A Comparison of 3 Fixation Strategies in the Treatment of Neer Type IIB Distal Clavicle Fractures.
Journal
Journal of orthopaedic trauma
ISSN: 1531-2291
Titre abrégé: J Orthop Trauma
Pays: United States
ID NLM: 8807705
Informations de publication
Date de publication:
Aug 2020
Aug 2020
Historique:
pubmed:
3
3
2020
medline:
22
6
2021
entrez:
3
3
2020
Statut:
ppublish
Résumé
To compare the stability of NT2B clavicle fractures fixed with either a hook plating (HP), Superior Plating with Suture Augmentation (SPSA), or dual orthogonal plating (DP) with the hypothesis that DP would provide increased multiplanar stability across NT2B fractures. NT2B distal clavicle fractures were created in cadaveric specimens and fixed using (1) HP, (2) SPSA, or (3) DP. Specimens were cyclically loaded in 3 different planes of motion: (1) anteroposterior (AP), (2) superior-inferior, and (3) axial rotation while displacement was continually recorded. Afterward, a superiorly directed load was applied to the clavicle. Load to failure, stiffness, and mode of failure were recorded. During AP loading, clavicles fixed with a DP had significantly lower mean posterior displacement compared to those fixed with SPSA at every 100-cycle interval of testing, P < 0.01. During inferior-superior loading, specimens fixed with a DP had less superior displacement than specimens fixed with an HP and SPSA, reaching significance at the 500-700 cycles of testing. There was no significant difference in axial rotation stability or load to failure between the 3 fixation techniques. Orthogonally placed minifragment plates provide improved stability against anterior displacement with no significant difference in superior stability, axial rotational stability, stiffness, or load to failure. Further clinical studies are needed to confirm the long-term stability of dual plating and determine the risks and benefits of this novel method of distal clavicle fixation.
Identifiants
pubmed: 32118623
doi: 10.1097/BOT.0000000000001752
pii: 00005131-202008000-00013
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e266-e271Références
Rokito AS, Zuckerman JD, Shaari JM, et al. A comparison of nonoperative and operative treatment of type II distal clavicle fractures. Bull Hosp Joint Dis. 2002;61:32–39.
Oh JH, Kim SH, Lee JH, et al. Treatment of distal clavicle fracture: a systematic review of treatment modalities in 425 fractures. Arch Orthop Trauma Surg. 2011;131:525–533.
Nordqvist A, Petersson C, Redlund-Johnell I. The natural course of lateral clavicle fracture. 15 (11-21) year follow-up of 110 cases. Acta Orthop Scand. 1993;64:87–91.
NEER CS. Fracture of the distal clavicle with detachment of the coracoclavicular ligaments in adults. J Trauma. 1963;3:99–110.
Robinson CM, Court-Brown CM, McQueen MM, et al. Estimating the risk of nonunion following nonoperative treatment of a clavicular fracture. J Bone Joint Surg Am. 2004;86:1359–1365.
Fukuda K, Craig EV, An KN, et al. Biomechanical study of the ligamentous system of the acromioclavicular joint. J Bone Joint Surg Ser A. 1986;68:434–440.
Ludewig PM, Phadke V, Braman JP, et al. Motion of the shoulder complex during multiplanar humeral elevation. J Bone Joint Surg Ser A. 2009;91:378–389.
Mazzocca AD, Arciero RA, Bicos J. Evaluation and treatment of acromioclavicular joint injuries. Am J Sports Med. 2007;35:316–329.
Rieser GR, Edwards K, Gould GC, et al. Distal-third clavicle fracture fixation: a biomechanical evaluation of fixation. J Shoulder Elb Surg. 2013;22:848–855.
Good DW, Lui DF, Leonard M, et al. Clavicle hook plate fixation for displaced lateral-third clavicle fractures (Neer type II): a functional outcome study. J Shoulder Elb Surg. 2012;21:1045–1048.
Tambe AD, Motkur P, Qamar A, et al. Fractures of the distal third of the clavicle treated by hook plating. Int Orthop. 2006;30:7–10.
Stegeman SA, Nacak H, Huvenaars KHJ, et al. Surgical treatment of Neer type-II fractures of the distal clavicle: a meta-analysis. Acta Orthop. 2013;84:184–190.
Lin HY, Wong PK, Ho WP, et al. Clavicular hook plate may induce subacromial shoulder impingement and rotator cuff lesion—dynamic sonographic evaluation. J Orthop Surg Res. 2014;9:6.
ElMaraghy AW, Devereaux MW, Ravichandiran K, et al. Subacromial morphometric assessment of the clavicle hook plate. Injury. 2010;41:613–619.
Yan HW, Li L, Wang RC, et al. Clinical efficacies of coracoclavicular ligament reconstruction using suture anchor versus hook plate in the treatment of distal clavicle fracture. Orthop Traumatol Surg Res. 2017;103:1287–1293.
Renger RJ, Roukema GR, Reurings JC, et al. The clavicle hook plate for neer type II lateral clavicle fractures. J Orthop Trauma. 2009;23:570–574.
Zhang LL, Xiao H, Gao Y, et al. Late function and complications of hook plate implantation for distal-third clavicle fractures: a retrospective study. Acta Orthop Belg. 2017;83:304–309.
Zhang C, Huang J, Luo Y, et al. Comparison of the efficacy of a distal clavicular locking plate versus a clavicular hook plate in the treatment of unstable distal clavicle fractures and a systematic literature review. Int Orthop. 2014;38:1461–1468.
Andersen JR, Willis MP, Nelson R, et al. Precontoured superior locked plating of distal clavicle fractures: a new strategy. Clin Orthop Relat Res. 2011;469:3344–3350.
Fleming MA, Dachs R, Maqungo S, et al. Angular stable fixation of displaced distal-third clavicle fractures with superior precontoured locking plates. J Shoulder Elb Surg. 2015;24:700–704.
Johnston PS, Sears BW, Lazarus MR, et al. Fixation of unstable type II clavicle fractures with distal clavicle plate and suture button. J Orthop Trauma. 2014;28:e269–e272.
Shin SJ, Ko YW, Lee J, et al. Use of plate fixation without coracoclavicular ligament augmentation for unstable distal clavicle fractures. J Shoulder Elb Surg. 2016;25:942–948.
Madsen W, Yaseen Z, Lafrance R, et al. Addition of a suture anchor for coracoclavicular fixation to a superior locking plate improves stability of type IIB distal clavicle fractures. Arthrosc J Arthrosc Relat Surg. 2013;29:998–1004.
Milewski MD, Tompkins M, Giugale JM, et al. Complications related to anatomic reconstruction of the coracoclavicular ligaments. Am J Sports Med. 2012;40:1628–1634.
Motta P, Bruno L, Maderni A, et al. Acute lateral dislocated clavicular fractures: arthroscopic stabilization with TightRope. J Shoulder Elb Surg. 2014;23:e47–e52.
Gerhardt DC, VanDerWerf JD, Rylander LS, et al. Postoperative coracoid fracture after transcoracoid acromioclavicular joint reconstruction. J Shoulder Elb Surg. 2011;20:e6–e10.
Martetschläger F, Horan MP, Warth RJ, et al. Complications after anatomic fixation and reconstruction of the coracoclavicular ligaments. Am J Sport Med. 2013;41:2896–2903.
Prasarn ML, Meyers KN, Wilkin G, et al. Dual mini-fragment plating for midshaft clavicle fractures: a clinical and biomechanical investigation. Arch Orthop Trauma Surg. 2015;135:1655–1662.
Sadiq S, Waseem M, Peravalli B, et al. Single or double plating for nonunion of the clavicle. Acta Orthop Belg. 2001;67:354–360.
Prasarn ML, Ahn J, Paul O, et al. Dual plating for fractures of the distal third of the humeral shaft. J Orthop Trauma. 2011;25:57–63.
Higgins TF, Klatt J, Bachus KN. Biomechanical analysis of bicondylar tibial plateau fixation: how does lateral locking plate fixation compare to dual plate fixation? J Orthop Trauma. 2007;21:301–306.
Lädermann A, Gueorguiev B, Stimec B, et al. Acromioclavicular joint reconstruction: a comparative biomechanical study of three techniques. J Shoulder Elb Surg. 2013;22:171–178.
Wilkerson J, Paryavi E, Kim H, et al. Biomechanical comparison of superior versus anterior plate position for fixation of distal clavicular fractures: a new model. J Orthop Trauma. 2017;31:e13–e17.
Bishop JY, Roesch M, Lewis B, et al. A biomechanical comparison of distal clavicle fracture reconstructive techniques. Am J Orthop (Belle Mead Nj). 2013;42:114–118.
Scolaro JA, Hsu JE, Svach DJ, et al. Plate selection for fixation of extra-articular distal humerus fractures: a biomechanical comparison of three different implants. Injury. 2014;45:2040–2044.
Goswami T, Markert RJ, Anderson CG, et al. Biomechanical evaluation of a pre-contoured clavicle plate. J Shoulder Elb Surg. 2008;17:815–818.
Celestre P, Roberston C, Mahar A, et al. Biomechanical evaluation of clavicle fracture plating techniques: does a locking plate provide improved stability? J Orthop Trauma. 2008;22:241–247.
Kim YS, Yoo YS, Jang SW, et al. In vivo analysis of acromioclavicular joint motion after hook plate fixation using three-dimensional computed tomography. J Shoulder Elb Surg. 2015;24:1106–1111.
Martetschläger F, Saier T, Weigert A, et al. Effect of coracoid drilling for acromioclavicular joint reconstruction techniques on coracoid fracture risk: a biomechanical study. Arthrosc J Arthrosc Relat Surg. 2016;32:982–987.
Turman KA, Miller CD, Miller MD. Clavicular fractures following coracoclavicular ligament reconstruction with tendon graft: a report of three cases. J Bone Joint Surg Am. 2010;92:1526–1532.