3D Motion Estimation of Left Ventricular Dynamics Using MRI and Track-to-Track Fusion.
Multiview fusion
cardiac motion estimation
magnetic resonance imaging
nonlinear dynamic state estimation
regional wall motion abnormality
Journal
IEEE journal of translational engineering in health and medicine
ISSN: 2168-2372
Titre abrégé: IEEE J Transl Eng Health Med
Pays: United States
ID NLM: 101623153
Informations de publication
Date de publication:
2020
2020
Historique:
received:
21
11
2019
revised:
26
03
2020
accepted:
15
04
2020
entrez:
30
5
2020
pubmed:
30
5
2020
medline:
30
5
2020
Statut:
epublish
Résumé
This study investigates the estimation of three dimensional (3D) left ventricular (LV) motion using the fusion of different two dimensional (2D) cine magnetic resonance (CMR) sequences acquired during routine imaging sessions. Although standard clinical cine CMR data is inherently 2D, the actual underlying LV dynamics lies in 3D space and cannot be captured entirely using single 2D CMR image sequences. By utilizing the image information from various short-axis and long-axis image sequences, the proposed method intends to estimate the dynamic state vectors consisting of the position and velocity information of the myocardial borders in 3D space. The proposed method comprises two main components: tracking myocardial points in 2D CMR sequences and fusion of multiple trajectories correspond to the tracked points. The tracking which yields the set of corresponding temporal points representing the myocardial points is performed using a diffeomorphic nonrigid image registration approach. The trajectories obtained from each cine CMR sequence is then fused with the corresponding trajectories from other CMR views using an unscented Kalman smoother (UKS) and a track-to-track fusion algorithm. We evaluated the proposed method by comparing the results against CMR imaging with myocardial tagging. We report a quantitative performance analysis by projecting the state vector estimates we obtained onto 2D tagged CMR images acquired from the same subjects and comparing them against harmonic phase estimates. The proposed algorithm yielded a competitive performance with a mean root mean square error of 1.3±0.5 pixels (1.8±0.6 mm) evaluated over 118 image sequences acquired from 30 subjects. This study demonstrates that fusing the information from short and long-axis views of CMR improves the accuracy of cardiac tissue motion estimation. Clinical Impact: The proposed method demonstrates that the fusion of tissue tracking information from long and short-axis views improves the binary classification of the automated regional function assessment.
Identifiants
pubmed: 32467779
doi: 10.1109/JTEHM.2020.2989390
pii: 1800209
pmc: PMC7247756
doi:
Types de publication
Journal Article
Langues
eng
Pagination
1800209Références
Med Image Comput Comput Assist Interv. 2010;13(Pt 1):409-17
pubmed: 20879257
Med Image Anal. 2012 Jan;16(1):339-50
pubmed: 22000567
IEEE Trans Biomed Eng. 2005 Aug;52(8):1425-35
pubmed: 16119238
IEEE Trans Med Imaging. 2009 Apr;28(4):595-607
pubmed: 19211347
IEEE Trans Inf Technol Biomed. 2010 Jul;14(4):1106-13
pubmed: 20501348
IEEE Trans Med Imaging. 2004 Oct;23(10):1245-50
pubmed: 15493692
J Magn Reson Imaging. 2008 May;27(5):1019-27
pubmed: 18425823
Radiology. 1982 Apr;143(1):29-36
pubmed: 7063747
IEEE Trans Med Imaging. 2014 Feb;33(2):481-94
pubmed: 24184708
Circulation. 2007 Feb 6;115(5):654-7
pubmed: 17283280
IEEE Trans Med Imaging. 2010 Mar;29(3):733-45
pubmed: 20199911
Magn Reson Med. 1999 Dec;42(6):1048-60
pubmed: 10571926
IEEE Trans Biomed Eng. 2010 Aug;57(8):2001-10
pubmed: 20501346
Med Image Anal. 2011 Apr;15(2):169-84
pubmed: 21216179
Med Image Anal. 2013 Apr;17(3):311-24
pubmed: 23375719
IEEE Trans Med Imaging. 2007 Sep;26(9):1136-53
pubmed: 17896588
Med Image Comput Comput Assist Interv. 2010;13(Pt 1):340-8
pubmed: 20879249
IEEE Trans Med Imaging. 2010 Jan;29(1):1-11
pubmed: 19369149
Circulation. 2002 Jan 29;105(4):539-42
pubmed: 11815441