Influence of different urinary bladder filling levels and controlling regions of interest selection on deformable image registration algorithms.

ANACONDA Controlling ROIs Deformable image registration Hybrid deformation algorithm

Journal

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
ISSN: 1724-191X
Titre abrégé: Phys Med
Pays: Italy
ID NLM: 9302888

Informations de publication

Date de publication:
27 May 2020
Historique:
received: 16 03 2020
revised: 01 05 2020
accepted: 12 05 2020
pubmed: 31 5 2020
medline: 31 5 2020
entrez: 31 5 2020
Statut: aheadofprint

Résumé

Evaluation of Raystation ANAtomically CONstrained Deformation Algorithm (ANACONDA) performance to different urinary bladder filling levels in male pelvis anatomic site varying the controlling Regions Of Interest (ROIs). Different image datasets were obtained with ImSimQA (Oncology System Limited, Shrewsbury, UK) to evaluate ANACONDA performances (RaySearch Laboratories, Stockholm, Sweden). Deformation vector fields were applied to a synthetic man pelvis and a real patient computed tomography (CT) dataset (reference CTs) resulting in deformed CTs (target CTs) with various bladder filling levels. Different deformable image registrations (DIRs) were generated between each target CTs and reference CTs varying the controlling ROIs subset. Deformed ROIs were mapped from target CT to reference CT and then compared to reference ROIs. Evaluation was performed by Dice Similarity Coefficient (DSC), Correlation Coefficient (CC), Mean Distance to Agreement (MDA), maximum Distance to Agreement (maxDA) and with the introduction of global DSC (global_DSC) and global CC (global_CC) parameters. In both synthetic and real patient CT cases, DSC scored less than 0.75 and MDA greater than 3 mm when no ROIs or only bladder were exploited as controlling ROI. DSC and CC increased by increasing the number of controlling ROIs selected whereas, an opposite behavior was observed for MDA and maxDA. ANACONDA performances can be influenced by bladder filling fluctuation if no controlling ROIs are selected. Global_DSC and global_CC are useful parameters to quantitatively compare DIR algorithms. DIR performances improve by increasing the number of controlling ROIs selected, reaching a saturation level after a defined ROIs subset selection.

Identifiants

pubmed: 32473519
pii: S1120-1797(20)30120-4
doi: 10.1016/j.ejmp.2020.05.016
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

19-25

Informations de copyright

Copyright © 2020 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Auteurs

Chiara Romanò (C)

Unit of Medical Physics, IEO, European Institute of Oncology IRCCS, Via Ripamonti 435, I 20132 Milan, Italy; Department of Physics, University of Milan, Via Festa del Perdono, 7, 20122 Milan, Italy. Electronic address: chia.romano53@gmail.com.

Paolo De Marco (P)

Unit of Medical Physics, IEO, European Institute of Oncology IRCCS, Via Ripamonti 435, I 20132 Milan, Italy.

Sara Trivellato (S)

Unit of Medical Physics, IEO, European Institute of Oncology IRCCS, Via Ripamonti 435, I 20132 Milan, Italy.

Delia Ciardo (D)

Division of Radiation Oncology, IEO, European Institute of Oncology IRCCS, Via Ripamonti 435, I 20132 Milan, Italy.

Stefania Comi (S)

Unit of Medical Physics, IEO, European Institute of Oncology IRCCS, Via Ripamonti 435, I 20132 Milan, Italy.

Giulia Marvaso (G)

Division of Radiation Oncology, IEO, European Institute of Oncology IRCCS, Via Ripamonti 435, I 20132 Milan, Italy.

Giulia Riva (G)

Division of Radiation Oncology, IEO, European Institute of Oncology IRCCS, Via Ripamonti 435, I 20132 Milan, Italy.

Barbara Alicja Jereczek-Fossa (BA)

Division of Radiation Oncology, IEO, European Institute of Oncology IRCCS, Via Ripamonti 435, I 20132 Milan, Italy; Department of Oncology and Hemato-oncology, University of Milan, Via Festa del Perdono, 7, 20122 Milan, Italy.

Roberto Orecchia (R)

Scientific Directorate, IEO, European Institute of Oncology IRCCS, Via Ripamonti 435, I 20132 Milan, Italy.

Federica Cattani (F)

Unit of Medical Physics, IEO, European Institute of Oncology IRCCS, Via Ripamonti 435, I 20132 Milan, Italy.

Classifications MeSH