Evaluation of selected pharmaceuticals and personal care products in water matrix using ion trap mass spectrometry: A simple weighted calibration curve approach.


Journal

Journal of pharmaceutical and biomedical analysis
ISSN: 1873-264X
Titre abrégé: J Pharm Biomed Anal
Pays: England
ID NLM: 8309336

Informations de publication

Date de publication:
05 Jun 2020
Historique:
received: 23 01 2020
revised: 25 02 2020
accepted: 26 02 2020
pubmed: 4 3 2020
medline: 2 3 2021
entrez: 4 3 2020
Statut: ppublish

Résumé

A novel analytical method is presented for 12 target pharmaceutical and personal care products (PPCPs), belonging to different classes like antibiotics, non-steroid anti-inflammatory drugs, parabens, UV-filters, plasticizer, and antibacterials. The method development comprises of solid-phase extraction (SPE) with lipophilic-hydrophilic material balanced Oasis HLB cartridge, followed by reverse-phase liquid chromatography interfaced to linear ion trap tandem mass spectrometry (LC-MS/MS) with electrospray ionization. Chromatographic separation was achieved with a gradient elution of 25 min run time using 5 mM ammonium acetate buffer with pH adjustment using acetic acid. In addition, cost effective organic solvent with buffer used together as the mobile phase with Chromatopak C

Identifiants

pubmed: 32126444
pii: S0731-7085(20)30199-0
doi: 10.1016/j.jpba.2020.113214
pii:
doi:

Substances chimiques

Anti-Bacterial Agents 0
Anti-Inflammatory Agents, Non-Steroidal 0
Cosmetics 0
Parabens 0
Plasticizers 0
Water Pollutants, Chemical 0
Water 059QF0KO0R

Types de publication

Journal Article Validation Study

Langues

eng

Sous-ensembles de citation

IM

Pagination

113214

Informations de copyright

Copyright © 2020 Elsevier B.V. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of Competing Interest No conflict of interest was reported by the authors.

Auteurs

Chikmagalur Mallappa Gopal (CM)

Department of Civil Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, 576104, India.

Krishnamurthy Bhat (K)

Department of Pharmaceutical Quality Assurance, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal, 576104, India.

Yerabham Praveenkumarreddy (Y)

Department of Civil Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, 576104, India.
Department of Gastroenterology and Hepatology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, 576104, India.

Virendra Kumar (V)

Radiation Technology Development Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India.

Hirakendu Basu (H)

Analytical Chemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India.

Derrick Ian Joshua (DI)

Department of Environment sustainability, Manipal Academy of Higher Education, Manipal, 576104, India.

Rakesh Kumar Singhal (RK)

Analytical Chemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India.

Keshava Balakrishna (K)

Department of Civil Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, 576104, India. Electronic address: k.balakrishna@manipal.edu.

Articles similaires

Vancomycin-associated DRESS demonstrates delay in AST abnormalities.

Ahmed Hussein, Kateri L Schoettinger, Jourdan Hydol-Smith et al.
1.00
Humans Drug Hypersensitivity Syndrome Vancomycin Female Male
Humans Arthroplasty, Replacement, Elbow Prosthesis-Related Infections Debridement Anti-Bacterial Agents
Animals Dietary Fiber Dextran Sulfate Mice Disease Models, Animal
Vancomycin Polyesters Anti-Bacterial Agents Models, Theoretical Drug Liberation

Classifications MeSH