Evaluating fidelity of CT based 3D models for Zebrafish conductive hearing system.
CT imaging
Finite element analysis
Weberian apparatus
Zebrafish
Journal
Micron (Oxford, England : 1993)
ISSN: 1878-4291
Titre abrégé: Micron
Pays: England
ID NLM: 9312850
Informations de publication
Date de publication:
08 2020
08 2020
Historique:
received:
16
12
2019
revised:
04
04
2020
accepted:
05
04
2020
pubmed:
11
5
2020
medline:
28
8
2021
entrez:
11
5
2020
Statut:
ppublish
Résumé
The zebrafish Weberian apparatus is an emerging model for human conductive hearing system. Their Weberian apparatus comprises minute bones and ligamentary links, and conducts sound pressure transmission from the gas bladder to inner ear through four pairs of Weberian ossicles along the vertebral column. We herein present a methodological study using MicroCT to image the Weberian apparatus for biomechanical and morphological analysis. The aim of this work is to evaluate computational models generated from multiple MicroCT scans with different parameters, to identify the most feasible scan combination for practical (minimized scan time) yet accurate (relative to highest resolution) biomechanical simulations. We segmented and created 3D models from CT scan image stacks at 4.64 μm, 5.05 μm, 9.30 μm and 13.08 μm voxel resolutions, respectively. Then, we used geometric morphometrics analysis to quantify inter-model shape differences, as well as a series of finite element modal and harmonic analyses to simulate auditory signal vibrations. Relative to the highest resolution and most accurate model, the Model 9.30 is closest in overall geometry and biomechanical behavior of all lower resolution models. The differences in resolution and quality of the CT substantially affect the segmentation and reconstruction process of the three-dimensional model of the ossicles, and the subsequent analyses. We conclude that scan voxel resolution is a key factor influencing outcomes of biomechanical simulations of delicate and minute structures, especially when studying the harmonic response of minute ossicles connected by ligaments using finite element modeling. Furthermore, contrast variations in CT images as determined by x-ray power and scan speed, also affect fidelity in 3D models and simulation outcomes.
Identifiants
pubmed: 32388237
pii: S0968-4328(19)30394-4
doi: 10.1016/j.micron.2020.102874
pii:
doi:
Types de publication
Evaluation Study
Journal Article
Research Support, N.I.H., Extramural
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
102874Subventions
Organisme : NIH HHS
ID : S10 OD012287
Pays : United States
Organisme : NIH HHS
ID : S10 OD025049
Pays : United States
Informations de copyright
Copyright © 2020 The Authors. Published by Elsevier Ltd.. All rights reserved.