A Self-Calibrating IoT Portable Electrochemical Immunosensor for Serum Human Epididymis Protein 4 as a Tumor Biomarker for Ovarian Cancer.
Internet of Things
WiFi portable potentiostat
competitive electrochemical immunosensor
human epididymis protein 4
on-board calibration
Journal
Sensors (Basel, Switzerland)
ISSN: 1424-8220
Titre abrégé: Sensors (Basel)
Pays: Switzerland
ID NLM: 101204366
Informations de publication
Date de publication:
03 Apr 2020
03 Apr 2020
Historique:
received:
09
03
2020
revised:
30
03
2020
accepted:
31
03
2020
entrez:
9
4
2020
pubmed:
9
4
2020
medline:
31
12
2020
Statut:
epublish
Résumé
Nowadays, analytical techniques are moving towards the development of smart biosensing strategies for the point-of-care accurate screening of disease biomarkers, such as human epididymis protein 4 (HE4), a recently discovered serum marker for early ovarian cancer diagnosis. In this context, the present work represents the first implementation of a competitive enzyme-labelled magneto-immunoassay exploiting a homemade IoT Wi-Fi cloud-based portable potentiostat for differential pulse voltammetry readout. The electrochemical device was specifically designed to be capable of autonomous calibration and data processing, switching between calibration, and measurement modes: in particular, firstly, a baseline estimation algorithm is applied for correct peak computation, then calibration function is built by interpolating data with a four-parameter logistic function. The calibration function parameters are stored on the cloud for inverse prediction to determine the concentration of unknown samples. Interpolation function calibration and concentration evaluation are performed directly on-board, thus reducing the power consumption. The analytical device was validated in human serum, demonstrating good sensing performance for analysis of HE4 with detection and quantitation limits in human serum of 3.5 and 29.2 pM, respectively, reaching the sensitivity that is required for diagnostic purposes, with high potential for applications as portable and smart diagnostic tool for point-of-care testing.
Identifiants
pubmed: 32260240
pii: s20072016
doi: 10.3390/s20072016
pmc: PMC7180438
pii:
doi:
Substances chimiques
Biomarkers, Tumor
0
WAP Four-Disulfide Core Domain Protein 2
0
WFDC2 protein, human
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Subventions
Organisme : Università degli Studi di Parma
ID : FIL 2016-Quota Incentivante
Organisme : Ministero dell'Istruzione, dell'Università e della Ricerca
ID : Department of Excellence COMP-HUB
Références
Clin Chim Acta. 2013 Jan 16;415:341-5
pubmed: 23165217
Biosens Bioelectron. 2017 Jan 15;87:918-930
pubmed: 27664412
Anal Bioanal Chem. 2014 Jan;406(1):15-20
pubmed: 24232749
Conf Proc IEEE Eng Med Biol Soc. 2019 Jul;2019:1334-1337
pubmed: 31946139
Clin Chim Acta. 2015 Jun 15;446:147-55
pubmed: 25892674
Anal Chim Acta. 2017 Oct 23;991:133-141
pubmed: 29031295
Conf Proc IEEE Eng Med Biol Soc. 2019 Jul;2019:1567-1570
pubmed: 31946194
Talanta. 2015 Oct 1;143:178-183
pubmed: 26078146
J Ovarian Res. 2019 Mar 27;12(1):28
pubmed: 30917847
Enzyme Microb Technol. 2016 Jul;89:15-30
pubmed: 27233124
Anal Bioanal Chem. 2016 Oct;408(26):7289-98
pubmed: 27023219
Cancer Biol Med. 2017 Feb;14(1):9-32
pubmed: 28443200
Anal Bioanal Chem. 2018 Aug;410(21):5095-5097
pubmed: 29936572
Biosens Bioelectron. 2019 Feb 1;126:301-307
pubmed: 30445305
Biosens Bioelectron. 2018 Feb 15;100:533-540
pubmed: 28988118
Biosens Bioelectron. 2019 Jun 15;135:71-81
pubmed: 31003031
Anal Chim Acta. 2019 Sep 3;1069:117-125
pubmed: 31084737