Prognostic value of Charlson Comorbidity Index in the elderly with a cardioverter defibrillator implantation.
Geriatrics
Heart failure
Implantable cardioverter-defibrillator
Prevention
Sudden death
Ventricular tachycardia
Journal
International journal of cardiology
ISSN: 1874-1754
Titre abrégé: Int J Cardiol
Pays: Netherlands
ID NLM: 8200291
Informations de publication
Date de publication:
01 09 2020
01 09 2020
Historique:
received:
27
01
2020
revised:
19
03
2020
accepted:
23
03
2020
pubmed:
16
4
2020
medline:
15
5
2021
entrez:
16
4
2020
Statut:
ppublish
Résumé
Elderly patients are often underrepresented in implantable cardioverter defibrillator (ICD) trials, and ICD implantation in patients ≥75 years consequently remains controversial. We aimed to evaluate mortality, appropriate ICD therapy rates and survival gain in an elderly population after risk stratification according to the Charlson Comorbidity Index (CCI). This monocentric retrospective study included elderly ICD patients ≥75 years. They were subdivided according to their CCI score into 3 categories (0-1, 2-3 or ≥4 points). Elderly patients were matched 1:2 with younger control ICD patients on gender, type of prevention (primary or secondary) and type of device (associated cardiac resynchronization therapy or not). Between January 2009 and July 2017, 121 elderly patients (mean age 78 ± 3; 83% male) matched with 242 controls (mean age 66 ± 5) were included. At 5 year follow-up after ICD implantation, overall survival was 78%, 57%, and 29% (P = 0.002) in the elderly with a CCI score of 0-1, 2-3 and ≥4 respectively, and 72% in controls. There was no significant difference regarding ICD appropriate therapy between the 3 subgroups despite a trend towards lower rates of therapy in CCI ≥ 4 points patients (34.2%, 39.7% and 22.8% respectively; P = 0.45). Median potential survival gain after an appropriate therapy was >5, 4.7 and 1.4 years, with a CCI score of 0-1, 2-3 and ≥4 respectively (P = 0.01). Elderly patients with CCI score ≥ 4 had the lowest survival after ICD implantation and little survival gain in case of appropriate defibrillator therapy. More than age alone, the burden of comorbidities assessed by the CCI could be helpful to better select elderly patients for ICD implantation.
Sections du résumé
BACKGROUND
Elderly patients are often underrepresented in implantable cardioverter defibrillator (ICD) trials, and ICD implantation in patients ≥75 years consequently remains controversial. We aimed to evaluate mortality, appropriate ICD therapy rates and survival gain in an elderly population after risk stratification according to the Charlson Comorbidity Index (CCI).
METHODS
This monocentric retrospective study included elderly ICD patients ≥75 years. They were subdivided according to their CCI score into 3 categories (0-1, 2-3 or ≥4 points). Elderly patients were matched 1:2 with younger control ICD patients on gender, type of prevention (primary or secondary) and type of device (associated cardiac resynchronization therapy or not).
RESULTS
Between January 2009 and July 2017, 121 elderly patients (mean age 78 ± 3; 83% male) matched with 242 controls (mean age 66 ± 5) were included. At 5 year follow-up after ICD implantation, overall survival was 78%, 57%, and 29% (P = 0.002) in the elderly with a CCI score of 0-1, 2-3 and ≥4 respectively, and 72% in controls. There was no significant difference regarding ICD appropriate therapy between the 3 subgroups despite a trend towards lower rates of therapy in CCI ≥ 4 points patients (34.2%, 39.7% and 22.8% respectively; P = 0.45). Median potential survival gain after an appropriate therapy was >5, 4.7 and 1.4 years, with a CCI score of 0-1, 2-3 and ≥4 respectively (P = 0.01).
CONCLUSION
Elderly patients with CCI score ≥ 4 had the lowest survival after ICD implantation and little survival gain in case of appropriate defibrillator therapy. More than age alone, the burden of comorbidities assessed by the CCI could be helpful to better select elderly patients for ICD implantation.
Identifiants
pubmed: 32291172
pii: S0167-5273(20)30406-X
doi: 10.1016/j.ijcard.2020.03.060
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
64-69Informations de copyright
Copyright © 2020 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest Dr. Garcia received consulting fees from St. Jude Medical and Boston Scientific. Dr. Le Gal and Dr. Degand received consulting fees from Sorin Group, St. Jude Medical and Boston Scientific. The other authors have no conflict of interest.