3D whole-heart isotropic sub-millimeter resolution coronary magnetic resonance angiography with non-rigid motion-compensated PROST.


Journal

Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
ISSN: 1532-429X
Titre abrégé: J Cardiovasc Magn Reson
Pays: England
ID NLM: 9815616

Informations de publication

Date de publication:
16 04 2020
Historique:
received: 19 07 2019
accepted: 19 02 2020
entrez: 18 4 2020
pubmed: 18 4 2020
medline: 15 9 2020
Statut: epublish

Résumé

To enable free-breathing whole-heart sub-millimeter resolution coronary magnetic resonance angiography (CMRA) in a clinically feasible scan time by combining low-rank patch-based undersampled reconstruction (3D-PROST) with a highly accelerated non-rigid motion correction framework. Non-rigid motion corrected CMRA combined with 2D image-based navigators has been previously proposed to enable 100% respiratory scan efficiency in modestly undersampled acquisitions. Achieving sub-millimeter isotropic resolution with such techniques still requires prohibitively long acquisition times. We propose to combine 3D-PROST reconstruction with a highly accelerated non-rigid motion correction framework to achieve sub-millimeter resolution CMRA in less than 10 min. Ten healthy subjects and eight patients with suspected coronary artery disease underwent 4-5-fold accelerated free-breathing whole-heart CMRA with 0.9 mm Average scan times [min:s] were 6:01 ± 0:59 (healthy subjects) and 8:29 ± 1:41 (patients). In healthy subjects, vessel sharpness of the left anterior descending (LAD) and right (RCA) coronary arteries were improved with the proposed non-rigid PROST (LAD: 51.2 ± 8.8%, RCA: 61.2 ± 9.1%) in comparison to TC-PROST (LAD: 43.8 ± 5.1%, P = 0.051, RCA: 54.3 ± 8.3%, P = 0.218) and non-rigid SENSE (LAD: 46.1 ± 5.8%, P = 0.223, RCA: 56.7 ± 9.6%, P = 0.50), although differences were not statistically significant. The average visual image quality score was significantly higher for NR-PROST (LAD: 3.2 ± 0.6, RCA: 3.3 ± 0.7) compared with TC-PROST (LAD: 2.1 ± 0.6, P = 0.018, RCA: 2.0 ± 0.7, P = 0.014) and non-rigid SENSE (LAD: 2.3 ± 0.5, P = 0.008, RCA: 2.5 ± 0.7, P = 0.016). In patients, the proposed approach showed good delineation of the coronaries, in agreement with CCTA, with image quality scores and vessel sharpness similar to that of healthy subjects. We demonstrate the feasibility of combining high undersampling factors with non-rigid motion-compensated reconstruction to obtain high-quality sub-millimeter isotropic CMRA images in ~ 8 min. Validation in a larger cohort of patients with coronary artery disease is now warranted.

Sections du résumé

BACKGROUND
To enable free-breathing whole-heart sub-millimeter resolution coronary magnetic resonance angiography (CMRA) in a clinically feasible scan time by combining low-rank patch-based undersampled reconstruction (3D-PROST) with a highly accelerated non-rigid motion correction framework.
METHODS
Non-rigid motion corrected CMRA combined with 2D image-based navigators has been previously proposed to enable 100% respiratory scan efficiency in modestly undersampled acquisitions. Achieving sub-millimeter isotropic resolution with such techniques still requires prohibitively long acquisition times. We propose to combine 3D-PROST reconstruction with a highly accelerated non-rigid motion correction framework to achieve sub-millimeter resolution CMRA in less than 10 min. Ten healthy subjects and eight patients with suspected coronary artery disease underwent 4-5-fold accelerated free-breathing whole-heart CMRA with 0.9 mm
RESULTS
Average scan times [min:s] were 6:01 ± 0:59 (healthy subjects) and 8:29 ± 1:41 (patients). In healthy subjects, vessel sharpness of the left anterior descending (LAD) and right (RCA) coronary arteries were improved with the proposed non-rigid PROST (LAD: 51.2 ± 8.8%, RCA: 61.2 ± 9.1%) in comparison to TC-PROST (LAD: 43.8 ± 5.1%, P = 0.051, RCA: 54.3 ± 8.3%, P = 0.218) and non-rigid SENSE (LAD: 46.1 ± 5.8%, P = 0.223, RCA: 56.7 ± 9.6%, P = 0.50), although differences were not statistically significant. The average visual image quality score was significantly higher for NR-PROST (LAD: 3.2 ± 0.6, RCA: 3.3 ± 0.7) compared with TC-PROST (LAD: 2.1 ± 0.6, P = 0.018, RCA: 2.0 ± 0.7, P = 0.014) and non-rigid SENSE (LAD: 2.3 ± 0.5, P = 0.008, RCA: 2.5 ± 0.7, P = 0.016). In patients, the proposed approach showed good delineation of the coronaries, in agreement with CCTA, with image quality scores and vessel sharpness similar to that of healthy subjects.
CONCLUSIONS
We demonstrate the feasibility of combining high undersampling factors with non-rigid motion-compensated reconstruction to obtain high-quality sub-millimeter isotropic CMRA images in ~ 8 min. Validation in a larger cohort of patients with coronary artery disease is now warranted.

Identifiants

pubmed: 32299445
doi: 10.1186/s12968-020-00611-5
pii: 10.1186/s12968-020-00611-5
pmc: PMC7161114
doi:

Types de publication

Comparative Study Journal Article Research Support, Non-U.S. Gov't Video-Audio Media

Langues

eng

Sous-ensembles de citation

IM

Pagination

24

Subventions

Organisme : British Heart Foundation
ID : PG/18/59/33955
Pays : United Kingdom
Organisme : Department of Health
Pays : United Kingdom
Organisme : Wellcome Trust
ID : NS/ A000049/1
Pays : United Kingdom

Références

Magn Reson Med. 1997 Jan;37(1):148-52
pubmed: 8978644
Magn Reson Med. 2002 Oct;48(4):658-66
pubmed: 12353283
IEEE Trans Med Imaging. 2018 Aug;37(8):1932-1942
pubmed: 29994581
Magn Reson Med. 2018 Dec;80(6):2618-2629
pubmed: 29682783
AJR Am J Roentgenol. 1999 Apr;172(4):1061-5
pubmed: 10587147
Radiology. 1998 Oct;209(1):209-19
pubmed: 9769834
Magn Reson Med. 2014 Feb;71(2):815-22
pubmed: 23440946
Magn Reson Med. 2017 May;77(5):1874-1883
pubmed: 27174590
IEEE Trans Med Imaging. 1999 Aug;18(8):712-21
pubmed: 10534053
Circulation. 1999 Jun 22;99(24):3139-48
pubmed: 10377077
Magn Reson Med. 2014 Jun;71(6):2118-26
pubmed: 23878103
Magn Reson Med. 2005 Nov;54(5):1273-80
pubmed: 16155887
J Magn Reson Imaging. 2015 Mar;41(3):738-46
pubmed: 24573992
Radiology. 2011 Feb;258(2):340-9
pubmed: 21273518
J Magn Reson Imaging. 2002 Jun;15(6):661-71
pubmed: 12112516
Magn Reson Med. 2019 Jan;81(1):102-115
pubmed: 30058252
Magn Reson Med. 2014 Jan;71(1):67-74
pubmed: 23401157
Magn Reson Med. 2014 Mar;71(3):990-1001
pubmed: 23649942
Magn Reson Med. 2011 Dec;66(6):1541-9
pubmed: 21604297
Radiology. 1996 Jan;198(1):55-60
pubmed: 8539406
Med Phys. 2018 Jan;45(1):214-222
pubmed: 29131353
J Magn Reson Imaging. 2009 Nov;30(5):1191-6
pubmed: 19856454
Magn Reson Med. 2015 Sep;74(3):614-21
pubmed: 26172829
Magn Reson Med. 2013 Apr;69(4):1083-93
pubmed: 22648856
J Am Coll Cardiol. 2009 Jun 30;54(1):69-76
pubmed: 19555843
Magn Reson Med. 2017 May;77(5):1884-1893
pubmed: 27174673
Magn Reson Med. 2006 Apr;55(4):858-64
pubmed: 16538606
Magn Reson Med. 2009 Sep;62(3):731-8
pubmed: 19526514
Magn Reson Med. 2014 Aug;72(2):347-61
pubmed: 24006292
IEEE Trans Med Imaging. 2017 Jun;36(6):1326-1336
pubmed: 28207389
Magn Reson Med. 2016 Feb;75(2):775-88
pubmed: 25809847
Magn Reson Med. 1995 May;33(5):713-9
pubmed: 7596276
Magn Reson Med. 2016 Apr;75(4):1484-98
pubmed: 25996443
Magn Reson Med. 2011 Sep;66(3):756-67
pubmed: 21465542
Radiology. 2014 Feb;270(2):378-86
pubmed: 24471387
Magn Reson Med. 2017 May;77(5):1894-1908
pubmed: 27221073
Magn Reson Med. 2012 Feb;67(2):437-45
pubmed: 21656563
J Magn Reson Imaging. 2016 Apr;43(4):947-55
pubmed: 26451972
J Cardiovasc Magn Reson. 2017 Sep 11;19(1):68
pubmed: 28893296
Magn Reson Med. 1999 Aug;42(2):408-11
pubmed: 10440967
Magn Reson Med. 2011 May;65(5):1269-77
pubmed: 21500255
N Engl J Med. 2001 Dec 27;345(26):1863-9
pubmed: 11756576

Auteurs

Aurélien Bustin (A)

Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.

Imran Rashid (I)

Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.

Gastao Cruz (G)

Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.

Reza Hajhosseiny (R)

Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.
National Heart and Lung Institute, Imperial College London, London, UK.

Teresa Correia (T)

Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.

Radhouene Neji (R)

Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.
MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK.

Ronak Rajani (R)

Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.
Department of Cardiology, Guy's & St Thomas' Hospitals, London, UK.

Tevfik F Ismail (TF)

Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.

René M Botnar (RM)

Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK. rene.botnar@kcl.ac.uk.
Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile. rene.botnar@kcl.ac.uk.

Claudia Prieto (C)

Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.
Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH