Quality performance for indirect Xa inhibitor monitoring in patients using international external quality data.


Journal

Clinical chemistry and laboratory medicine
ISSN: 1437-4331
Titre abrégé: Clin Chem Lab Med
Pays: Germany
ID NLM: 9806306

Informations de publication

Date de publication:
25 10 2020
Historique:
received: 07 02 2020
accepted: 30 04 2020
pubmed: 23 5 2020
medline: 24 8 2021
entrez: 23 5 2020
Statut: ppublish

Résumé

Objectives Chromogenic anti-activated factor X (FXa) assays are currently the "gold standard" for monitoring indirect anticoagulants. However, anti-FXa has been shown to vary according to the choice of reagents. In the present study, the performance of anti-FXa measurement was evaluated in order to gain more insight into the clinical applications. Furthermore, the longitudinal coefficient of variation (CV) was studied to investigate whether there is improvement over time. Methods Laboratory tests results were evaluated for samples spiked with unfractionated heparin (UFH), low-molecular-weight-heparin (LMWH), fondaparinux and danaparoid sodium. External quality assessment (EQA) data from multiple years were used from more than 100 laboratories. Results Comparison of the results for all methods showed significant differences in measured values between the frequently used methods (ANOVA: p < 0.001). The largest differences were observed for LMWH and UFH measurements. These differences may be caused by differences in method composition, such as the addition of dextran sulphate. Substantial interlaboratory variation in anti-FXa monitoring was observed for all parameters, particularly at low concentrations. Our results showed that below 0.35 IU/mL, the CVs for UFH and LMWH increase dramatically and results below this limit should be used with caution. Conclusions Our study demonstrates that the choice of the anti-FXa method is particularly important for UFH and LMWH measurement. The variation in measurements may have an effect on clinical implications, such as therapeutic ranges. Furthermore, the longitudinal EQA data demonstrated a constant performance and, in at least 50% of the cases, improvement in the CV% of the anti-Xa results over time.

Identifiants

pubmed: 32441664
doi: 10.1515/cclm-2020-0130
pii: cclm-2020-0130
doi:

Substances chimiques

Factor Xa Inhibitors 0
Heparin, Low-Molecular-Weight 0
Dermatan Sulfate 24967-94-0
Chondroitin Sulfates 9007-28-7
Heparitin Sulfate 9050-30-0
danaparoid BI6GY4U9CW
Fondaparinux J177FOW5JL

Types de publication

Journal Article Multicenter Study

Langues

eng

Sous-ensembles de citation

IM

Pagination

1921-1930

Références

Garcia DA, Baglin TP, Weitz JI, Samama MM. Parenteral anticoagulants: antithrombotic therapy and prevention of thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines. Chest 2012;141:e24S–43S.
Harenberg J. Is laboratory monitoring of low-molecular-weight heparin therapy necessary? Yes. J Thromb Haemost 2004;2:547–50.
Bounameaux H, de Moerloose P. Is laboratory monitoring of low-molecular-weight heparin therapy necessary? No. J Thromb Haemost 2004;2:551–4.
Shojania AM. More on: is laboratory monitoring of low-molecular-weight heparin necessary? J Thromb Haemost 2004;2:2276–7.
Bates SM, Greer IA, Middeldorp S, Veenstra DL, Prabulos AM, Vandvik PO. VTE, thrombophilia, antithrombotic therapy, and pregnancy: antithrombotic therapy and prevention of thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines. Chest 2012;141:e691S–736S.
Monagle P, Chan AK, Goldenberg NA, Ichord RN, Journeycake JM, Nowak-Gottl U, et al. Antithrombotic therapy in neonates and children: antithrombotic therapy and prevention of thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines. Chest 2012;141:e737S–801S.
Babin JL, Traylor KL, Witt DM. Laboratory monitoring of low-molecular-weight heparin and fondaparinux. Semin Thromb Hemost 2017;43:261–9.
Linkins LA, Dans AL, Moores LK, Bona R, Davidson BL, Schulman S, et al. Treatment and prevention of heparin-induced thrombocytopenia: antithrombotic therapy and prevention of thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines. Chest 2012;141:e495S–530S.
Ignjatovic V, Summerhayes R, Gan A, Than J, Chan A, Cochrane A, et al. Monitoring unfractionated heparin (UFH) therapy: which Anti-Factor Xa assay is appropriate? Thromb Res 2007;120:347–51.
Kitchen S, Theaker J, Preston FE. Monitoring unfractionated heparin therapy: relationship between eight anti-Xa assays and a protamine titration assay. Blood Coagul Fibrinolysis 2000;11:137–44.
Kovacs MJ, Keeney M, MacKinnon K, Boyle E. Three different chromogenic methods do not give equivalent anti-Xa levels for patients on therapeutic low molecular weight heparin (dalteparin) or unfractionated heparin. Clin Lab Haematol 1999;21:55–60.
Kitchen S, Iampietro R, Woolley AM, Preston FE. Anti Xa monitoring during treatment with low molecular weight heparin or danaparoid: inter-assay variability. Thromb Haemost 1999;82:1289–93.
Harris LF, O’Brien A, Castro-Lopez V, O’Donnell JS, Killard AJ. Comparison of the anticoagulant response of a novel fluorogenic anti-FXa assay with two commercial anti-FXa chromogenic assays. Thromb Res 2011;128:e166–70.
Favaloro EJ, Bonar R, Aboud M, Low J, Sioufi J, Wheeler M, et al. How useful is the monitoring of (low molecular weight) heparin therapy by anti-Xa assay? A laboratory perspective. Lab Hematol 2005;11:157–62.
Cuker A, Raby A, Moffat KA, Flynn G, Crowther MA. Interlaboratory variation in heparin monitoring: lessons from the quality management program of Ontario coagulation surveys. Thromb Haemost 2010;104:837–44.
Bonar RA, Favaloro EJ, Marsden K. External quality assurance for heparin monitoring. Semin Thromb Hemost 2012;38:632–9.
ISO13528:2015. Statistical methods for use in proficiency testing by interlaboratory comparisons.
Buttner J. The need for accuracy in laboratory medicine. Eur J Clin Chem Clin Biochem 1995;33:981–8.
Teoh KH, Young E, Bradley CA, Hirsh J. Heparin binding proteins. Contribution to heparin rebound after cardiopulmonary bypass. Circulation 1993;88:II420–5.
Lyon SG, Lasser EC, Stein R. Modification of an amidolytic heparin assay to express protein-bound heparin and to correct for the effect of antithrombin III concentration. Thromb Haemost 1987;58:884–7.
Gehrie E, Laposata M. Test of the month: the chromogenic antifactor Xa assay. Am J Hematol 2012;87:194–6.
Favaloro EJ, Bonar R, Sioufi J, Wheeler M, Low J, Aboud M, et al. An international survey of current practice in the laboratory assessment of anticoagulant therapy with heparin. Pathology 2005;37:234–8.
Greene LA, Law C, Jung M, Walton S, Ignjatovic V, Monagle P, et al. Lack of anti-factor Xa assay standardization results in significant low molecular weight heparin (enoxaparin) dose variation in neonates and children. J Thromb Haemost 2014;12:1554–7.
Jennings I, Kitchen D, Kitchen S, Woods T, Walker I. The importance of commutability in material used for quality control purposes. Int J Lab Hematol 2019;41:39–45.

Auteurs

Martine J Hollestelle (MJ)

External Quality Control for Assays and Tests (ECAT) Foundation, Voorschoten, The Netherlands.

Felix J M van der Meer (FJM)

Department of Thrombosis and Hemostasis, Leiden University Medical Center, Leiden, The Netherlands.

Piet Meijer (P)

External Quality Control for Assays and Tests (ECAT) Foundation, Voorschoten, The Netherlands.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH