Résumé
This study aimed to assess the prognostic ability of SYNTAX (Synergy Between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) Score II (SS-II) in LM and/or TVD patients undergoing biodegradable polymer-based drug-eluting stents (BP-DES) in the multi-central randomized PANDA III trial. A total of 723 patients in PANDA III population were enrolled in this study. According to SS-II tertiles, patients were stratified as follow: SS-II ≤ 23 (n = 224), 23 < SS II ≤ 31 (n = 255), SS II > 31 (n = 244). The predictive abilities for 2-year cardiac death were compared between angiographic scores and scores combining both angiographic and clinical variables. Mean anatomic SS was 20.6 ± 9.4, SS-II for PCI was 28.7 ± 8.6. During 2-year follow up, cardiac death (0.00% vs. 1.7% vs. 4.3%, p = 0.003) and target lesion failure (5.9% vs. 9.1% vs. 13.6%, p = 0.020) was significantly higher in the upper tertile group than in intermedian and low tertile. At multivariate analysis, SS-II for PCI was an independent risk factor of cardiac death (Hazard ratio: 2.41, 95%CI: 1.47-3.97, p < 0.005) and TLF (Hazard ratio: 1.29, 95%CI: 1.01-1.65, p = 0.040). The ROC curve analysis showed that SS-II for PCI had better ability than other SYNTAX scoring systems to predict cardiac death (AUC: 0.746, 95%CI:0.63-0.87, p = 0.010). The SS-II had superiority than other SYNTAX scoring systems in predicting 2-year cardiac death in LM and/or TVD patients undergoing PCI with biodegradable polymer drug-eluting stents.
Sections du résumé
BACKGROUND
This study aimed to assess the prognostic ability of SYNTAX (Synergy Between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) Score II (SS-II) in LM and/or TVD patients undergoing biodegradable polymer-based drug-eluting stents (BP-DES) in the multi-central randomized PANDA III trial.
METHODS
A total of 723 patients in PANDA III population were enrolled in this study. According to SS-II tertiles, patients were stratified as follow: SS-II ≤ 23 (n = 224), 23 < SS II ≤ 31 (n = 255), SS II > 31 (n = 244). The predictive abilities for 2-year cardiac death were compared between angiographic scores and scores combining both angiographic and clinical variables.
RESULTS
Mean anatomic SS was 20.6 ± 9.4, SS-II for PCI was 28.7 ± 8.6. During 2-year follow up, cardiac death (0.00% vs. 1.7% vs. 4.3%, p = 0.003) and target lesion failure (5.9% vs. 9.1% vs. 13.6%, p = 0.020) was significantly higher in the upper tertile group than in intermedian and low tertile. At multivariate analysis, SS-II for PCI was an independent risk factor of cardiac death (Hazard ratio: 2.41, 95%CI: 1.47-3.97, p < 0.005) and TLF (Hazard ratio: 1.29, 95%CI: 1.01-1.65, p = 0.040). The ROC curve analysis showed that SS-II for PCI had better ability than other SYNTAX scoring systems to predict cardiac death (AUC: 0.746, 95%CI:0.63-0.87, p = 0.010).
CONCLUSIONS
The SS-II had superiority than other SYNTAX scoring systems in predicting 2-year cardiac death in LM and/or TVD patients undergoing PCI with biodegradable polymer drug-eluting stents.
Identifiants
pubmed: 32238273
pii: S0167-5273(19)34798-9
doi: 10.1016/j.ijcard.2020.02.042
pii:
doi:
Substances chimiques
Polymers
0
Sirolimus
W36ZG6FT64
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
27-32Informations de copyright
Copyright © 2020. Published by Elsevier B.V.
Déclaration de conflit d'intérêts
Declaration of competing interest The PANDA III trial was sponsored by Sino Medical, Tianjin, China. There was no additional funding for the present study. All the authors report no conflicts of interest in regard to this manuscript.