Effects of a novel medial meniscus implant on the knee compartments: imaging and biomechanical aspects.
Adult
Biomechanical Phenomena
Cadaver
Cartilage, Articular
/ surgery
Female
Humans
Knee Joint
/ diagnostic imaging
Magnetic Resonance Imaging
Male
Meniscectomy
/ methods
Menisci, Tibial
/ diagnostic imaging
Middle Aged
Osteoarthritis, Knee
/ diagnostic imaging
Pressure
Prostheses and Implants
Prosthesis Design
Range of Motion, Articular
Stress, Mechanical
Tibia
/ physiopathology
Weight-Bearing
Cadaver
Knee
Meniscetomy
Osteoarthritis
Pressure distribution
Prosthesis
Journal
Biomechanics and modeling in mechanobiology
ISSN: 1617-7940
Titre abrégé: Biomech Model Mechanobiol
Pays: Germany
ID NLM: 101135325
Informations de publication
Date de publication:
Dec 2020
Dec 2020
Historique:
received:
18
08
2019
accepted:
20
03
2020
pubmed:
3
4
2020
medline:
24
8
2021
entrez:
3
4
2020
Statut:
ppublish
Résumé
The altered biomechanical function of the knee following partial meniscectomy results in ongoing articular cartilage overload, which may lead to progressive osteoarthritis (OA). An artificial medial meniscus implant (NUsurface
Identifiants
pubmed: 32236747
doi: 10.1007/s10237-020-01323-6
pii: 10.1007/s10237-020-01323-6
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
2049-2059Subventions
Organisme : Active Implants LLC
ID : Not applicable
Références
Allaire R, Muriuki M, Gilbertson L, Harner CD (2008) Biomechanical consequences of a tear of the posterior root of the medial meniscus: similar to total meniscectomy. J Bone Joint Surg Am 90:1922–1931
doi: 10.2106/JBJS.G.00748
Allen PR, Denham RA, Swan AV (1984) Late degenerative changes after meniscectomy. Factors affecting the knee after operation. J Bone Joint Surg Br 66:666–671
doi: 10.1302/0301-620X.66B5.6548755
Cullen KA, Hall MJ, Golosinskiy A (2009) Ambulatory surgery in the united states, 2006. Natl Health Stat Report, 1–25
Elsner JJ, Portnoy S, Zur G, Guilak F, Shterling A, Linder-Ganz E (2010) Design of a free-floating polycarbonate-urethane meniscal implant using finite element modeling and experimental validation. J Biomech Eng 132(9):095001
doi: 10.1115/1.4001892
Englund M, Lohmander LS (2004) Risk factors for symptomatic knee osteoarthritis fifteen to twenty-two years after meniscectomy. Arthritis Rheum 50:2811–2819
doi: 10.1002/art.20489
Englund M, Lohmander LS (2005) Meniscectomy is associated with the development of osteoarthritis not only in the ipsilateral tibiofemoral joint, but also the patellofemoral joint, and the contra lateral tibiofemoral joint. In: 51st annual meeting of the orthopaedic research society. Washington, D.C., February 20–23
Fairbank TJ (1948) Knee joint changes after meniscectomy. JBJS Br 30B:664–670
Fukubayashi T, Kurosawa H (1980) The contact area and pressure distribution pattern of the knee Acta Orthop. Scand 51:871–879
Getgood A, LaPrade RF, Verdonk P, Gersoff W, Cole B, Spalding T, IMREF Group (2016) International meniscus reconstruction experts forum (IMREF) 2015 consensus statement on the practice of meniscal allograft transplantation. Am J Sports Med 45(5):1195–1205
Holloway JL, Lowman AM, Palmese GR (2010) Mechanical evaluation of poly (vinyl alcohol)-based fibrous composites as biomaterials for meniscal tissue replacement. Acta Biomater 6:4716–4724
doi: 10.1016/j.actbio.2010.06.025
Hutchinson ID, Moran CJ, Potter HG, Warren RF, Rodeo SA (2014) Restoration of the meniscus: form and function. Am J Sports Med 42:987–998
doi: 10.1177/0363546513498503
Ihn JC, Kim SJ, Park IH (1993) In vitro study of contact area and pressure distribution in the human knee after partial and total meniscectomy. Int Orthop 17(4):214–218
doi: 10.1007/BF00194181
Kelly BT, Robertson W, Potter HG, Deng XH, Turner AS, Lyman S, Warren RF, Rodeo SA (2007) Hydrogel meniscal replacement in the sheep knee: preliminary evaluation of chondroprotective effects. Am J Sports Med 35:43–52
doi: 10.1177/0363546506292848
Lanzer WL, Komenda G (1990) Changes in articular cartilage after meniscectomy. Clin Orthop Relat Res 252:41–48
Lee BS, Chung JW, Kim JM, Cho WJ, Kim KA, Bin SI (2012) Morphologic changes in fresh-frozen meniscus allografts over 1 year: a prospective magnetic resonance imaging study on the width and thickness of transplants. Am J Sports Med 40(6):1384–1391
doi: 10.1177/0363546512442341
Lee SJ, Lee BS, Kim JM, Bin SI (2015) Clinical results of contralateral arthroscopic meniscectomy performed with unilateral total knee arthroplasty: minimum 3-year follow-up. Knee Surg Relat Res 27(2):76–81
doi: 10.5792/ksrr.2015.27.2.76
Linder-Ganz E, Elsner JJ, Danino A, Guilak F, Shterling A (2010) A novel quantitative approach for evaluating contact mechanics of meniscal replacements. J Biomech Eng 132(2):024501
doi: 10.1115/1.4000407
McDermott ID, Amis AA (2006) The consequences of meniscectomy. J Bone Joint Surg Br 88:1549–1556
doi: 10.1302/0301-620X.88B12.18140
Ode GE, Van Thiel GS, McArthur SA, Dishkin-Paset J, Leurgans SE, Shewman EF, Wang VM, Cole BJ (2012) Effects of serial sectioning and repair of radial tears in the lateral meniscus. Am J Sports Med 40(8):1863–1870
doi: 10.1177/0363546512453291
Outerbridge RE (1961) The etiology of chondromalacia patellae. J Bone Joint Surg Br 43:752–757
doi: 10.1302/0301-620X.43B4.752
Papalia R, Del Buono A, Osti L, Denaro V, Maffulli N (2011) Meniscectomy as a risk factor for knee osteoarthritis: a systematic review. Br Med Bull 99(1):89–106
doi: 10.1093/bmb/ldq043
Patil SS, Tapasvi SR, Shekhar A (2016) Meniscectomy-outcomes and complications. Asian J Arthrosc 1:53–55
Peña E, Calvo B, Martínez MA, Palanca D, Doblaré M (2005) Finite element analysis of the effect of meniscal tears and meniscectomies on human knee biomechanics. Clin Biomech 20:498–507
doi: 10.1016/j.clinbiomech.2005.01.009
Rosso F, Bisicchia S, Bonasia DE, Amendola A (2015) Meniscal allograft transplantation: a systematic review. Am J Sports Med 43:998–1007
doi: 10.1177/0363546514536021
Seitz AM, Lubomierski A, Friemert B, Ignatius A, Dürselen L (2012) Effect of partial meniscectomy at the medial posterior horn on tibiofemoral contact mechanics and meniscal hoop strains in human knees. J Orthop Res 30(6):934–942
doi: 10.1002/jor.22010
Shemesh M, Asher R, Zylberberg E, Guilak F, Linder-Ganz E, Elsner JJ (2014) Viscoelastic properties of a synthetic meniscus implant. J Mech Behav Biomed Mater 29:42–55
doi: 10.1016/j.jmbbm.2013.08.021
Shriram D, Praveen Kumar G, Cui F, Lee YHD, Subburaj K (2017) Evaluating the effects of material properties of artificial meniscal implant in the human knee joint using finite element analysis. Sci Rep 20(1):6011
doi: 10.1038/s41598-017-06271-3
Sihvonen R, Paavola M, Malmivaara A, Itala A, Joukainen A, Nurmi H, Kalske J, Jarvinen TL (2013) Arthroscopic partial meniscectomy versus sham surgery for a degenerative meniscal tear. N Engl J Med 369:2515–2524
doi: 10.1056/NEJMoa1305189
Verma NN, Kolb E, Cole BJ, Berkson MB, Garretson R, Farr J, Fregly B (2008) The effects of medial meniscal transplantation techniques on intra-articular contact pressures. J Knee Surg 21(1):20–26
doi: 10.1055/s-0030-1247787
Vrancken ACT, Buma P, van Tienen TG (2013) Synthetic meniscus replacement: a review. Int Orthop 37:291–299
doi: 10.1007/s00264-012-1682-7
Wada Y, Amiel M, Harwood F, Moriya H, Amiel D (1998) Architectural remodeling in deep frozen meniscal allografts after total meniscectomy. Arthroscopy 14:250–257
doi: 10.1016/S0749-8063(98)70140-9
Wang H, Chen T, Gee AO, Hutchinson ID, Stoner K, Warren RF, Rodeo RA, Maher SA (2015) Altered regional loading patterns on articular cartilage following meniscectomy are not fully restored by autograft meniscal transplantation. Osteoarthr Cartil 23:462–468
doi: 10.1016/j.joca.2014.12.003
Welsing RT, van Tienen TG, Ramrattan N, Heijkants R, Schouten AJ, Veth RP, Buma P (2008) Effect on tissue differentiation and articular cartilage degradation of a polymer meniscus implant: a 2-year follow-up study in dogs. Am J Sports Med 36:1978–1989
doi: 10.1177/0363546508319900
Wilson W, van Donkelaar C, van Rietbergen B, Huiskes R (2003) Pathways of load-induced cartilage damage causing degeneration in the knee after meniscectomy. J Biomech 36:845–851
doi: 10.1016/S0021-9290(03)00004-6