Can low-profile double-plate osteosynthesis for olecranon fractures reduce implant removal? A retrospective multicenter study.


Journal

Journal of shoulder and elbow surgery
ISSN: 1532-6500
Titre abrégé: J Shoulder Elbow Surg
Pays: United States
ID NLM: 9206499

Informations de publication

Date de publication:
Jun 2020
Historique:
received: 29 10 2019
revised: 14 01 2020
accepted: 21 01 2020
pubmed: 15 4 2020
medline: 18 11 2020
entrez: 15 4 2020
Statut: ppublish

Résumé

Because of poor soft-tissue coverage at the proximal ulna and prominent posteriorly positioned implants, hardware removal remains the most common reason for revision surgery of olecranon fractures that were operatively treated using plate osteosynthesis. We hypothesized that low-profile double-plate osteosynthesis would reduce the number of soft tissue-related hardware removals compared with single posterior plating whereas the functional results would be comparable. This study retrospectively included patients who were treated with low-profile double-plate osteosynthesis or a posterior 2.7-/3.5-mm locking compression plate (LCP) for isolated olecranon fractures from 3 study centers. In addition to the implant removal rate, functional outcome measures (range of motion; Mayo Elbow Performance Score; Disabilities of the Arm, Shoulder and Hand score) were statistically compared. The study included 79 patients, with a mean follow-up period of 36 months (range, 24-77 months). Of these patients, 37 were treated with low-profile double-plate osteosynthesis and 42, with a 2.7-/3.5-mm LCP. The mean age was 57 years (range, 18-93 years). Range of motion after treatment with low-profile double-plate osteosynthesis and a 2.7-/3.5-mm LCP measured 129° (range, 80°-155°) and 139° (range, 100°-155°), respectively. The Mayo Elbow Performance Scores were 95 (range, 65-100) and 99 (range, 85-100), respectively (P = .028), and the Disabilities of the Arm, Shoulder and Hand scores were 5.0 (range, 0-49) and 4.6 (range, 0-28), respectively (P = .673). Hardware was removed in 32% and 50% of patients after treatment with double-plate osteosynthesis and a 2.7-/3.5-mm LCP, respectively (P = .11). Hardware removal owing to soft-tissue irritation was noted in 27% of patients after double-plate osteosynthesis and 38% after LCP treatment (P = .30). Low-profile double-plate osteosynthesis for treating olecranon fractures resulted in good clinical outcomes. However, the rate of hardware removal was not significantly reduced, and the functional results were comparable to those of common single-posterior plate osteosynthesis.

Sections du résumé

BACKGROUND BACKGROUND
Because of poor soft-tissue coverage at the proximal ulna and prominent posteriorly positioned implants, hardware removal remains the most common reason for revision surgery of olecranon fractures that were operatively treated using plate osteosynthesis. We hypothesized that low-profile double-plate osteosynthesis would reduce the number of soft tissue-related hardware removals compared with single posterior plating whereas the functional results would be comparable.
METHODS METHODS
This study retrospectively included patients who were treated with low-profile double-plate osteosynthesis or a posterior 2.7-/3.5-mm locking compression plate (LCP) for isolated olecranon fractures from 3 study centers. In addition to the implant removal rate, functional outcome measures (range of motion; Mayo Elbow Performance Score; Disabilities of the Arm, Shoulder and Hand score) were statistically compared.
RESULTS RESULTS
The study included 79 patients, with a mean follow-up period of 36 months (range, 24-77 months). Of these patients, 37 were treated with low-profile double-plate osteosynthesis and 42, with a 2.7-/3.5-mm LCP. The mean age was 57 years (range, 18-93 years). Range of motion after treatment with low-profile double-plate osteosynthesis and a 2.7-/3.5-mm LCP measured 129° (range, 80°-155°) and 139° (range, 100°-155°), respectively. The Mayo Elbow Performance Scores were 95 (range, 65-100) and 99 (range, 85-100), respectively (P = .028), and the Disabilities of the Arm, Shoulder and Hand scores were 5.0 (range, 0-49) and 4.6 (range, 0-28), respectively (P = .673). Hardware was removed in 32% and 50% of patients after treatment with double-plate osteosynthesis and a 2.7-/3.5-mm LCP, respectively (P = .11). Hardware removal owing to soft-tissue irritation was noted in 27% of patients after double-plate osteosynthesis and 38% after LCP treatment (P = .30).
DISCUSSION CONCLUSIONS
Low-profile double-plate osteosynthesis for treating olecranon fractures resulted in good clinical outcomes. However, the rate of hardware removal was not significantly reduced, and the functional results were comparable to those of common single-posterior plate osteosynthesis.

Identifiants

pubmed: 32284307
pii: S1058-2746(20)30156-7
doi: 10.1016/j.jse.2020.01.091
pii:
doi:

Types de publication

Journal Article Multicenter Study

Langues

eng

Sous-ensembles de citation

IM

Pagination

1275-1281

Informations de copyright

Copyright © 2020 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Auteurs

Alexander Ellwein (A)

Department for Orthopaedic Surgery, Medical School Hannover, Diakovere Annastift, Hannover, Germany; Department for Orthopaedic Surgery and Traumatology, Diakovere Friederikenstift, Hannover, Germany. Electronic address: alexander.ellwein@diakovere.de.

Helmut Lill (H)

Department for Orthopaedic Surgery and Traumatology, Diakovere Friederikenstift, Hannover, Germany.

Mara Warnhoff (M)

Department for Orthopaedic Surgery and Traumatology, Diakovere Friederikenstift, Hannover, Germany.

Michael Hackl (M)

Department for Orthopaedic and Trauma Surgery, University Medical Center of Cologne, Cologne, Germany.

Kilian Wegmann (K)

Department for Orthopaedic and Trauma Surgery, University Medical Center of Cologne, Cologne, Germany.

Lars-Peter Müller (LP)

Department for Orthopaedic and Trauma Surgery, University Medical Center of Cologne, Cologne, Germany.

Yves Gramlich (Y)

Department for Traumatology and Orthopaedic Surgery, BG Unfallklinik Frankfurt am Main, Frankfurt am Main, Germany.

Reinhard Hoffmann (R)

Department for Traumatology and Orthopaedic Surgery, BG Unfallklinik Frankfurt am Main, Frankfurt am Main, Germany.

Alexander Klug (A)

Department for Traumatology and Orthopaedic Surgery, BG Unfallklinik Frankfurt am Main, Frankfurt am Main, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH