Anterior chamber angle width, central vault and intraocular pressure changes after 12 months of Visian collamer lens implantation.

Anterior chamber angle width Central vault Implantable collamer lens Intraocular phakic lens Intraocular pressure Posterior chamber phakic lens

Journal

International ophthalmology
ISSN: 1573-2630
Titre abrégé: Int Ophthalmol
Pays: Netherlands
ID NLM: 7904294

Informations de publication

Date de publication:
Aug 2020
Historique:
received: 29 02 2020
accepted: 10 04 2020
pubmed: 22 4 2020
medline: 22 6 2021
entrez: 22 4 2020
Statut: ppublish

Résumé

To evaluate 1-year changes of vault, anterior chamber angle width (ACAW) and intraocular pressure (IOP) after the implantation of implantable collamer lens (ICL) V4c in high myopic patients. Sixty ICL V4c implantation surgeries were included. Patients underwent surgery between January 2014 and June 2017 at Ophthalmology Center Tecnolaser Clinic Vision®, Seville, Spain. All patients had a 12-month follow-up. A preoperative spherical equivalent between - 4.00 and - 15.00 D was established as inclusion criterion. ACAW and vault were measured with Pentacam single rotation Scheimpflug camera (Oculus Optikgeräte GmbH, Wetzlar, Germany). IOP was measured with CORVIS ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). One-day vault was 553.17 ± 169.80 [268-975] µm; 12-month vault was 515.67 ± 176.46 [169-950] µm (p < 0.01). Preoperative ACAW was 36.85° ± 4.60° [26.7°-46.8°]; postoperative ACAW was 25.98° ± 3.85° [16.4°-32.6°] (p < 0.01). Preoperative IOP was 15.37 ± 1.58 [12.0-18.3] mmHg, postoperative IOP was 15.61 ± 1.60 [12.0-19.0] mm Hg (p = 0.35). ICL V4c lens experienced a progressive reduction of vault after 12-month follow-up. ACAW decrease was significant between preoperative and postoperative values. We propose to include a minimum preoperative ACAW and an IOP correction factor for lens size.

Identifiants

pubmed: 32314324
doi: 10.1007/s10792-020-01381-w
pii: 10.1007/s10792-020-01381-w
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

2047-2053

Auteurs

José-María Sánchez-González (JM)

Department of Physics of Condensed Matter, Optics Area, University of Seville, Reina Mercedes Street, Seville, Spain. jsanchez80@us.es.
Department of Ophthalmology, Tecnolaser Clinic Vision, Seville, Spain. jsanchez80@us.es.

Federico Alonso-Aliste (F)

Department of Ophthalmology, Tecnolaser Clinic Vision, Seville, Spain.

Gracia Perea-Peña (G)

Department of Physics of Condensed Matter, Optics Area, University of Seville, Reina Mercedes Street, Seville, Spain.

Rahul Rachwani-Anil (R)

Department of Ophthalmology, Regional University Hospital of Malaga, Málaga, Spain.

Rafael Márquez-de-Aracena-Del-Cid (R)

Department of Surgery, Ophthalmology Area, University of Seville, Seville, Spain.

Carlos Rocha-de-Lossada (C)

Department of Ophthalmology, Regional University Hospital of Malaga, Málaga, Spain.
Department of Ophthalmology, Clinic Barcelona Hospital, Barcelona, Spain.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH