Improving the safety of resuscitative endovascular balloon occlusion of the aorta - Compliant versus semi-compliant balloon systems.


Journal

Vascular
ISSN: 1708-539X
Titre abrégé: Vascular
Pays: England
ID NLM: 101196722

Informations de publication

Date de publication:
Oct 2020
Historique:
pubmed: 2 5 2020
medline: 22 9 2020
entrez: 2 5 2020
Statut: ppublish

Résumé

Resuscitative endovascular balloon occlusion of the aorta is an alternative to resuscitative thoracotomy in non-compressible torso haemorrhage. Low-profile, compliant balloon catheter systems have been developed, which can be deployed without the need for fluoroscopy. However, concern exists for over inflation and aortic injury, especially as compliant balloon material can stretch reducing syringe feedback and limiting the effectiveness of a safety valve. An alternative material would be a semi-compliant balloon material, but its performance is unknown. The aim of this study was to compare the inflation characteristics of compliant versus semi-compliant balloon systems and to determine whether a pressure relief safety valve can be practically applied to a semi-compliant balloon catheter as a safety device. This was an ex vivo study using porcine segments of thoracic aorta. The study consisted of two phases. The first phase involved intermittent inflation of six compliant balloon and six semi-compliant balloon balloons until balloon or aortic rupture. In the second phase, six semi-compliant balloons with the pressure-relief valve set at 0.45 atmospheres were inflated in the aortas until the valve release, followed by injection with additional 30 mL. Data including pressure, volume, balloon working length, diameter and circumferential stretch ratio were collected. At failure, mean balloon volume was almost double in compliant balloon group vs semi-compliant balloon group - 49.83 mL (±23.25) and 25.16 mL (±8.93), respectively ( The inflation profile differs between balloon designs. In contrast to semi-compliant balloons, compliant balloons will accommodate more volume to mitigate increase in pressure. This does not completely eliminate the risk of over inflation. The inflation characteristics of the semi-compliant balloon permit pairing it with a safety valve, which could lead to a development of a safer balloon technology in the future.

Identifiants

pubmed: 32356682
doi: 10.1177/1708538120922106
doi:

Types de publication

Comparative Study Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

612-618

Auteurs

Marta J Madurska (MJ)

R Adams Cowley Shock Trauma Center, University of Maryland Medical Center, Baltimore, MD, USA.

Curtis Franklin (C)

Prytime Medical, Boerne, TX, USA.

Michael Richmond (M)

R Adams Cowley Shock Trauma Center, University of Maryland Medical Center, Baltimore, MD, USA.

Sakib M Adnan (SM)

Department of Surgery, Albert Einstein Healthcare Network, Philadelphia, PA, USA.

Gerard P Stansby (GP)

Department of Vascular Surgery, Freeman Hospital, Newcastle upon Tyne, UK.

Joseph M White (JM)

Division of Vascular Surgery, The Department of Surgery at the Uniformed Services University of the Health Sciences & the Walter Reed National Military Medical Center, Bethesda, MD, USA.

Jonathan J Morrison (JJ)

R Adams Cowley Shock Trauma Center, University of Maryland Medical Center, Baltimore, MD, USA.

Articles similaires

Robotic Surgical Procedures Animals Humans Telemedicine Models, Animal

Odour generalisation and detection dog training.

Lyn Caldicott, Thomas W Pike, Helen E Zulch et al.
1.00
Animals Odorants Dogs Generalization, Psychological Smell
Animals TOR Serine-Threonine Kinases Colorectal Neoplasms Colitis Mice
Animals Tail Swine Behavior, Animal Animal Husbandry

Classifications MeSH