Radiation dose reduction for CT-guided intrathecal nusinersen administration in adult patients with spinal muscular atrophy.
Journal
Scientific reports
ISSN: 2045-2322
Titre abrégé: Sci Rep
Pays: England
ID NLM: 101563288
Informations de publication
Date de publication:
25 02 2020
25 02 2020
Historique:
received:
14
11
2019
accepted:
24
01
2020
entrez:
27
2
2020
pubmed:
27
2
2020
medline:
11
11
2020
Statut:
epublish
Résumé
Intrathecal administration of nusinersen in adult spinal muscular atrophy (SMA) patients with scoliosis and spondylodesis requires image guidance, which is preferably achieved with multi-detector computed tomography (MDCT). As long-term treatment is necessary and patients are young, radiation doses should be reduced to a minimum whilst a sufficient image quality for precise interventional performance should be kept. We compared 44 MDCT standard-dose scans (133.0-200.0 mA) with a hybrid iterative reconstruction (iDose4) to 20 low-dose scans (20.0-67.0 mA) with iterative model reconstruction (IMR), which were performed for procedure planning of intrathecal nusinersen administration in 13 adult patients with SMA and complex spinal conditions. Qualitative image evaluation, including confidence for intervention planning, was performed by two neuroradiologists for standard- and low-dose scans. All 64 MDCT-guided intrathecal administrations of nusinersen were successful. The dose length product (DLP) was significantly lower when using low-dose scanning with IMR (median DLP of standard-dose scans: 92.0 mGy•cm vs. low-dose scans: 34.5 mGy•cm; p < 0.0001). Image quality was significantly reduced for low-dose compared to standard-dose scanning. However, bone/soft tissue contrast and confidence for intervention planning were not significantly impaired in low-dose MDCT according to both readers, showing good inter-reader agreement. Thus, we hereby demonstrate a low-dose MDCT protocol combined with advanced image reconstruction for scanning during procedure planning as a viable option for image guidance in intrathecal nusinersen treatment of adult SMA patients with complex spinal conditions.
Identifiants
pubmed: 32099042
doi: 10.1038/s41598-020-60240-x
pii: 10.1038/s41598-020-60240-x
pmc: PMC7042284
doi:
Substances chimiques
Oligonucleotides
0
nusinersen
5Z9SP3X666
Types de publication
Clinical Trial
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
3406Références
Lefebvre, S. et al. Identification and characterization of a spinal muscular atrophy-determining gene. Cell 80, 155–165 (1995).
doi: 10.1016/0092-8674(95)90460-3
Wurster, C. D. et al. Intrathecal administration of nusinersen in adolescent and adult SMA type 2 and 3 patients. Journal of neurology 266, 183–194 (2019).
doi: 10.1007/s00415-018-9124-0
Stolte, B. et al. Feasibility and safety of intrathecal treatment with nusinersen in adult patients with spinal muscular atrophy. Therapeutic advances in neurological disorders 11, 1756286418803246 (2018).
doi: 10.1177/1756286418803246
Brenner, D. J. & Hall, E. J. Computed tomography–an increasing source of radiation exposure. The New England journal of medicine 357, 2277–2284, https://doi.org/10.1056/NEJMra072149 (2007).
doi: 10.1056/NEJMra072149
pubmed: 18046031
Richards, P. J., George, J. & Diagnostic, C. T. radiation and cancer induction. Skeletal Radiol 39, 421–424, https://doi.org/10.1007/s00256-009-0819-2 (2010).
doi: 10.1007/s00256-009-0819-2
pubmed: 19953245
Oldenburg, D. et al. Radiation exposure of image-guided intrathecal administration of nusinersen to adult patients with spinal muscular atrophy. Neuroradiology, 1-10 (2019).
Cordts, I. et al. Intrathecal nusinersen administration in adult spinal muscular atrophy patients with complex spinal anatomy. Therapeutic advances in neurological disorders in press (2019).
Bevelacqua, J. J. Practical and effective ALARA. Health Phys. 98(Suppl 2), S39–47, https://doi.org/10.1097/HP.0b013e3181d18d63 (2010).
doi: 10.1097/HP.0b013e3181d18d63
pubmed: 20386191
Prasad, K. N., Cole, W. C. & Haase, G. M. Radiation protection in humans: extending the concept of as low as reasonably achievable (ALARA) from dose to biological damage. Br. J. Radiol. 77, 97–99, https://doi.org/10.1259/bjr/88081058 (2004).
doi: 10.1259/bjr/88081058
pubmed: 15010379
Willemink, M. J. et al. Iterative reconstruction techniques for computed tomography Part 1: technical principles. European radiology 23, 1623–1631, https://doi.org/10.1007/s00330-012-2765-y (2013).
doi: 10.1007/s00330-012-2765-y
pubmed: 23314600
Willemink, M. J. et al. Iterative reconstruction techniques for computed tomography part 2: initial results in dose reduction and image quality. European radiology 23, 1632–1642, https://doi.org/10.1007/s00330-012-2764-z (2013).
doi: 10.1007/s00330-012-2764-z
pubmed: 23322411
Willemink, M. J. & Noel, P. B. The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence. European radiology 29, 2185–2195, https://doi.org/10.1007/s00330-018-5810-7 (2019).
doi: 10.1007/s00330-018-5810-7
pubmed: 30377791
Cordts, I. et al. Intrathecal nusinersen administration in adult spinal muscular atrophy patients with complex spinal anatomy. Therapeutic advances in neurological disorders (2019).
Sollmann, N. et al. Systematic Evaluation of Low-dose MDCT for Planning Purposes of Lumbosacral Periradicular Infiltrations. Clin Neuroradiol, https://doi.org/10.1007/s00062-019-00844-7 (2019).
Kizina, K. et al. Clinical implication of dosimetry of computed tomography-and fluoroscopy-guided intrathecal therapy with nusinersen in adult patients with spinal muscular atrophy. Frontiers in Neurology 10 (2019).
Pearce, M. S. et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. The Lancet 380, 499–505 (2012).
doi: 10.1016/S0140-6736(12)60815-0
Marci, R. et al. Radiations and female fertility. Reproductive Biology and Endocrinology 16, 112 (2018).
doi: 10.1186/s12958-018-0432-0
Ahmad, G. & Agarwal, A. In Male Infertility 185–196 (Springer, 2017).
Veerapandiyan, A. et al. Cervical puncture to deliver nusinersen in patients with spinal muscular atrophy. Neurology 91, e620–e624 (2018).
doi: 10.1212/WNL.0000000000006006
Wurster, C. D. & Ludolph, A. C. Antisense oligonucleotides in neurological disorders. Therapeutic Advances in Neurological Disorders 11, 1756286418776932 (2018).
pubmed: 29854003
pmcid: 5971383
Kroll, H. et al. Trends in lumbar puncture over 2 decades: a dramatic shift to radiology. American Journal of Roentgenology 204, 15–19 (2015).
doi: 10.2214/AJR.14.12622
Hudgins, P., Fountain, A., Chapman, P. & Shah, L. Difficult lumbar puncture: Pitfalls and tips from the trenches. American Journal of Neuroradiology 38, 1276–1283 (2017).
doi: 10.3174/ajnr.A5128
Brook, A. D., Burns, J., Dauer, E., Schoendfeld, A. H. & Miller, T. S. Comparison of CT and fluoroscopic guidance for lumbar puncture in an obese population with prior failed unguided attempt. Journal of neurointerventional surgery 6, 323–327 (2014).
doi: 10.1136/neurintsurg-2013-010745
Debnam, J. M. et al. Multidetector CT-guided lumbar puncture in patients with cancer. Interventional Neuroradiology 15, 61–66 (2009).
doi: 10.1177/159101990901500109
Rogits, B. et al. Prospective Evaluation of the radiologist’s hand dose in CT-guided interventions. Rofo 185, 1081–1088, https://doi.org/10.1055/s-0033-1350368 (2013).
doi: 10.1055/s-0033-1350368
pubmed: 23897530
Dietrich, T. J. et al. Fluoroscopy-guided versus CT-guided Lumbar Steroid Injections: Comparison of Radiation Exposure and Outcomes. Radiology 290, 752–759, https://doi.org/10.1148/radiol.2018181224 (2019).
doi: 10.1148/radiol.2018181224
pubmed: 30620259
Mei, K. et al. Is multidetector CT-based bone mineral density and quantitative bone microstructure assessment at the spine still feasible using ultra-low tube current and sparse sampling? European radiology 27, 5261–5271, https://doi.org/10.1007/s00330-017-4904-y (2017).
doi: 10.1007/s00330-017-4904-y
pubmed: 28639046
pmcid: 5674130
Sollmann, N. et al. Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures. European radiology 29, 3606–3616, https://doi.org/10.1007/s00330-019-06090-2 (2019).
doi: 10.1007/s00330-019-06090-2
pubmed: 30903337
pmcid: 6554251
Chen, B. et al. In The Fifth International Conference on Image Formation in X-Ray Computed Tomography, Salt Lake City. 52–55.
Koesters, T., Knoll, F., Sodickson, A., Sodickson, D. K. & Otazo, R. In SPIE Medical Imaging. 7 (SPIE).