A comparative evaluation of the efficacy of erbium: yttrium-aluminum-garnet and diode lasers in smear layer removal and dentin permeability of root canal after biomechanical preparation - A scanning electron microscopy study.
17% ethylenediaminetetraacetic acid
diode laser
erbium:yttrium–aluminum–garnet laser
hand and rotary instruments
root canal preparation
scanning electron microscope
smear layer
Journal
Journal of the Indian Society of Pedodontics and Preventive Dentistry
ISSN: 1998-3905
Titre abrégé: J Indian Soc Pedod Prev Dent
Pays: India
ID NLM: 8710631
Informations de publication
Date de publication:
Historique:
entrez:
17
3
2020
pubmed:
17
3
2020
medline:
18
3
2020
Statut:
ppublish
Résumé
The chemomechanical preparation of root canal dentin with hand or rotary instruments creates debris and a smear layer. Root canal preparation (RCP) along with irrigants is not effective in cleaning apical portions, and hence, different laser activation systems were used for better cleaning in the apical third. Aim: The aim of this study is to compare the efficacy of erbium: yttrium-aluminum-garnet (Er:YAG) and diode laser irradiation in smear layer removal and dentin permeability after biomechanical preparation using scanning electron microscopic investigation. Material and Methods: Thirty sound single-rooted human teeth were distributed randomly and equally into three groups (n = 10 each) based upon the type of laser irradiation after RCP: Group I (control group) - RCP with ProTaper rotary system using the standard irrigating protocol; Group II - RCP with ProTaper rotary system using the standard irrigating protocol followed by diode laser irradiation; and Group III - RCP with ProTaper rotary system using the standard irrigating protocol followed by Er:YAG laser irradiation. After root sectioning, specimens were dehydrated, then gold plated and observed using a scanning electron microscopy. Then, the smear layer scores were recorded and performed using the statistical analysis. Results: Smear layer removal efficacy of Er:YAG laser was more at coronal, middle, and apical third when compared to Group I and Group II. Debris removal score of Group III (Er:YAG) was better than Group I (17% ethylenediaminetetraacetic acid) and Group II (diode). Conclusion: Er:YAG laser-activated RCP was comparatively efficient in cleaning the smear layer and dentinal tubules opening.
Identifiants
pubmed: 32174631
pii: JIndianSocPedodPrevDent_2020_38_1_64_280508
doi: 10.4103/JISPPD.JISPPD_174_19
doi:
Substances chimiques
Root Canal Irrigants
0
yttrium-aluminum-garnet
0
Yttrium
58784XQC3Y
Erbium
77B218D3YE
Aluminum
CPD4NFA903
Types de publication
Journal Article
Langues
eng
Pagination
64-70Déclaration de conflit d'intérêts
None