Computational modeling of drug transport and mixing in the chemofilter device: enhancing the removal of chemotherapeutics from circulation.
Adsorption
Computational fluid dynamics
Convection–diffusion
Drug transport
Hemodynamics
Intra-arterial chemotherapy
Mass transfer
Medical device
Multiphysics modeling
Journal
Biomechanics and modeling in mechanobiology
ISSN: 1617-7940
Titre abrégé: Biomech Model Mechanobiol
Pays: Germany
ID NLM: 101135325
Informations de publication
Date de publication:
Oct 2020
Oct 2020
Historique:
received:
06
09
2019
accepted:
17
02
2020
pubmed:
14
3
2020
medline:
28
7
2021
entrez:
14
3
2020
Statut:
ppublish
Résumé
Intra-arterial chemotherapy (IAC) is the preferred treatment for non-resectable hepatocellular carcinoma. A large fraction of IAC drugs, e.g., Doxorubicin, pass into systemic circulation, causing cardiac toxicity and reducing effectiveness of the procedure. These excessive drugs can be captured by the Chemofilter-a 3D-printable, catheter-based device deployed in a vein downstream of the liver during IAC. In this study, alternative configurations of the Chemofilter device were compared by evaluating their hemodynamic and filtration performance through multiphysics computational fluid dynamics simulations. Two designs were evaluated, a honeycomb-like structure of parallel hexagonal channels (honeycomb Chemofilter) and a cubic lattice of struts (strutted Chemofilter). The computationally optimized Chemofilter design contains three honeycomb stages, each perforated and twisted, which improved Doxorubicin adsorption by 44.6% compared to a straight channel design. The multiphysics simulations predicted an overall 66.8% decrease in concentration with a 2.9 mm-Hg pressure drop across the optimized device compared to a 50% concentration decrease observed during in-vivo experiments conducted with the strutted Chemofilter. The Doxorubicin transport simulations demonstrated the effectiveness of the Chemofilter in removing excessive drugs from circulation while minimizing pressure drop and eliminating flow stagnation regions prone to thrombosis. These results demonstrate the value of the multiphysics modeling approach in device optimization and experimental burden reduction.
Identifiants
pubmed: 32166531
doi: 10.1007/s10237-020-01313-8
pii: 10.1007/s10237-020-01313-8
doi:
Substances chimiques
Antineoplastic Agents
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1865-1877Subventions
Organisme : NCI NIH HHS
ID : R01CA194533
Pays : United States
Organisme : NCI NIH HHS
ID : R01CA194533
Pays : United States