Seely JF (2005) Flash X-ray observations of cavitation in cadaver thighs caused by high-velocity bullets. J Trauma 59(6):1463–1468. https://doi.org/10.1097/01.ta.0000195526.27014.c5
doi: 10.1097/01.ta.0000195526.27014.c5
pubmed: 16394923
Jin Y, Mai R, Wu C, Han R, Li B (2018) Comparison of ballistic impact effects between biological tissue and gelatin. J Mech Behav Biomed Mater 78:292–297. https://doi.org/10.1016/j.jmbbm.2017.11.033
doi: 10.1016/j.jmbbm.2017.11.033
pubmed: 29195221
Tayal VS, Beatty MA, Marx JA, Tomaszewski CA, Thomason MH (2004) FAST (focused assessment with sonography in trauma) accurate for cardiac and intraperitoneal injury in penetrating anterior chest trauma. J Ultrasound Med 23(4):467–472
doi: 10.7863/jum.2004.23.4.467
Burns B (2012) Bedside emergency department ultrasound in assessment of a gunshot wound. Australas J Ultrasound Med 15(1):24–25. https://doi.org/10.1002/j.2205-0140.2012.tb00138.x
doi: 10.1002/j.2205-0140.2012.tb00138.x
pubmed: 28191135
pmcid: 5025129
Li Q, Deng D, Tao J, Wu X, Yi F, Wang G, Yang F (2015) Ultrasonic imaging of gunshot wounds in pig limb. Genet Mol Res 14(2):4291–4302. https://doi.org/10.4238/2015.April.30.1
doi: 10.4238/2015.April.30.1
pubmed: 25966201
Morrow DS, Cupp JA, Broder JS (2016) Versatile, reusable, and inexpensive ultrasound phantom procedural trainers. J Ultrasound Med 35(4):831–841. https://doi.org/10.7863/ultra.15.04085
doi: 10.7863/ultra.15.04085
pubmed: 26969595
Olivieri P, Doctor M, Siadecki S, Rose G, Drake A, Saul T (2016) Sonographer preference for Knox versus ballistic gelatin for the creation of deep venous thrombosis ultrasound phantoms. Med Ultrason 18(4):531–532. https://doi.org/10.11152/mu-888
doi: 10.11152/mu-888
pubmed: 27981294
Doctor M, Katz A, McNamara SO, Leifer JH, Bambrick-Santoyo G, Saul T, Rose KM (2018) A novel method for creating custom shaped ballistic gelatin trainers using plaster molds. J Ultrasound 21(1):61–64. https://doi.org/10.1007/s40477-017-0274-1
doi: 10.1007/s40477-017-0274-1
pubmed: 29374397
Shah A (2018) A low-cost, reusable, ballistic gelatin ultrasound phantom for simulation of glenohumeral intraarticular injections. AEM Educ Train 2(2):169–173. https://doi.org/10.1002/aet2.10081
doi: 10.1002/aet2.10081
pubmed: 30051084
pmcid: 5996821
Özdemir M, Özdemir G, Eroğul O (2019) Investigating ballistic gelatin based phantom properties for ultrasound training. In: Lhotska L, Sukupova L, Lacković I, Ibbott G (eds) World Congress on Medical Physics and Biomedical Engineering, IFMBE Proceedings, Singapore, Vol 68, Issue 1. Springer Nature, Singapore
Fackler ML (1987) Wounds and injuries of the soft tissues. Institute Report No. 232. Letterman Army Institute of Research, San Francisco, California
Fackler ML (1988) Wound ballistics: a review of common misconceptions. JAMA 259(18):2730–2736
doi: 10.1001/jama.1988.03720180056033
Coupland R (1989) Technical aspects of war wound excision. Br J Surg 76:663–667
doi: 10.1002/bjs.1800760704
Fackler ML, Breteau JP, Courbil LJ, Taxit R, Glas J, Fievet JP (1989) Open wound drainage versus wound excision in treating the modern assault rifle wound. Surgery 105(5):576–584
pubmed: 2650003
Bellamy R, Zajtchuk R (1991) The evolution of wound ballistics: a brief history. In: Bellamy R, Zajtchuk R (Eds) Conventional warfare. Ballistics, Blasts and Burn Injuries. Office of the Surgeon General at TMM Publications, Walter Reed Army Medical Centre, Washington DC, pp 83–105
Bowyer GW, Rossiter ND (1997) Management of gunshot wounds of the limbs. J Bone Joint Surg (Br) 79(6):1031–1036
doi: 10.1302/0301-620X.79B6.0791031
MacFarlane C (2002) Aide memoire for the management of gunshot wounds. Ann R Coll Surg Engl 84:230–233
doi: 10.1308/003588402320439649
Penn-Barwell JG, Fries CA, Rickard RF (2017) Ballistic wound management and infection prevention. In: Breeze J, Penn-Barwell JG, Keene D, O’Reilly D, Jeyanathan J, Mahoney PF (eds) Ballistic trauma: a practical guide, 4th edn. Springer Publishing Ltd, pp 337–346
Berlin R, Gelin LE, Janzon B, Lewis DH, Rybeck B, Sandegård J, Seeman T (1976) Local effects of assault rifle bullets in live tissue. Part I. Acta Chir Scand Suppl 459:5–84
Albreht M, Sćepanović D, Ceramilac A, Milivojević V, Berger S, Tasić G, Tatić V, Todorić M, Popović D, Nanusević N (1979) Experimental soft tissue wounds caused by standard military rifles. Acta Chir Scand Suppl 489:185–198
pubmed: 291254
Tikka S, Cederberg A, Levanen J, Lotjonen V, Rokkanen P (1982) Local effects of three standard assault rifle projectiles in live tissue. Acta Chir Scand Suppl 508:61–77
pubmed: 6952705
Janzon B, Seeman T (1985) Muscle devitalization in high-energy missile wounds, and its dependence on energy transfer. J Trauma 25(2):138–144
doi: 10.1097/00005373-198502000-00009
Hopkinson DAW, Watts JC (1963) Studies in experimental missile injuries of skeletal muscle. Proc R Soc Med 56(June):461–468
pubmed: 13961685
pmcid: 1897040
Krauss M (1957) Studies in wound ballistics: temporary cavity effects in soft tissues. Mil Med 121(4):221–231
doi: 10.1093/milmed/121.4.221
Ziervogel JF (1979) A study of the muscle damage caused by the 7.62 NATO rifle. Acta Chir Scand Suppl 489:131–135
pubmed: 91287
Hollerman JJ, Fackler ML, Coldwell DM, Ben-Menachem Y (1990) Gunshot wounds: 2. Radiology. Am J Roentgenol 155(4):691–702. https://doi.org/10.2214/ajr.155.4.2119096
doi: 10.2214/ajr.155.4.2119096
Thali MJ, Yen K, Vock P, Ozdoba C, Kneubuehl BP, Sonnenschein M, Dirnhofer R (2003) Image-guided virtual autopsy findings of gunshot victims performed with multi-slice computed tomography and magnetic resonance imaging and subsequent correlation between radiology and autopsy findings. Forensic Sci Int 138(1–3):8–16
doi: 10.1016/S0379-0738(03)00225-1
Andenmatten MA, Thali MJ, Kneubuehl BP, Oesterhelweg L, Ross S, Spendlove D, Bolliger SA (2008) Gunshot injuries detected by post-mortem multislice computed tomography (MSCT): a feasibility study. Legal Med 10(6):287–292. https://doi.org/10.1016/j.legalmed.2008.03.005
doi: 10.1016/j.legalmed.2008.03.005
pubmed: 18485787
Usui A, Kawasumi Y, Hosokai Y, Kozakai M, Saito H, Funayama M (2016) Usefulness and limitations of postmortem computed tomography in forensic analysis of gunshot injuries: three case reports. Legal Med 18:98–103. https://doi.org/10.1016/j.legalmed.2016.01.004
doi: 10.1016/j.legalmed.2016.01.004
pubmed: 26832386
Stevenson T (2019) Ballistic extremity wounding: Quantifying tissue damage associated with military firearms. PhD Thesis. Cranfield University, Defence Academy of the United Kingdom
Stevenson T, Carr DJ, Gibb IE, Stapley SA (2019) The effect of military clothing on gunshot wound patterns in a cadaveric animal limb model. Int J Legal Med 133(6):1825–1833. https://doi.org/10.1007/s00414-019-02135-9
doi: 10.1007/s00414-019-02135-9
pubmed: 31414201
pmcid: 6811381
Kieser DC, Kanade S, Waddell NJ, Kieser JA, Theis JC, Swain MV (2014) The deer femur - a morphological and biomechanical animal model of the human femur. Biomed Mater Eng 24:1693–1703
pubmed: 24948453
Breeze J, Carr DJ, Mabbott A, Beckett S, Clasper JC (2015) Refrigeration and freezing of porcine tissue does not affect the retardation of fragment simulating projectiles. J Forensic Legal Med 32:77–83. https://doi.org/10.1016/j.jflm.2015.03.003
doi: 10.1016/j.jflm.2015.03.003
Penn-Barwell JG, Sargeant ID, Severe Lower Extremity Combat Trauma Study G (2016) Gun-shot injuries in UK military casualties - features associated with wound severity. Injury 47(5):1067–1071. https://doi.org/10.1016/j.injury.2016.02.004
doi: 10.1016/j.injury.2016.02.004
pubmed: 26948689
Schroeder M, King B (2012) Surveying the battlefield: illicit arms in Afghanistan, Iraq and Somalia. In: McDonald G, LeBrun E, Berman EG, Krause K (eds) Small arms survey 2012. Cambridge University Press, New York, pp 313–355