A novel endoscopic hand-suturing technique for defect closure after colorectal endoscopic submucosal dissection: a pilot study.
Journal
Endoscopy
ISSN: 1438-8812
Titre abrégé: Endoscopy
Pays: Germany
ID NLM: 0215166
Informations de publication
Date de publication:
09 2020
09 2020
Historique:
pubmed:
25
3
2020
medline:
16
2
2021
entrez:
25
3
2020
Statut:
ppublish
Résumé
This study aimed to demonstrate the feasibility of endoscopic hand-suturing (EHS) and attainability of sustained closure after colorectal endoscopic submucosal dissection (ESD). EHS was defined as uninterrupted endoscopic suturing of the mucosal defect after colorectal ESD using an absorbable barbed suture and a through-the-scope needle holder. Following individual EHS training using an ex vivo porcine colonic model, two experienced endoscopists performed EHS. Repeat colonoscopy was performed on the third or fourth day after ESD to examine the EHS site. The primary end point was the complete EHS closure rate, and secondary end points were sustained closure and post-ESD bleeding rates. 11 lesions were included. Median size of the mucosal defect was 38 mm (range 25 - 55 mm) and the lesion characteristics were as follows: lower rectum/upper rectum/ascending colon/cecum = 3/3/2/3, and 0-IIa/0-Is + IIa/others = 5/4/2. EHS was not attempted in two patients owing to difficulty in colonoscope reinsertion after ESD and intraoperative perforation, respectively. EHS was performed for nine lesions, and the complete EHS closure rate was 73 %. Median procedure time for suturing was 56 minutes (range 30 - 120 minutes) and median number of stitches was 8 (range 6 - 12). Sustained closure and post-ESD bleeding rates were 64 % and 9 %, respectively. EHS achieved complete and sustained closure in the colorectum. However, EHS is not currently clinically applicable given the long procedure time. Further modifications of the technique and devices are desirable.
Sections du résumé
BACKGROUND
This study aimed to demonstrate the feasibility of endoscopic hand-suturing (EHS) and attainability of sustained closure after colorectal endoscopic submucosal dissection (ESD).
METHODS
EHS was defined as uninterrupted endoscopic suturing of the mucosal defect after colorectal ESD using an absorbable barbed suture and a through-the-scope needle holder. Following individual EHS training using an ex vivo porcine colonic model, two experienced endoscopists performed EHS. Repeat colonoscopy was performed on the third or fourth day after ESD to examine the EHS site. The primary end point was the complete EHS closure rate, and secondary end points were sustained closure and post-ESD bleeding rates.
RESULTS
11 lesions were included. Median size of the mucosal defect was 38 mm (range 25 - 55 mm) and the lesion characteristics were as follows: lower rectum/upper rectum/ascending colon/cecum = 3/3/2/3, and 0-IIa/0-Is + IIa/others = 5/4/2. EHS was not attempted in two patients owing to difficulty in colonoscope reinsertion after ESD and intraoperative perforation, respectively. EHS was performed for nine lesions, and the complete EHS closure rate was 73 %. Median procedure time for suturing was 56 minutes (range 30 - 120 minutes) and median number of stitches was 8 (range 6 - 12). Sustained closure and post-ESD bleeding rates were 64 % and 9 %, respectively.
CONCLUSIONS
EHS achieved complete and sustained closure in the colorectum. However, EHS is not currently clinically applicable given the long procedure time. Further modifications of the technique and devices are desirable.
Banques de données
UMIN-CTR
['UMIN000031512']
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
780-785Commentaires et corrections
Type : CommentIn
Informations de copyright
© Georg Thieme Verlag KG Stuttgart · New York.
Déclaration de conflit d'intérêts
The study was supported by Olympus Corp.