Transjugular intrahepatic portosystemic shunt placement: portal vein puncture guided by 3D/2D image registration of contrast-enhanced multi-detector computed tomography and fluoroscopy.
Image registration
Image-guided therapy
Operator experience
Transjugular intrahepatic portosystemic shunt
Venous intervention
Journal
Abdominal radiology (New York)
ISSN: 2366-0058
Titre abrégé: Abdom Radiol (NY)
Pays: United States
ID NLM: 101674571
Informations de publication
Date de publication:
11 2020
11 2020
Historique:
pubmed:
27
5
2020
medline:
22
6
2021
entrez:
27
5
2020
Statut:
ppublish
Résumé
To assess the technical feasibility, success rate, puncture complications and procedural characteristics of transjugular intrahepatic portosystemic shunt (TIPS) placement using a three-dimensional vascular map (3D-VM) overlay based on image registration of pre-procedural contrast-enhanced (CE) multi-detector computed tomography (MDCT) for portal vein puncture guidance. Overall, 27 consecutive patients (59 ± 9 years, 18male) with portal hypertension undergoing elective TIPS procedure were included. TIPS was guided by CE-MDCT overlay after image registration based on fluoroscopic images. A 3D-VM of the hepatic veins and the portal vein was created based on the pre-procedural CE-MDCT and superimposed on fluoroscopy in real-time. Procedural characteristics as well as hepatic vein catheterization time (HVCT), puncture time (PT), overall procedural time (OPT), fluoroscopy time (FT) and the dose area product (DAP) were evaluated. Thereafter, HVCT, PT, OPT and FT using 3D-VM (61 ± 9 years, 14male) were compared to a previous using classical fluoroscopic guidance (53 ± 9 years, 21male) for two interventional radiologist with less than 3 years of experience in TIPS placement. All TIPS procedure using of 3D/2D image registered 3D-VM were successful with a significant reduction of the PSG (p < 0.0001). No clinical significant complication occurred. HVCT was 14 ± 11 min, PT was 14 ± 6 min, OPT was 64 ± 29 min, FT was 21 ± 12 min and DAP was 107.48 ± 93.84 Gy cm TIPS placement applying registration-based CE-MDCT vessel information for puncture guidance is feasible and safe. It has the potential to improve hepatic vein catherization, portal vein puncture and radiation exposure.
Sections du résumé
BACKGROUND
To assess the technical feasibility, success rate, puncture complications and procedural characteristics of transjugular intrahepatic portosystemic shunt (TIPS) placement using a three-dimensional vascular map (3D-VM) overlay based on image registration of pre-procedural contrast-enhanced (CE) multi-detector computed tomography (MDCT) for portal vein puncture guidance.
MATERIALS AND METHODS
Overall, 27 consecutive patients (59 ± 9 years, 18male) with portal hypertension undergoing elective TIPS procedure were included. TIPS was guided by CE-MDCT overlay after image registration based on fluoroscopic images. A 3D-VM of the hepatic veins and the portal vein was created based on the pre-procedural CE-MDCT and superimposed on fluoroscopy in real-time. Procedural characteristics as well as hepatic vein catheterization time (HVCT), puncture time (PT), overall procedural time (OPT), fluoroscopy time (FT) and the dose area product (DAP) were evaluated. Thereafter, HVCT, PT, OPT and FT using 3D-VM (61 ± 9 years, 14male) were compared to a previous using classical fluoroscopic guidance (53 ± 9 years, 21male) for two interventional radiologist with less than 3 years of experience in TIPS placement.
RESULTS
All TIPS procedure using of 3D/2D image registered 3D-VM were successful with a significant reduction of the PSG (p < 0.0001). No clinical significant complication occurred. HVCT was 14 ± 11 min, PT was 14 ± 6 min, OPT was 64 ± 29 min, FT was 21 ± 12 min and DAP was 107.48 ± 93.84 Gy cm
CONCLUSION
TIPS placement applying registration-based CE-MDCT vessel information for puncture guidance is feasible and safe. It has the potential to improve hepatic vein catherization, portal vein puncture and radiation exposure.
Identifiants
pubmed: 32451673
doi: 10.1007/s00261-020-02589-1
pii: 10.1007/s00261-020-02589-1
pmc: PMC7593285
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
3934-3943Commentaires et corrections
Type : ErratumIn
Références
Fidelman N, Kwan SW, LaBerge JM, et al (2012) The transjugular intrahepatic portosystemic shunt: an update. AJR Am J Roentgenol 199:746–755. https://doi.org/10.2214/AJR.12.9101
doi: 10.2214/AJR.12.9101
pubmed: 22997364
García-Pagán JC, Caca K, Bureau C, et al (2010) Early use of TIPS in patients with cirrhosis and variceal bleeding. N Engl J Med 362:2370–2379. https://doi.org/10.1056/NEJMoa0910102
doi: 10.1056/NEJMoa0910102
pubmed: 20573925
Rössle M, Deibert P, Haag K, et al (1997) Randomised trial of transjugular-intrahepatic-portosystemic shunt versus endoscopy plus propranolol for prevention of variceal rebleeding. Lancet 349:1043–1049. https://doi.org/10.1016/s0140-6736(96)08189-5
doi: 10.1016/s0140-6736(96)08189-5
pubmed: 9107241
Lo G-H, Liang H-L, Chen W-C, et al (2007) A prospective, randomized controlled trial of transjugular intrahepatic portosystemic shunt versus cyanoacrylate injection in the prevention of gastric variceal rebleeding. Endoscopy 39:679–685. https://doi.org/10.1055/s-2007-966591
doi: 10.1055/s-2007-966591
pubmed: 17661241
Sanyal AJ (2005) Pros and cons of TIPS for refractory ascites. Journal of Hepatology 43:924–925. https://doi.org/10.1016/j.jhep.2005.09.006
doi: 10.1016/j.jhep.2005.09.006
pubmed: 16246451
Rösch J, Hanafee WN, Snow H (1969) Transjugular portal venography and radiologic portacaval shunt: an experimental study. Radiology 92:1112–1114. https://doi.org/10.1148/92.5.1112
doi: 10.1148/92.5.1112
pubmed: 5771827
Rössle M, Haag K, Ochs A, et al (1994) The transjugular intrahepatic portosystemic stent-shunt procedure for variceal bleeding. N Engl J Med 330:165–171. https://doi.org/10.1056/NEJM199401203300303
doi: 10.1056/NEJM199401203300303
pubmed: 8264738
Boyer TD, Haskal ZJ, American Association for the Study of Liver Diseases (2005) The role of transjugular intrahepatic portosystemic shunt in the management of portal hypertension. Hepatology 41:386–400. https://doi.org/10.1002/hep.20559
doi: 10.1002/hep.20559
Gaba RC, Khiatani VL, Knuttinen MG, et al (2011) Comprehensive Review of TIPS Technical Complications and How to Avoid Them. American Journal of Roentgenology 196:675–685. https://doi.org/10.2214/AJR.10.4819
doi: 10.2214/AJR.10.4819
pubmed: 21343513
Bai M (2014) Shunting branch of portal vein and stent position predict survival after transjugular intrahepatic portosystemic shunt. WJG 20:774. https://doi.org/10.3748/wjg.v20.i3.774
doi: 10.3748/wjg.v20.i3.774
pubmed: 24574750
Marquardt S, Rodt T, Rosenthal H, et al (2015) Impact of Anatomical, Procedural, and Operator Skill Factors on the Success and Duration of Fluoroscopy-Guided Transjugular Intrahepatic Portosystemic Shunt. Cardiovasc Intervent Radiol 38:903–912. https://doi.org/10.1007/s00270-014-1035-6
doi: 10.1007/s00270-014-1035-6
pubmed: 25501265
Ketelsen D, Groezinger G, Maurer M, et al (2016) Three-dimensional C-arm CT-guided transjugular intrahepatic portosystemic shunt placement: Feasibility, technical success and procedural time. Eur Radiol 26:4277–4283. https://doi.org/10.1007/s00330-016-4340-4
doi: 10.1007/s00330-016-4340-4
pubmed: 27048535
Buechter M, Manka P, Gerken G, et al (2018) Transjugular Intrahepatic Portosystemic Shunt in Patients with Portal Hypertension: Patency Depends on Coverage and Interventionalist’s Experience. Dig Dis 36:218–227. https://doi.org/10.1159/000486030
doi: 10.1159/000486030
pubmed: 29316565
Kwan SW, Fidelman N, Durack JC, et al (2011) Rex shunt preoperative imaging: diagnostic capability of imaging modalities. PLoS ONE 6:e22222. https://doi.org/10.1371/journal.pone.0022222
doi: 10.1371/journal.pone.0022222
pubmed: 21765956
pmcid: 3134475
Raza SA, Walser E, Hernandez A, et al (2006) Transhepatic puncture of portal and hepatic veins for TIPS using a single-needle pass under sonographic guidance. AJR Am J Roentgenol 187:W87-91. https://doi.org/10.2214/AJR.05.1342
doi: 10.2214/AJR.05.1342
pubmed: 16794144
Farsad K, Fuss C, Kolbeck KJ, et al (2012) Transjugular intrahepatic portosystemic shunt creation using intravascular ultrasound guidance. J Vasc Interv Radiol 23:1594–1602. https://doi.org/10.1016/j.jvir.2012.08.023
doi: 10.1016/j.jvir.2012.08.023
pubmed: 23099001
Adamus R, Pfister M, Loose RWR (2009) Enhancing transjugular intrahepatic portosystemic shunt puncture by using three-dimensional path planning based on the back projection of two two-dimensional portographs. Radiology 251:543–547. https://doi.org/10.1148/radiol.2512080423
doi: 10.1148/radiol.2512080423
pubmed: 19401578
Tsauo J, Luo X, Ye L, Li X (2015) Three-Dimensional Path Planning Software-Assisted Transjugular Intrahepatic Portosystemic Shunt: A Technical Modification. Cardiovasc Intervent Radiol 38:742–746. https://doi.org/10.1007/s00270-014-0931-0
doi: 10.1007/s00270-014-0931-0
pubmed: 24934737
Rouabah K, Varoquaux A, Caporossi JM, et al (2016) Image fusion-guided portal vein puncture during transjugular intrahepatic portosystemic shunt placement. Diagn Interv Imaging 97:1095–1102. https://doi.org/10.1016/j.diii.2016.06.015
doi: 10.1016/j.diii.2016.06.015
pubmed: 27503116
Tacher V, Petit A, Derbel H, et al (2017) Three-dimensional Image Fusion Guidance for Transjugular Intrahepatic Portosystemic Shunt Placement. Cardiovasc Intervent Radiol 40:1732–1739. https://doi.org/10.1007/s00270-017-1699-9
doi: 10.1007/s00270-017-1699-9
pubmed: 28516271
Böning G, Lüdemann WM, Chapiro J, et al (2018) Clinical Experience with Real-Time 3-D Guidance Based on C-Arm-Acquired Cone-Beam CT (CBCT) in Transjugular Intrahepatic Portosystemic Stent Shunt (TIPSS) Placement. Cardiovasc Intervent Radiol 41:1035–1042. https://doi.org/10.1007/s00270-018-1877-4
doi: 10.1007/s00270-018-1877-4
pubmed: 29541837
Chivot C, Robert B, Bouzerar R, et al (2018) 3D C-Arm cone beam CT for targeting the portal vein during TIPS: Initial clinical experience. European Journal of Radiology 106:20–25. https://doi.org/10.1016/j.ejrad.2018.06.025
doi: 10.1016/j.ejrad.2018.06.025
pubmed: 30150046
Luo X, Wang X, Zhao Y, et al (2017) Real-Time 3D CT Image Guidance for Transjugular Intrahepatic Portosystemic Shunt Creation Using Preoperative CT: A Prospective Feasibility Study of 20 Patients. American Journal of Roentgenology 208:W11–W16. https://doi.org/10.2214/AJR.15.15210
doi: 10.2214/AJR.15.15210
pubmed: 27786554
Luo X, Wang X, Yu J, et al (2018) Transjugular intrahepatic portosystemic shunt creation: three-dimensional roadmap versus CO2 wedged hepatic venography. Eur Radiol 28:3215–3220. https://doi.org/10.1007/s00330-018-5316-3
doi: 10.1007/s00330-018-5316-3
pubmed: 29460071
Gerbes AL, Labenz J, Appenrodt B, et al (2019) Aktualisierte S2k-Leitlinie der Deutschen Gesellschaft für Gastroenterologie, Verdauungs- und Stoffwechselkrankheiten (DGVS) „Komplikationen der Leberzirrhose“: AWMF-Nr.: 021-017. Z Gastroenterol 57:611–680. https://doi.org/10.1055/a-0873-4658
doi: 10.1055/a-0873-4658
pubmed: 31060080
Angeli P, Bernardi M, Villanueva C, et al (2018) EASL Clinical Practice Guidelines for the management of patients with decompensated cirrhosis. Journal of Hepatology 69:406–460. https://doi.org/10.1016/j.jhep.2018.03.024
doi: 10.1016/j.jhep.2018.03.024
Choi J-Y, Lee J-M, Sirlin CB (2014) CT and MR imaging diagnosis and staging of hepatocellular carcinoma: part I. Development, growth, and spread: key pathologic and imaging aspects. Radiology 272:635–654. https://doi.org/10.1148/radiol.14132361
doi: 10.1148/radiol.14132361
pubmed: 25153274
pmcid: 4263631
Choi J-Y, Lee J-M, Sirlin CB (2014) CT and MR Imaging Diagnosis and Staging of Hepatocellular Carcinoma: Part II. Extracellular Agents, Hepatobiliary Agents, and Ancillary Imaging Features. Radiology 273:30–50. https://doi.org/10.1148/radiol.14132362
doi: 10.1148/radiol.14132362
pubmed: 25247563
pmcid: 4263770
Hinrichs JB, Renne J, Hoeper MM, et al (2016) Balloon pulmonary angioplasty: applicability of C-Arm CT for procedure guidance. Eur Radiol 26:4064–4071. https://doi.org/10.1007/s00330-016-4280-z
doi: 10.1007/s00330-016-4280-z
pubmed: 26905868
Khalilzadeh O, Baerlocher MO, Shyn PB, et al (2017) Proposal of a New Adverse Event Classification by the Society of Interventional Radiology Standards of Practice Committee. Journal of Vascular and Interventional Radiology 28:1432-1437.e3. https://doi.org/10.1016/j.jvir.2017.06.019
doi: 10.1016/j.jvir.2017.06.019
pubmed: 28757285
Miller DL, Kwon D, Bonavia GH (2009) Reference Levels for Patient Radiation Doses in Interventional Radiology: Proposed Initial Values for U.S. Practice. Radiology 253:753–764. https://doi.org/10.1148/radiol.2533090354
doi: 10.1148/radiol.2533090354
pubmed: 19789226
Ambrosini P, Ruijters D, Niessen WJ, et al (2015) Continuous roadmapping in liver TACE procedures using 2D-3D catheter-based registration. Int J Comput Assist Radiol Surg 10:1357–1370. https://doi.org/10.1007/s11548-015-1218-x
doi: 10.1007/s11548-015-1218-x
pubmed: 25985880
pmcid: 4563001
Schott P, Katoh M, Fischer N, Freyhardt P (2019) Radiation Dose in Prostatic Artery Embolization Using Cone-Beam CT and 3D Roadmap Software. J Vasc Interv Radiol 30:1452–1458. https://doi.org/10.1016/j.jvir.2019.04.040
doi: 10.1016/j.jvir.2019.04.040
pubmed: 31371137
Leger T, Tacher V, Majewski M, et al (2019) Image Fusion Guidance for In Situ Laser Fenestration of Aortic Stent graft for Endovascular Repair of Complex Aortic Aneurysm: Feasibility, Efficacy and Overall Functional Success. Cardiovasc Intervent Radiol 42:1371–1379. https://doi.org/10.1007/s00270-019-02231-8
doi: 10.1007/s00270-019-02231-8
pubmed: 31087148