Diagnostic accuracy of handheld electrocardiogram devices in detecting atrial fibrillation in adults in community versus hospital settings: a systematic review and meta-analysis.
atrial fibrillation
eHealth/telemedicine/mobile health
electrocardiography
Journal
Heart (British Cardiac Society)
ISSN: 1468-201X
Titre abrégé: Heart
Pays: England
ID NLM: 9602087
Informations de publication
Date de publication:
08 2020
08 2020
Historique:
received:
22
01
2020
revised:
20
03
2020
accepted:
29
03
2020
pubmed:
13
5
2020
medline:
29
6
2021
entrez:
13
5
2020
Statut:
ppublish
Résumé
With increasing use of handheld ECG devices for atrial fibrillation (AF) screening, it is important to understand their accuracy in community and hospital settings and how it differs among settings and other factors. A systematic review of eligible studies from community or hospital settings reporting the diagnostic accuracy of handheld ECG devices (ie, devices producing a rhythm strip) in detecting AF in adults, compared with a gold standard 12-lead ECG or Holter monitor, was performed. Bivariate hierarchical random-effects meta-analysis and meta-regression were performed using R V.3.6.0. The search identified 858 articles, of which 14 were included. Six studies recruited from community (n=6064 ECGs) and eight studies from hospital (n=2116 ECGs) settings. The pooled sensitivity was 89% (95% CI 81% to 94%) in the community and 92% (95% CI 83% to 97%) in the hospital. The pooled specificity was 99% (95% CI 98% to 99%) in the community and 95% (95% CI 90% to 98%) in the hospital. Accuracy of ECG devices varied: sensitivity ranged from 54.5% to 100% and specificity ranged from 61.9% to 100%. Meta-regression showed that setting (p=0.032) and ECG device type (p=0.022) significantly contributed to variations in sensitivity and specificity. The pooled sensitivity and specificity of single-lead handheld ECG devices were high. Setting and handheld ECG device type were significant factors of variation in sensitivity and specificity. These findings suggest that the setting including user training and handheld ECG device type should be carefully reviewed.
Identifiants
pubmed: 32393588
pii: heartjnl-2020-316611
doi: 10.1136/heartjnl-2020-316611
doi:
Types de publication
Journal Article
Meta-Analysis
Research Support, Non-U.S. Gov't
Systematic Review
Langues
eng
Sous-ensembles de citation
IM
Pagination
1211-1217Informations de copyright
© Author(s) (or their employer(s)) 2020. No commercial re-use. See rights and permissions. Published by BMJ.
Déclaration de conflit d'intérêts
Competing interests: None declared.