Pressure Differences from Clear Aligner Movements Assessed by Pressure Sensors.


Journal

BioMed research international
ISSN: 2314-6141
Titre abrégé: Biomed Res Int
Pays: United States
ID NLM: 101600173

Informations de publication

Date de publication:
2020
Historique:
received: 24 10 2019
accepted: 11 02 2020
entrez: 8 4 2020
pubmed: 8 4 2020
medline: 17 12 2020
Statut: epublish

Résumé

In this study, a clear aligner was moved at intervals of 0.25 mm and pressure variations were assessed using a sensor. The model used for producing the clear aligner was created using a 3-dimensional printer. A clear, circular thermoplastic of 0.75 mm thickness was used for making the clear aligner using the vacuum forming method. A pressure sensor was used to assess the pressure in the device, and the variation in the sheet pressure was statistically analyzed tooth movement using the clear aligner, moving at an interval of 0.25 mm, is recommended. The results of pressure sensor assessment showed that the pressure of the devices with 0.25 mm and 1.00 mm movements was identical to that of the device with 0 mm movement. In other words, the pressure sensor could not distinguish the pressure of devices that moved 0.25 mm and 1.00 mm. This experiment demonstrated that a movement of more than 0.50 mm is needed to apply the appropriate pressures needed for orthodontics in a clear polymer sheet.

Identifiants

pubmed: 32258149
doi: 10.1155/2020/8376395
pmc: PMC7091522
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

8376395

Informations de copyright

Copyright © 2020 Ho-jung Son et al.

Déclaration de conflit d'intérêts

The authors declare that they have no conflicts of interest.

Références

Am J Orthod Dentofacial Orthop. 2007 Nov;132(5):579-85
pubmed: 18005830
Am J Orthod Dentofacial Orthop. 2007 Mar;131(3):302.e1-9
pubmed: 17346581
J Clin Orthod. 1998 Feb;32(2):95-7
pubmed: 9709631
J Oral Rehabil. 2015 Jan;42(1):34-9
pubmed: 25195920
J Orofac Orthop. 2007 May;68(3):223-31
pubmed: 17522806
J Calif Dent Assoc. 2002 Oct;30(10):769-76
pubmed: 12403481
Am J Orthod Dentofacial Orthop. 2019 Jan;155(1):98-107
pubmed: 30591174
J Clin Orthod. 2008 Apr;42(4):237-45
pubmed: 18477839
J Clin Orthod. 1993 Jan;27(1):37-45
pubmed: 8478438
Aust Orthod J. 2001 Mar;17(1):41-6
pubmed: 11506169

Auteurs

Ho-Jung Son (HJ)

Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University, Seoul, Republic of Korea.

Kyeong-Ho Lee (KH)

School of Electrical Engineering, College of Engineering, Korea University, Seoul, Republic of Korea.

Ji-Young Sim (JY)

Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University, Seoul, Republic of Korea.

Hae-Young Kim (HY)

Department of Public Health Sciences, Graduate School, Korea University, Seoul, Republic of Korea.

Ji-Hwan Kim (JH)

Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University, Seoul, Republic of Korea.

Woong-Chul Kim (WC)

Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University, Seoul, Republic of Korea.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH