The Impact of Novel X-Ray Systems and X-Ray System Optimization on Patient Radiation Dose Administered During Cardiac Catheterization.


Journal

The Journal of invasive cardiology
ISSN: 1557-2501
Titre abrégé: J Invasive Cardiol
Pays: United States
ID NLM: 8917477

Informations de publication

Date de publication:
Jun 2020
Historique:
pubmed: 10 5 2020
medline: 20 8 2021
entrez: 10 5 2020
Statut: ppublish

Résumé

The effect of x-ray system optimization on patient radiation dose has received limited study. We analyzed patient radiation dose in 1786 cardiac catheterization procedures (diagnostic coronary angiography and/or percutaneous coronary intervention [PCI]) performed at a single tertiary-care center before and after x-ray system optimization. After optimization, cineangiography dose-area product (DAP) dose was lower in the overall group of patients who underwent diagnostic angiography and/or PCI (1347 μGy•m² [IQR, 645-2345 μGy•m²] vs 1658 μGy•m² [IQR, 640- 2757 μGy•m²]; P=.03), as well as in the diagnostic angiography group (1795 μGy•m² [IQR, 1140-2994 μGy•m²] vs 2356 μGy•m² [IQR, 311-3576 μGy•m²]; P<.01) and PCI group (2152 μGy•m² [IQR, 1338-3477 μGy•m²] vs 2562 μGy•m² [IQR, 1681-3859 μGy•m²]; P=.02). Cineangiography DAP per exposure was also lower in the overall group (143 μGy•m² [IQR, 91-212 μGy•m²] vs 164 μGy•m² [IQR, 106-233 μGy•m²] per exposure; P<.01) and in the diagnostic angiography group (158 μGy•m² [IQR, 102-225 μGy•m²] vs 184 μGy•m² [IQR, 125-271 μGy•m²] per exposure; P<.01). After optimization, cineangiography air kerma (AK) dose (319 mGy [IQR, 197-531 mGy] vs 421 mGy [IQR, 241-600 mGy]; P=.01) and cineangiography AK per exposure (20.7 mGy [IQR, 12.9-29.0 mGy] vs 23.6 mGy [IQR, 14.1-32.9 mGy] per exposure; P=.03) were also lower in the PCI group. There was no significant change in fluoroscopy AK dose after optimization (20.7 mGy [IQR, 12.7-30.1 mGy] vs 20.4 mGy [IQR, 12.8-31.3 mGy] per minute; P=.71) and fluoroscopy DAP dose (156 μGy•m² [IQR, 101-242 μGy•m²] vs 156 μGy•m² [IQR, 102-236 μGy•m²] per minute; P=.91). X-ray system optimization was associated with lower cineangiography DAP, but similar fluoroscopy radiation dose.

Identifiants

pubmed: 32385193
pii: JIC20200509-3
pii:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

218-221

Auteurs

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH