2D directional ramp filter.
Journal
Physics in medicine and biology
ISSN: 1361-6560
Titre abrégé: Phys Med Biol
Pays: England
ID NLM: 0401220
Informations de publication
Date de publication:
14 04 2020
14 04 2020
Historique:
pubmed:
23
2
2020
medline:
2
10
2020
entrez:
21
2
2020
Statut:
epublish
Résumé
Usual tomographic reconstruction methods start by filtering projections before backprojecting the data. In some cases, inverting the filtering and the backprojection steps can be useful to preserve spatial information. In this paper, an intermediate between a filter-backproject and a backproject-filter approach is proposed, based on the extension of the usual ramp filter to two dimensions. To this end, an expression for a band-limited 2D version of the ramp filter is derived. We have tested this filter on simulated x-ray CT projections of a Shepp-Logan phantom and on proton CT list-mode data. We accurately reconstructed the x-ray CT and the proton CT data, although the reconstruction can be slightly noisier than a standard filtered backprojection in some cases. A slight improvement of the spatial resolution of proton CT images reconstructed with this 2D filter has been observed.
Identifiants
pubmed: 32079009
doi: 10.1088/1361-6560/ab7875
doi:
Substances chimiques
Protons
0
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM