Fretting corrosion of Si


Journal

Journal of orthopaedic research : official publication of the Orthopaedic Research Society
ISSN: 1554-527X
Titre abrégé: J Orthop Res
Pays: United States
ID NLM: 8404726

Informations de publication

Date de publication:
07 2020
Historique:
received: 18 11 2019
revised: 07 02 2020
accepted: 25 03 2020
pubmed: 7 4 2020
medline: 11 11 2020
entrez: 7 4 2020
Statut: ppublish

Résumé

Fretting corrosion at the head-neck taper junction was compared between silicon nitride (Si

Identifiants

pubmed: 32249959
doi: 10.1002/jor.24681
doi:

Substances chimiques

Alloys 0
Silicon Compounds 0
Vitallium 12629-02-6
titanium alloy (TiAl6V4) 12743-70-3
Titanium D1JT611TNE
silicon nitride QHB8T06IDK

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

1617-1626

Informations de copyright

© 2020 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Références

Patterson SP, Daffner RH, Gallo RA. Electrochemical corrosion of metal implants. Am J Roentgenol. 2005;184(4):1219-1222.
Gilbert JL. Electrochemical behavior of metals in the biological milieu. Compr. Biomater. 2011:21-48.
Yaszemski M, Trantolo D, Lewandrowski KU, et al. Corrosion and Biocompatibility of Orthopedic Implants. In: Yaszemski MJ, ed. Biomaterials in Orthopedics. Boca Raton, FL: CRC Press; 2003:63-91.
Gilbert JL. Corrosion in the human body: metallic implants in the complex body environment. Corrosion. 2017;73(12):1478-1495.
Gkagkalis G, Mettraux P, Omoumi P, Mischler S, Rüdiger HA. Adverse tissue reaction to corrosion at the neck-stem junction after modular primary total hip arthroplasty. Orthop Traumatol Surg Res. 2015;101(1):123-126.
Pearson MJ, Williams RL, Floyd H, et al. The effects of cobalt-chromium-molybdenum wear debris in vitro on serum cytokine profiles and T cell repertoire. Biomaterials. 2015;67:232-239.
Gibon E, Amanatullah DF, Loi F, et al. The biological response to orthopaedic implants for joint replacement: part I: metals. J Biomed Mater Res B Appl Biomater. 2017;105(7):2162-2173.
Cook RB, Bolland BJRF, Wharton JA, Tilley S, Latham JM, Wood RJK. Pseudotumour formation due to tribocorrosion at the taper interface of large diameter metal on polymer modular total hip replacements. J Arthroplasty. 2013;28(8):1430-1436.
Doorn PF, Mirra JM, Campbell PA, Amstutz HC. Tissue reaction to metal on metal total hip prostheses. Clin Orthop. 1996;329(329 suppl):S187-S205.
Gilbert JL, Buckley CA, Jacobs JJ. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. J Biomed Mater Res. 1993;27(12):1533-1544.
Goldberg JR, Gilbert JL, Jacobs JJ, Bauer TW, Paprosky W, Leurgans S. A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop. 2002;401:149-161.
Atwood SA, Patten EW, Bozic KJ, Pruitt LA, Ries MD. Corrosion-induced fracture of a double-modular hip prosthesis: a case report. J Bone Jt Surg. 2010;92(6):1522-1525.
Grupp TM, Weik T, Bloemer W, Knaebel H-P. Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material. BMC Musculoskelet Disord. 2010;11(1):3.
Capello WN, D'Antonio JA, Feinberg JR, Manley MT, Naughton M. Ceramic-on-ceramic total hip arthroplasty: update. J Arthroplasty. 2008;23(7 suppl):39-43.
Zhou YS, Ikeuchi K, Ohashi M. Comparison of the friction properties of four ceramic materials for joint replacements. Wear. 1997;210(1):171-177.
Hallab NJ, Messina C, Skipor A, Jacobs JJ. Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements. J Orthop Res. 2004;22(2):250-259.
Barrack RL, Burak C, Skinner HB. Concerns about ceramics in THA. Clin Orthop Relat Res. 2004;429:73-79.
Guedes e Silva CC, Higa OZ, Bressiani JC. Cytotoxic evaluation of silicon nitride-based ceramics. Mater Sci Eng C. 2004;24(5):643-646.
Howlett CR, McCartney E, Ching W. The effect of silicon nitride ceramic on rabbit skeletal cells and tissue. An in vitro and in vivo investigation. Clin Orthop. 1989;244:293-304.
Rambo WM. Treatment of lumbar discitis using silicon nitride spinal spacers: a case series and literature review. Int J Surg Case Rep. 2018;43:61-68.
Boschetto F, Bock R, McEntire B, et al. Hinderance of bacterial proliferation by a silicon nitride surface buffering effect. 2019.
Zhou YS, Ohashi M, Tomita N, Ikeuchi K, Takashima K. Study on the possibility of silicon nitride-silicon nitride as a material for hip prostheses. Mater Sci Eng C. 1997;5(2):125-129.
Bal BS, Khandkar A, Lakshminarayanan R, Clarke I, Hoffman AA, Rahaman MN. Testing of silicon nitride ceramic bearings for total hip arthroplasty. J Biomed Mater Res B Appl Biomater. 2008;87(2):447-454.
F04 Committee. [date unknown]. Specification for wrought Cobalt-28Chromium-6Molybdenum alloys for surgical implants (UNS R31537, UNS R31538, and UNS R31539). ASTM International.
Pierre D, Swaminathan V, Scholl L, TenHuisen K, Gilbert JL. Effects of seating load magnitude and load orientation on seating mechanics in 5°40′ mixed-alloy modular taper junctions. J Biomech. 2019;82:251-258.
Goldberg JR, Gilbert JL. In vitro corrosion testing of modular hip tapers. J Biomed Mater Res B Appl Biomater. 2003;64B(2):78-93.
F04 Committee. [date unknown]. Test method for determining the axial disassembly force of taper connections of modular prostheses. ASTM International.
Goldberg JR, Gilbert JL. Electrochemical response of CoCrMo to high-speed fracture of its metal oxide using an electrochemical scratch test method. J Biomed Mater Res. 1997;37(3):421-431.
Gilbert J, Buckley C, Lautenschlager E. Titanium Oxide Film Fracture and Repassivation: The Effect of Potential, pH and Aeration. In: Brown S, Lemons J, eds. Medical Applications of Titanium and Its Alloys: The Material and Biological Issues. West Conshohocken, PA: ASTM International; 1996.
Rowan FE, Wach A, Wright TM, Padgett DE. The onset of fretting at the head-stem connection in hip arthroplasty is affected by head material and trunnion design under simulated corrosion conditions. J Orthop Res. 2018;36(6):1630-1636.
Kyomoto M, Shoyama Y, Saiga K, Moro T, Ishihara K. Reducing fretting-initiated crevice corrosion in hip simulator tests using a zirconia-toughened alumina femoral head. J Biomed Mater Res B Appl Biomater. 2018;106(8):2815-2826.
Kocagoz SB, Underwood RJ, MacDonald DW, Gilbert JL, Kurtz SM. Ceramic heads decrease metal release caused by head-taper fretting and corrosion. Clin Orthop. 2016;474(4):985-994.
Bergmann G, Bender A, Dymke J, Duda G, Damm P. Standardized loads acting in hip implants. PLOS One. 2016;11(5):e0155612.
Ouellette ES, Mali SA, Kim J, Grostefon J, Gilbert JL. Design, material, and seating load effects on in vitro fretting corrosion performance of modular head-neck tapers. J Arthroplasty. 2019;34(5):991-1002.
Gilbert JL, Mali SA, Sivan S. Corrosion of Modular Tapers in Total Joint Replacements: A Critical Assessment of Design, Materials, Surface Structure, Mechanics, Electrochemistry, and Biology. In: Greenwald AS, Kurtz SM, Lemons JE, Mihalko WM, eds. Modularity and Tapers in Total Joint Replacement Devices. West Conshohocken, PA: ASTM International; 2015:192-223. http://www.astm.org/doiLink.cgi?STP159120140135
Khullar P, Zhu D, Gilbert JL. [date unknown]. Modular head-neck taper fretting mechanics: Si3N4 vs CoCrMo head on Ti-6Al-4V trunnion.
Langton DJ, Sidaginamale R, Lord JK, Nargol AVF, Joyce TJ. Taper junction failure in large-diameter metal-on-metal bearings. Bone Jt. Res. 2012;1(4):56-63.
Panagiotidou A, Meswania J, Hua J, Muirhead-Allwood S, Hart A, Blunn G. Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography. J Orthop Res. 2013;31(12):2032-2039.
Pourzal R, Hall DJ, Ha NQ, et al. Does surface topography play a role in taper damage in head-neck modular junctions? Clin Orthop. 2016;474(10):2232-2242.
Moharrami N, Langton DJ, Sayginer O, Bull SJ. Why does titanium alloy wear cobalt chrome alloy despite lower bulk hardness: a nanoindentation study? Thin Solid Films. 2013;549:79-86.
Hall DJ, Pourzal R, Lundberg HJ, Mathew MT, Jacobs JJ, Urban RM. Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements. J Biomed Mater Res B Appl Biomater. 2018;106(5):1672-1685.
Arnholt CM, MacDonald DW, Underwood RJ, et al. Do stem taper microgrooves influence taper corrosion in total hip arthroplasty? A matched cohort retrieval study. J Arthroplasty. 2017;32(4):1363-1373.

Auteurs

Piyush Khullar (P)

Clemson-MUSC Bioengineering Program, Charleston, South Carolina.
Department of Bioengineering, Clemson University, Clemson, South Carolina.

Dongkai Zhu (D)

Clemson-MUSC Bioengineering Program, Charleston, South Carolina.
Department of Bioengineering, Clemson University, Clemson, South Carolina.

Jeremy L Gilbert (JL)

Clemson-MUSC Bioengineering Program, Charleston, South Carolina.
Department of Bioengineering, Clemson University, Clemson, South Carolina.
Orthopaedics and Physical Medicine, Medical University of South Carolina, Charleston, South Carolina.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH